998 resultados para Acrylic resin denture teeth


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tanning industry generates a high quantity of solid wastes. Therefore, there is a need to create valorization [added value] options for these wastes. The main objective of the present work was to study the effect of protein hydrolysates (HP) prepared from fleshings on leather dyeing. During previous studies it was found that the application of HP products, obtained from fleshings, in leather retannage intensified the colour of crust leather. In this work the CIELAB colour system was used to evaluate the effect of HP on retannage processes. The main conclusions of this study were: (i) HP can be used instead of a dicyanodiamide resin (Fortan DC) if the colour parameters of the standard procedure are to be maintained, and (ii) the replacement of an acrylic resin (Fortan A40) by glutaraldehyde-modified HP (GHP) results in a darker skin, and can therefore be interesting for the reduction of the quantity of dye used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of joint immobilization on morphometric parameters and glycogen content of soleus muscle treated with clenbuterol. Male Wistar (3-4 months old) rats were divided into 4 groups (N = 6 for each group): control, clenbuterol, immobilized, and immobilized treated with clenbuterol. Immobilization was performed with acrylic resin orthoses and 10 µg/kg body weight clenbuterol was administered subcutaneously for 7 days. The following parameters were measured the next day on soleus muscle: weight, glycogen content, cross-sectional area, and connective tissue content. The clenbuterol group showed an increase in glycogen (81.6%, 0.38 ± 0.09 vs 0.69 ± 0.06 mg/100 g; P < 0.05) without alteration in weight, cross-sectional area or connective tissue compared with the control group. The immobilized group showed a reduction in muscle weight (34.2%, 123.5 ± 5.3 vs 81.3 ± 4.6 mg; P < 0.05), glycogen content (31.6%, 0.38 ± 0.09 vs 0.26 ± 0.05 mg/100 mg; P < 0.05) and cross-sectional area (44.1%, 2574.9 ± 560.2 vs 1438.1 ± 352.2 µm²; P < 0.05) and an increase in connective tissue (216.5%, 8.82 ± 3.55 vs 27.92 ± 5.36%; P < 0.05). However, the immobilized + clenbuterol group showed an increase in weight (15.9%; 81.3 ± 4.6 vs 94.2 ± 4.3 mg; P < 0.05), glycogen content (92.3%, 0.26 ± 0.05 vs 0.50 ± 0.17 mg/100 mg; P < 0.05), and cross-sectional area (19.9%, 1438.1 ± 352.2 vs 1724.8 ± 365.5 µm²; P < 0.05) and a reduction in connective tissue (52.2%, 27.92 ± 5.36 vs 13.34 ± 6.86%; P < 0.05). Statistical analysis was performed using Kolmogorov-Smirnov and homoscedasticity tests. For the muscle weight and muscle glycogen content, two-way ANOVA and the Tukey test were used. For the cross-sectional area and connective tissue content, Kruskal-Wallis and Tukey tests were used. This study emphasizes the importance of anabolic pharmacological protection during immobilization to minimize skeletal muscle alterations resulting from disuse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El glifosat, N-(fosfonometil) glicina, és un dels herbicides més utilitzats arreu del món a causa de la seva baixa toxicitat i al seu ampli espectre d'aplicació. A conseqüència del gran ús que se'n fa, és necessari monitoritzar aquest compost i el seu principal metabòlit, l'àcid aminometilfosfònic (AMPA), en el medi ambient. S'han descrit diversos mètodes instrumentals basats en cromatografia de gasos (GC) i de líquids (HPLC), sent aquesta darrera l'opció més favorable a causa del caràcter polar dels anàlits. Per assolir nivells de concentració baixos cal, però, la preconcentració dels anàlits. En aquest treball s'estudien diferents alternatives amb aquest objectiu. S'ha avaluat la tècnica de membrana líquida suportada (SLM) on la membrana consisteix en una dissolució orgànica, que conté un transportador (en el nostre cas, un bescanviador d'anions comercial, Aliquat 336), que impregna un suport polimèric microporós que se situa entre dues solucions aquoses: la de càrrega, que conté els anàlits inicialment, i la receptora, on es retenen els anàlits després del seu transport a través de la membrana. Les condicions d'extracció més adequades s'obtenen treballant en medi bàsic amb NaOH on els anàlits estan en forma aniònica i les majors recuperacions s'obtenen amb HCl 0,1 M o NaCl 0,5 M, la qual cosa indica que l'ió clorur és la força impulsora del transport. Un cop dissenyat el sistema, es duen a terme experiments de preconcentració amb dues geometries diferents: un sistema de membrana laminar (LSLM) on recircula la fase receptora i un sistema de fibra buida (HFSLM). Els millors resultats s'obtenen amb el mòdul de fibra buida, amb factors de concentració de 25 i 3 per a glifosat i AMPA, respectivament, fent recircular durant 24 hores 100 ml de solució de càrrega i 4 ml de solució receptora. També s'aplica una tècnica més selectiva, la cromatografia d'afinitat amb ió metàl·lic immobilitzat (IMAC), basada en la interacció entre els anàlits i un metall immobilitzat en una resina a través d'un grup funcional d'aquesta. En aquest estudi s'immobilitza pal·ladi al grup funcional 8-hidroxiquinoleïna de la resina amb matriu acrílica Spheron Oxine 1000 i s'avalua per a l'extracció i preconcentració de glifosat i AMPA. Per a ambdós anàlits l'adsorció és del 100 % i les recuperacions són superiors al 80 % i al 60 % per a glifosat i AMPA, respectivament, utilitzant HCl 0,1 M + NaCl 1 M com a eluent. Aquests resultats es comparen amb els obtinguts amb dues resines més, també carregades amb pal·ladi: Iontosorb Oxin 100, que té el mateix grup funcional però matriu de cel·lulosa, i Spheron Thiol 1000, on el grup funcional és un tiol i la matriu també és acrílica. Per al glifosat els resultats són similars amb totes les resines, però per a l'AMPA la resina Spheron Thiol és la única que proporciona recuperacions superiors al 93 %. Finalment, una altra opció estudiada és l'acoblament de dues columnes de cromatografia líquida (LC-LC). En l'estudi l'objectiu és millorar el mètode existent per a glifosat i AMPA en aigües naturals on el LOD era de 0,25 ug/l. El mètode consisteix en la derivatització precolumna amb el reactiu fluorescent FMOC i l'anàlisi amb l'acoblament LC-LC-fluorescència. Variant lleugerament les condicions de derivatització s'aconsegueix quantificar 0,1 ug/l de glifosat i AMPA. Es fortifiquen aigües naturals amb 0,1, 1 i 10 ug/l dels anàlits per validar el mètode. S'obtenen recuperacions d'entre el 85 % i el 100 %, amb desviacions estàndard relatives inferiors al 8 %. Aplicant una tècnica de preconcentració prèvia a la derivatització i anàlisi utilitzant una resina de bescanvi aniònic, Amberlite IRA-900, es millora la sensibilitat del mètode i s'assoleix un LOD per al glifosat de 0,02 ug/l.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0 Hz under a load from 0 to 250 N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two-photon polymerization is a powerful tool for fabricating three-dimensional micro/nano structures for applications ranging from nanophotonics to biology. To tailor such structure for specific purposes it is often important to dope them. In this paper we report on the fabrication of structures, with nanometric surface features (resolution of approximately 700 nm), using two-photon polymerization of an acrylic resin doped with the biocompatible polymer chitosan using a guest-host scheme. The fluorescence background in the Raman spectrum indicates the presence of chitosan throughout the structure. Mechanical characterization reveals that chitosan does not affect the mechanical properties of the host acrylic resin and, consequently, the structures exhibit excellent integrity. The approach presented in this work can be used in the fabrication of micro- and nanostructures containing biopolymers for biomedical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The corrosive phenomenon on reinforced concrete structures is one of the most founded pathologies on the coastal area. With the objective to prevent the process development, or even, retard its beginning, it was studied the application of inorganic covering over concrete surfaces, after its cure, as well as, evaluate the efficiency of the covering applied on the concrete in reducing its porosity of concrete preventing the entrance of aggressive agents to preserve the integrity of the existing armor inside it, comparing the result obtained with the body-of-proof reference, that didn´t receive covering protection. On the concrete production it was used Portland Cement CP II 32, coarse aggregate, fine aggregate and water from the local distributive. Two types of covering were used, one resin based of silicon and solvent and other white cement based, selected sands and acrylic resin. The concrete mixture adopted was 1:1,5:2,5 (cement, fine aggregate, coarse aggregate) and 0.50 water/cement ratio. With the concrete on fresh state was made the experiment test to determinate the workability. On the hardened state was made the concrete resistance experiment, absorption of water and electrochemical experiments, through polarization curves. Also was held optical microscopy and Scanning Electron Microscopy experiments to analyze the layer of the covering applied to the concrete surface and the interface between the concrete and the layer. The obtained results shows that the covering applied to the concrete surface didn´t affect the resistance towards compression. On the absorption of water occurred a diminution of the percentage absorbed, improving the concrete development by making it more impermeable towards the entrance of aggressive agents. The electrochemical experiment results confirmed the water absorption results; the body-of-proof covered presented larger protection towards the development of corrosives process and retarded the evolution of the corrosive phenomenon

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite Candida species are often human commensals isolated from various oral sites such as: tongue, cheek and palatal mucosa plus subgingival region, there are some properties linked to the organism commonly known as virulence factors which confer them the ability to produce disease. Oral candidiasis is one of the main oral manifestations reported in literature related to kidney transplant patients. The objectives of the present study were to identify and investigate virulence factors of yeasts isolated from the oral cavity of kidney transplant recipients admitted at the Hospital Universitário Onofre Lopes, in Natal RN. Seventy Candida species isolated from 111 kidney transplant recipients were investigated in this study. Identification of the isolates was performed by using the evidence of germ tube formation, hypertonic broth, tolerance to grow at 42°C, micromorphology and biochemical profiles. We observed a high rate of isolation of yeasts from the oral cavity of kidney transplant recipients (63.1%) being C. albicans was the most prevalent species. Oral candidiasis was diagnosed in 14.4% of transplant recipients. We evaluated virulence properties of the isolates regarding to: biofilm formation on polystyrene microplates as well as XTT reduction, adherence to acrylic resin and human buccal epithelial cells and proteinase activity. Most isolates were able to form biofilm by the method of adhesion to polystyrene. All isolates of Candida spp. remained viable during biofilm formation when analyzed by the method of XTT reduction. The number of CFU attached to the acrylic resin suggested high adherence for C. parapsilosis. C. albicans isolates showed higher median adherence to human buccal epithelial cells than non-C. albicans Candida isolates. Nevertheless, this difference was not statistically significant. C. dubliniensis showed low ability to adhere to plastic and epithelial cells and biofilm formation. Proteolytic activity was observed for all the isolates investigated, including the unique isolate of C. dubliniensis. There was a statistically significant association between proteinase production and the presence of oral candidiasis. Studies related to oral candidiasis in renal transplant recipients are limited to clinical and epidemiological data, but investigations concerning Candida spp. virulence factor for this group of individuals are still scarce. We emphasize the importance of studies related to virulence factors of yeasts isolated from this population to contribute to the knowledge of microbiological aspects of oral candidiasis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the plant species Copernicia prunifera (Miller) H. E. Moore (carnauba), naturally occurring which prevails in the northeast region of Brazil was the subject of studies aiming its use as external coating of pipelines used in petroleum industry. The part of the plant worked were the leaves, also called straw, which were coated with resinous material. For this purpose, it was necessary to evaluate the effectiveness of the use of acrylic resins in the straw carnauba coating. The properties of the untreated carnauba straw and chemically treated with sodium hydroxide, hexane and carbon tetrachloride were investigated by ATRFTIR, SEM and thermal analysis. The first two techniques showed that treatment with solvents has caused major changes in the straw surface, while the thermal analysis indicated that the sodium hydroxide caused variations in thermal stability of straw constituents. Water absorption measurements showed that treatments have accelerated the absorption process and the reduction of contact angle values for treated samples with solvents indicated higher hidrophilicity of straw. The tensile tests showed lower values of elastic modulus and tensile strength for treated samples. Furthermore, coatings using pure commercial resins A and B as well as the formulations with clay were applied in straw and they were examined once again through thermal analysis, water absorption measurements, contact angle and mechanical tests. To analyze the effect of heat ageing, samples were subjected to tensile tests again in order to assess its resistance. The results showed that the resins/clay formulations increased thermal stability of straw, they promoted a good impermeabilization and caused significant decrease in the values of elastic modulus and tensile strength. Evaluating the ageing effect on the mechanical properties, it has been showed good recovery to the coated straw with the formulations A 60 and A 80% in modulus and tensile strength values and elongation at break values have remained very close. It is thus concluded that the carnauba straw can be used as a coating of pipelines with significant cost savings, since there is no need for pretreatment for its use and shows itself as a viable biotechnology alternative, contributing to the quality of coatings material and environment preservation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a lack of clinical studies evaluating techniques of functional impression for partially edentulous arches. The aim of this double-blind non-randomized controlled clinical trial was to compare the efficacy of altered cast impression (ACI) and direct functional impression (DFI) techniques. The efficacy was evaluated regarding the number of occlusal units on denture teeth, mucosa integrity at 24-hour follow-up and denture base extension. The sample included 51 patients (female and male) with mean age of 58.96 years treated at Dental Department of UFRN. The patients, exhibiting edentulous maxilla and mandibular Kennedy class I, were divided into two groups (group ACI, n=29; group DFI, n=22). Clinical evaluation was based on the number of occlusal units on natural and/or artificial teeth, mucosa integrity at 24-hour follow-up, and denture base extension. Statistical analysis was conducted using the software SPSS 17.0® (SPSS Inc., Chicago, Illinois). Student T-test was used to reveal association between number of occlusal units and impression technique while chi-square test showed association between mucosa integrity and impression technique. Fischer s exact test was applied for association between denture base extension and impression technique at 95% level of significance. No significant difference was observed between the groups regarding number of occlusal units, mucosa integrity and denture base extension. The altered cast technique did not provide significant improvement in comparison to the direct technique when the number of occlusal units, mucosa integrity and denture base extension

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram eviscerados os globos oculares esquerdos de 32 ratos, linhagem Wistar, divididos em quatro grupos (A, B, C, D) constituídos, cada um, de cinco testemunhas e três controles. Nos animais-testemunha introduziu-se, dentro da capa córneo-escleral, uma esfera de resina acrílica (metilmetacrilato), previamente confeccionada e esterilizada por autoclavagem, ao passo que nos controles a cavidade eviscerada foi mantida sem prótese. Os ratos dos grupos A, B, C e D foram sacrificados respectivamente aos 7, 15, 30 e 90 dias de pós-operatório, quando os conteúdos orbitários esquerdos foram exenterados e preparados para o exame histopatológico. Observou-se que os animais-testemunha tiveram resposta inflamatória do tipo tecido de granulação ao redor da prótese de cavidade, com edema inflamatório da córnea especialmente nos grupos A e B, quando se iniciou a regressão da inflamação aguda. A cavidade orbitária manteve o tamanho em todos os grupos nos animais-testemunha e houve contração significativa nos animais-controle. Com estas observações, foi possível concluir que a esfera de resina acrílica é uma opção, de baixo custo e fácil confecção, para correção de defeito estético causado pela perda do globo ocular.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4), osteomielite (n=1), má-união (n=1), falência ou quebra de implante (n=4), sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.