968 resultados para ultrasound ct


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Ultrasound scan in the mid-trimester of pregnancy is now a routine part of prenatal care in most European countries. The objective of this study was to evaluate the prenatal diagnosis of dysmorphic syndromes by fetal ultrasound examination. METHODS: Data from 20 registries of congenital malformations in 12 European countries were included in the study. RESULTS: There were 2454 cases with congenital heart diseases, 479 of which were recognized syndromes, including 375 chromosomal anomalies and 104 syndromes without chromosomal anomalies. Fifty-one of the 104 were detected prenatally (49.0%). One hundred and ninety-two of 1130 cases with renal anomalies were recognized syndromes, including 128 chromosomal anomalies and 64 syndromes without chromosomal anomalies; 162 of them (84.4%) were diagnosed prenatally, including 109 chromosomal anomalies and 53 non-chromosomal syndromes. Fifty-four of the 250 cases with limb defects were recognized syndromes, including 16 chromosomal syndromes and 38 syndromes without chromosomal anomalies; 21 of these 54 syndromes were diagnosed prenatally (38.9%), including 9 chromosomal syndromes. There were 243 cases of abdominal wall defects including 57 recognizable syndromes, 48 with omphalocele and 9 with gastroschisis; 48 were diagnosed prenatally (84.2%). Twenty-six of the 187 cases with diaphragmatic hernia had recognized syndromes, including 20 chromosomal aberrations and 6 syndromes without chromosomal anomalies. Twenty-two of them (84.6%) were detected prenatally. Sixty-four of 349 cases with intestinal anomalies were recognized syndromes; 24 were diagnosed prenatally (37.5%). There were 553 cases of cleft lip and palate (CL(P)) and 198 of cleft palate (CP) including 74 chromosomal anomalies and 73 recognized non-chromosomal syndromes. Prenatal diagnosis was made in 51 cases of CL(P) (53.7%) and 7 of CP (13.7%). Twenty-two of 188 anencephalic cases were syndromic and all were diagnosed prenatally. Of 290 cases with spina bifida, 18 were recognized syndromes, and of them 17 were diagnosed prenatally. All 11 syndromic encephaloceles were diagnosed prenatally. CONCLUSIONS: Around 50% of the recognized syndromes which are associated with major congenital anomalies (cardiac, renal, intestinal, limb defects, abdominal wall defects and oral clefts) can be detected prenatally by the anomaly scan. However the detection rate varies with the type of syndrome and with the different countries' policies of prenatal screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the influence of shorter- and longer-acting intra-articular anaesthetics on post-arthrographic pain. MATERIALS AND METHODS: 154 consecutive patients investigated by MR or CT arthrographies were randomly assigned to one of the following groups: 1--intra-articular contrast injection only; 2--lidocain 1% adjunction; or 3--bupivacain 0.25% adjunction. Pain was assessed before injection, at 15 min, 4 h, 1 day and 1 week after injection by visual analogue scale (VAS). RESULTS: At 15 min, early mean pain score increased by 0.96, 0.24 and 0 in groups 1, 2 and 3, respectively. Differences between groups 1 & 3 and 1 & 2 were statistically significant (p=0.003 and 0.03, respectively), but not between groups 2 & 3 (p=0.54). Delayed mean pain score increase was maximal at 4 h, reaching 1.60, 1.22 and 0.29 in groups 1, 2 and 3, respectively. Differences between groups 1 & 2 and 2 & 3 were statistically significant (p=0.002 and 0.02, respectively), but not between groups 1 & 2 (p=0.46). At 24 h and 1 week, the interaction of local anaesthetics with increase in pain score was no longer significant. Results were independent of age, gender and baseline VAS. CONCLUSION: Intra-articular anaesthesia may significantly reduce post-arthrographic pain. Bupivacain seems to be more effective than lidocain to reduce both early and delayed pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical potential of diffusion-weighted MR imaging with apparent diffusion coefficient (ADC) mapping for the assessment of gastrointestinal stromal tumor (GIST) response to targeted therapy in comparison with 18F-FDG PET/CT. Methods and materials: Five patients (3W/2M, aged 56 ± 13 y) with metastatic GIST underwent both a 18F-FDG PET/CT (Discovery LS, GE Healthcare) and a MRI (VIBE T1 Gd, DWI [b = 50,300,600] and ADC mapping) before and after change in therapy. Exams were first analyzed blindly, then PET/CT images were coregistered to T1 Gd MR images for lesion detection. SUVmax and ADC were measured for the six largest lesions on MRI. The relationship between SUVmax and ADC was analyzed using Spearman's correlation. Results: Altogether, 24 lesions (15 hepatic and 9 non-hepatic) were analyzed on both modalities. Three PET/CT lesions (12.5%) were initially not considered on ADC and 4 lesions on the second PET/CT were excluded because of hepatic vascular activity spillover. SUVmax decreased from 7.2 ± 7.7 g/mL to 5.9 ± 5.9 g/mL (P = 0.53) and ADC increased from 1.2x10-3 mm2/s ± 0.4 to 1.4x10-3 mm2/s ± 0.4 (P = 0.07). There was a significant association between SUVmax decrease and ADC increase (rho= -0.64, P = 0.004). Conclusion: Changes in ADC from diffusion-weighted MRI reflect response of 18F-FDG-avid GIST to therapy. The exact diagnostic value of DWI needs to be investigated further, as well as the effect of lesion size and time under therapy before imaging. Furthermore, the proven association between SUVmax and ADC may be useful for the assessment of treatment response in 18F-FDG non-avid GIST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The written report (or its electronic counterpart) is the primary mode of communication between the physician interpreting an imaging study and the referring physician. The content of this report not only influences patient management and clinical outcomes but also serves as legal documentation of services provided and can be used to justify medical necessity, billing accuracy, and regulatory compliance. Generating a high-quality PET/CT report is perhaps more challenging than generating a report for other imaging studies because of the complexity of this hybrid imaging modality. This article discusses the essential elements of a concise and complete oncologic (18)F-FDG PET/CT report and illustrates these elements through examples taken from routine clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe osseous, chondral and tendinous lesions associated with fissures of the posterior labrum. To better understand the pathological processes leading to fissure of the posterior labrum. Materials and methods. Retrospective study of 43 CT arthrograms performed in 43 patients that showed a fissure of the posterior labrum. The following associated lesions were noted: osseous and chondral remodeling of the humeral head and/or glenoid and articular surface fissures of the rotator cuff. Based on type of associated lesions, patients were separated into one of four pathological subgroups: posterior instability, posterosuperior or internal impingement, anterior instability and isolated fissure of the posterior labrum. RESULTS: Sixteen patients (37.2%) of patients showed posterior instability, 12 (27.9%) showed lesions of internal impingement, and 11 (25.6%) showed lesions of anterior instability. Only 4 patients (9.3%) had an isolated fissure of the posterior labrum. CONCLUSION: Posterior instability, internal impingement and anterior instability are the main pathologies leading to fissure of the posterior labrum, which seldom occurs in isolation. Evaluation of these associated lesions allows understanding of the underlying pathological processes leading to fissure of the posterior labrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We evaluated the potential for hybrid PET/MRI devices to provide integrated metabolic, functional and anatomic characterisation of patients with suspected coronary artery disease.Methods and Materials: Ten patients (5 with suspected hibernating myocardium and 5 healthy volunteers) performed an imaging study using a hybrid PET/MRI (Philips). Viability assessed by 18F-FDG was performed in diseased patients along with MRI anatomic and functional study and reassessed within 30 minutes by conventional PET/CT. Non-contrast right coronary artery (RCA) targeted and whole heart 3D coronary angio-MRI using ECG-gating and respiratory navigator was performed in healthy volunteers with reconstruction performed using MPR and volume rendering. The extent of metabolic defect (MD) using PET/MRI and PET/CT was compared in patients and coronary territories (LAD, CX, RCA). Assessability of coronary lumen was judged as good, sub-optimal or non-assessable using a 16-segments coronary model.Results: Metabolic assessment was successful in all patients with MD being 19.2% vs 18.3% using PET/MRI and PET/CT, respectively (P=ns). The MD was 10.2%, 6 %, and 3 % vs 9.3%, 6 % and 3 % for LAD, CX and RCA territories, respectively (P= ns). Coronary angio-MRI was successful in all volunteers with 66 coronary segments visualised overall. The RCA was fully visualised in 4/5 volunteers and the left coronary arteries in 4/5 volunteers. Assessability in visualised segments was good, sub-optimal and non-assessable in 88 %, 2 % and 10 %, respectively.Conclusion: Hybrid PET/MRI devices may enable metabolic evaluation comparable to PET/CT with additional value owing to accurate functional and anatomical information including coronary assessment.