992 resultados para variable sampling interval


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An equivalent unit cell waveguide approach (WGA) is described to study the behavior of a multilayer reflect array of variable-size patches/dipoles, The approach considers normal incidence of a plane wave on an infinite periodic array of identical radiating elements and introduces an equivalent unit cell waveguide to obtain the reflection coefficient. A field matching technique and method of moments (MoM) is used to determine fields in different layers of the equivalent waveguide. Good agreements for the phase of the reflection coefficient between the proposed model and those published in selected literatures are obtained. (C) 2002 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A balanced sampling plan excluding contiguous units (or BSEC for short) was first introduced by Hedayat, Rao and Stufken in 1988. These designs can be used for survey sampling when the units are arranged in one-dimensional ordering and the contiguous units in this ordering provide similar information. In this paper, we generalize the concept of a BSEC to the two-dimensional situation and give constructions of two-dimensional BSECs with block size 3. The existence problem is completely solved in the case where lambda = 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C,C-Dicyanoketenimines 10a-c were generated by flash vacuum thermolysis of ketene NS-acetals 9a-c or by thermal or photochemical decomposition of alpha-azido-,beta-cyanocinnamonitrile 11. In the latter reaction, 3,3-dicyano-2-phenyl-1-azirine 12 is also formed. IR spectroscopy of the keteniminines isolated in Ar matrixes or as neat films, NMR spectroscopy of 10c, and theoretical calculations (B3LYP/6-31G*) demonstrate that these ketenimines have variable geometry, being essentially linear along the CCN-R framework in polar media (neat films and solution), but in the gas phase or Ar matrix they are bent, as is usual for ketenimines. Experiments and calculations agree that a single CN substituent as in 13 is not enough to enforce linearity, and sulfonyl groups are less effective that cyano groups in causing linearity. C,C-Bis(methylsulfonyl)ketenimines 4-5 and a C-cyano-C-(methylsulfonyl)ketenimine 15 are not linear. The compound p-O2NC6H4N=C= C(COOMe)2 previously reported in the literature is probably somewhat linearized along the CCNR moiety. A computational survey (B3LYP/6-31G*) of the inversion barrier at nitrogen indicates that electronegative C-substituents dramatically lower the barrier; this is also true of N-acyl substituents. Increasing polarity causes lower barriers. Although N-alkylbis(methylsulfonyl)ketenimines are not calculated to be linear, the barriers are so low that crystal lattice forces can induce planarity in N-methylbis(methylsulfonyl)ketenimine 3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The risk of cardiac events in patients undergoing major noncardiac surgery is dependent on their clinical characteristics and the results of stress testing. The purpose of this study was to develop a composite approach to defining levels of risk and to examine whether different approaches to prophylaxis influenced this prediction of outcome. One hundred forty-five consecutive patients (aged 68 +/- 9 years, 79 men) with >1 clinical risk variable were studied with standard dobutamine-atropine stress echo before major noncardiac surgery. Risk levels were stratified according to the presence of ischemia (new or worsening wall motion abnormality), ischemic threshold (heart rate at development of ischemia), and number of clinical risk variables. Patients were followed for perioperative events (during hospital admission) and death or infarction over the subsequent 16 10 months. Ten perioperative events occurred in 105 patients who proceeded to surgery (10%, 95% confidence interval [CI] 5% to 17%), 40 being cancelled because of cardiac or other risk. No ischemia was identified in 56 patients, 1 of whom (1.8%) had a perioperative infarction. Of the 49 patients with ischemia, 22 (45%) had 1 or 2 clinical risk factors; 2 (9%, 95% CI 1% to 29%) had events. Another 15 patients had a high ischemic threshold and 3 or 4 risk factors; 3 (20%, 95% Cl 4% to 48%) had events. Twelve patients had a low ischemic threshold and 3 or 4 risk factors; 4 (33%, 95% CI 10% to 65%) had events. Preoperative myocardial revascularization was performed in only 3 patients, none of whom had events. Perioperative and long-term events occurred despite the use of beta blockers; 7 of 41 eta blocker-treated patients had a perioperative event (17%, 95% CI 7% to 32%); these treated patients were at higher anticipated risk than untreated patients (20 +/- 24% vs 10 +/- 19%, p = 0.02). The total event rate over late follow-up was 13%, and was predicted by dobutamine-atropine stress echo results and heart rate response. (C) 2002 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A repetitive DNA motif was used as a marker to identify novel genes in the mucosal pathogen Moraxella catarrhalis. There is a high prevalence of such repetitive motifs in virulence genes that display phase variable expression. Two repeat containing loci were identified using a digoxigenin-labelled 5'-(CAAC)(6)-3' oligonucleotide probe. The repeats are located in the methylase components of two distinct type III restriction-modification (R-M) systems. We suggest that the phase variable nature of these R-M systems indicates that they have an important role in the biology of M. catarrhalis. (C) 2002 Published by Elsevier Science B.V. on behalf of the Federation of European Microbiological Societies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the effect of periparturient disease accompanied by vulval discharge, and weaning-to-mating intervals, on sow fertility and litter size. Design Reproductive data were collected and analysed from 19 Hungarian swine herds over a 4 year period. Conception rates, farrowing rates and litter sizes of sows with periparturient disease accompanied by vulval discharge were used to evaluate the relationship between duration of vulval discharge and subsequent fertility and litter size. The possibility of interactions between weaning-to-mating intervals and duration of vulval discharges was investigated to determine if there was any effect on subsequent fertility and litter size. Results and conclusions Both parity 1 and parity 2 to 8 sows having had periparturient disease accompanied by vulval discharge in excess of 6 days duration had significantly (P < 0.001) lower subsequent fertility (conception, farrowing and adjusted farrowing rates) compared with sows of similar parity where the duration of vulval discharge was < 4 or 4 to 6 days. There was no difference in fertility rates between sows, in both parity categories, with vulval discharge for < 4 days compared with 4 to 6 days. A duration of vulval discharge in excess of 6 days in parity 1 sows significantly reduced litter size (total born and live-born) in subsequent farrowings, but not in parity 2 to 8 sows. There was no interaction between the duration of vulval discharge and post-weaning to mating intervals. However sows with weaning to mating intervals between 7 and 10 days had smaller (P < 0.001) subsequent litter sizes compared with 3 to 6 or 11 to 14 day intervals. It was concluded that the duration of vulval discharge in excess of 6 days was an indication of a severe persistent endometritis adversely affecting fertility of sows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to examine the influence of three different high-intensity interval training (HIT) regimens on endurance performance in highly trained endurance athletes. Methods: Before, and after 2 and 4 wk of training, 38 cyclists and triathletes (mean +/- SD; age = 25 +/- 6 yr; mass = 75 +/- 7 kg; (V)over dot O-2peak = 64.5 +/- 5.2 mL.kg(-1).min(-1)) performed: 1) a progressive cycle test to measure peak oxygen consumption ((V)over dotO(2peak)) and peak aerobic power output (PPO), 2) a time to exhaustion test (T-max) at their (V)over dotO(2peak) power output (P-max), as well as 3) a 40-kin time-trial (TT40). Subjects were matched and assigned to one of four training groups (G(1), N = 8, 8 X 60% T-max P-max, 1:2 work:recovery ratio; G(2), N = 9, 8 X 60% T-max at P-max, recovery at 65% HRmax; G(3), N = 10, 12 X 30 s at 175% PPO, 4.5-min recovery; G(CON), N = 11). In addition to G(1) G(2), and G(3) performing HIT twice per week, all athletes maintained their regular low-intensity training throughout the experimental period. Results: All HIT groups improved TT40 performance (+4.4 to +5.8%) and PPO (+3.0 to +6.2%) significantly more than G(CON) (-0.9 to + 1.1 %; P < 0.05). Furthermore, G(1) (+5.4%) and G(2) (+8.1%) improved their (V)over dot O-2peak significantly more than G(CON) (+ 1.0%; P < 0.05). Conclusion: The present study has shown that when HIT incorporates P-max as the interval intensity and 60% of T-max as the interval duration, already highly trained cyclists can significantly improve their 40-km time trial performance. Moreover, the present data confirm prior research, in that repeated supramaximal HIT can significantly improve 40-km time trial performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stochastic differential equations (SDEs) arise from physical systems where the parameters describing the system can only be estimated or are subject to noise. Much work has been done recently on developing higher order Runge-Kutta methods for solving SDEs numerically. Fixed stepsize implementations of numerical methods have limitations when, for example, the SDE being solved is stiff as this forces the stepsize to be very small. This paper presents a completely general variable stepsize implementation of an embedded Runge Kutta pair for solving SDEs numerically; in this implementation, there is no restriction on the value used for the stepsize, and it is demonstrated that the integration remains on the correct Brownian path.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The region surrounding mecA in methicillin-resistant Staphylococcus aureus (MRSA) is highly variable. We describe an approach for the rapid genotyping of MRSA by assaying for the presence or absence of variable or mobile elements previously shown to be associated with the mecA region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An equivalent unit cell waveguide approach (WGA) to designing 4 multilayer microstrip reflectarray of variable size patches is presented. In this approach, a normal incidence of a plane wave on an infinite periodic array of radiating elements is considered to obtain reflection coefficient phase curves for the reflectarray's elements. It is shown that this problem is equivalent to the problem of reflection of the dominant TEM mode in a waveguide with patches interleaved by layers of dielectric. This waveguide problem is solved using a field matching technique and a method of moments (MoM). Based on this solution, a fast computer algorithm is developed to generate reflection coefficient phase curves for a multilayer microstrip patch reflectarray. The validity of the developed algorithm is tested against alternative approaches and Agilent High Frequency Structure Simulator (HFSS). Having confirmed the validity of the WGA approach, a small offset feed two-layer microstrip patch array is designed and developed. This reflectarray is tested experimentally and shows good performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The surgical cure rate for primary hyperparathyroidism is greater than 95%. For those who have recurrent or persistent disease, preoperative localization improves reoperation success rates. Selective parathyroid venous sampling (SPVS) for intact parathyroid hormone is particularly useful when non-invasive localization techniques are negative or inconclusive. Methods: We present all known cases (n = 13) between 1994 and 2002 who had venous sampling for localization at our institution prior to reoperation for recurrent or persistent primary hyperparathyroidism. Comparison was made with non-invasive localization procedures. Results of invasive and non-invasive localization were correlated with surgical findings. Results: Of the nine reoperated cases, eight had positive correlations between SPVS and operative findings and histopathology. SPVS did not reveal the parathyroid hormone source in one case with negative non-invasive localization procedures. Comparisons between SPVS, computerized tomography (CT), and parathyroid scintigraphy (MIBI) as expressed in terms of true positive (TP), false positive (FP) and false negative (FN) were: SPVS - TP 88.8%, FP 0%, FN 11.1%; CT - TP 22.2%, FP 22.2%, FN 55.5%; and MIBI - TP 33.3%, FP 0%, FN 66.6%. At least seven of the nine operated cases have been cured; another remained normocalcaemic 2 weeks after subtotal parathyroidectomy. Conclusion: In our institution SPVS has proven to be a valuable tool in cases with recurrent or persistent primary hyperparathyroidism and negative non-invasive localization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Timed Interval Calculus, a timed-trace formalism based on set theory, is introduced. It is extended with an induction law and a unit for concatenation, which facilitates the proof of properties over trace histories. The effectiveness of the extended Timed Interval Calculus is demonstrated via a benchmark case study, the mine pump. Specifically, a safety property relating to the operation of a mine shaft is proved, based on an implementation of the mine pump and assumptions about the environment of the mine. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate nonclassical Stokes-operator variances in continuous-wave polarization-squeezed laser light generated from one and two optical parametric amplifiers. A general expression of how Stokes-operator variances decompose into two-mode quadrature operator variances is given. Stokes parameter variance spectra for four different polarization-squeezed states have been measured and compared with a coherent state. Our measurement results are visualized by three-dimensional Stokes-operator noise volumes mapped on the quantum Poincare sphere. We quantitatively compare the channel capacity of the different continuous-variable polarization states for communication protocols. It is shown that squeezed polarization states provide 33% higher channel capacities than the optimum coherent beam protocol.