986 resultados para visual processes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To compare septal and vascular matrix remodelling, vascular occlusion, Pulmonary function tests and survival between two groups: one with idiopathic non-specific interstitial pneumonia (NSIP) and one with NSIP associated with systemic sclerosis (SSc). Methods and results: Pulmonary biopsy specimens were examined from 40 patients, 22 with NSIP and 18 with NSIP associated with SSc. The content of septal collagen and elastic fibres, as well as the elastic fibres in the vascular interstitium, were higher in the SSc group (P = 0.01, P = 0.001 and P < 0.0001, respectively). Among pulmonary function tests. the diffusing capacity for carbon monoxide/alveolar volume was affected to a greater extent in the SSc group (59%) of the predicted value in SSc and 97% in the idiopathic group). There were no differences in collagen content of the vascular interstitium, arterial occlusion, or survival between the two groups. Conclusions: Although the fibrotic process is more intense in the SSc group. it, does not affect the prognosis of these patients. Because the elastotic process is higher in the SSc group, this might suggest that autoimmune inflammatory mechanisms affecting the elastic fibre system play a greater role in the pathogenesis and pulmonary remodelling process of SSc NSIP than in idiopathic NSIP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate rates of visual field progression in eyes with optic disc hemorrhages and the effect of intraocular pressure (IOP) reduction on these rates. Design: Observational cohort study. Participants: The study included 510 eyes of 348 patients with glaucoma who were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and followed for an average of 8.2 years. Methods: Eyes were followed annually with clinical examination, standard automated perimetry visual fields, and optic disc stereophotographs. The presence of optic disc hemorrhages was determined on the basis of masked evaluation of optic disc stereophotographs. Evaluation of rates of visual field change during follow-up was performed using the visual field index (VFI). Main Outcome Measures: The evaluation of the effect of optic disc hemorrhages on rates of visual field progression was performed using random coefficient models. Estimates of rates of change for individual eyes were obtained by best linear unbiased prediction (BLUP). Results: During follow-up, 97 (19%) of the eyes had at least 1 episode of disc hemorrhage. The overall rate of VFI change in eyes with hemorrhages was significantly faster than in eyes without hemorrhages (-0.88%/year vs. -0.38%/year, respectively, P < 0.001). The difference in rates of visual field loss pre- and post-hemorrhage was significantly related to the reduction of IOP in the post-hemorrhage period compared with the pre-hemorrhage period (r = -0.61; P < 0.001). Each 1 mmHg of IOP reduction was associated with a difference of 0.31%/year in the rate of VFI change. Conclusions: There was a beneficial effect of treatment in slowing rates of progressive visual field loss in eyes with optic disc hemorrhage. Further research should elucidate the reasons why some patients with hemorrhages respond well to IOP reduction and others seem to continue to progress despite a significant reduction in IOP levels. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 2061-2066 (C) 2010 by the American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate clinical and MRI findings that are predictive of both visual loss in patients with pituitary adenomas and visual recovery after treatment. Design: Cohort study. Participants: Thirty patients (60 eyes) with pituitary adenoma. Methods: Patients underwent neuro-ophthalmic examination and MRI before and after optic chiasm decompression. Visual field (VF) was assessed using the mean deviation in standard automated perimetry (SAP) and temporal mean defect, the average of 22 temporal values of the total deviation plot. Tumour size was measured on sagittal and coronal cuts. Results: Visual loss was found in 47 eyes; 35 had optic atrophy (subtle in 9, moderate in 14, and severe in 12). Before treatment, the average SAP mean deviation and temporal mean defect were -11.78 (SD 8.56) dB and -18.66 (SD 11.20) dB, respectively. The chiasm was 17.3 (SD 6.2, range 10-34) mm above the reference line on the sagittal and 21.8 (SD 8.3, range 12-39) mm on the coronal images. Tumour size correlated with the severity of VF defect. VF improvement occurred in 80% of eyes after treatment. The degree of optic atrophy, visual loss, and tumour size were significantly associated with improvement after treatment. Conclusions: The best predictive factor for visual loss was tumour size, and factors related to visual recovery were the degree of optic atrophy, the severity of VF defect, and the tumour size. Diagnosing pituitary adenomas before optic atrophy becomes severe may be related to a better prognosis in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.