952 resultados para spiral bevel gear


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growth history of two populations of snowball garnet from the Lukmanier Pass area (central Swiss Alps) was examined through a detailed analysis of three-dimensional geometry, chemical zoning and crystallographic orientation. The first population, collected in the hinge of a chevron-type fold, shows an apparent rotation of 360 degrees. The first 270 degrees are characterized by spiral-shaped inclusion trails, gradual and concentric Mn zoning and a single crystallographic orientation, whereas in the last 90 degrees, crenulated inclusion trails and secondary Mn maxima centred on distinct crystallographic garnet domains are observed. Microstructural, geochemical and textural data indicate a radical change in growth regime between the two growth sequences. In the first 270 degrees, growth occurred under rotational non-coaxial flow, whereas in the last 90 degrees, garnet grew under a non-rotational shortening regime. The second population, collected in the limb of the same chevron-type fold structure, is characterized by a spiral geometry that does not exceed 270 degrees of apparent rotation. These garnet microstructures do not record any evidence for a modification of the stress field during garnet growth. Concentric Mn zoning as well as a single crystallographic orientation are observed for the entire spiral. Electron backscatter diffraction data indicate that nearly all central domains in the snowball garnet are characterized by one [001] axis oriented (sub-)parallel to the symmetry axis and by another [001] axis oriented (sub-)parallel to the orientation of the internal foliation. These features suggest that the crystallographic orientation across the garnet spiral is not random and that a relation exists among the symmetry axis, the internal foliation and the crystallographic orientation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Ultrasounds are a useful tool when looking for indirect evidence in favor of pulmonary embolism. The aim of this study was to determine the incidence of acute cor pulmonale and deep venous thrombosis revealed by ultrasonographic techniques in a population of patients presenting with pulmonary embolism. METHODS: 96 consecutive patients with a mean (+/- SD) age of 65 +/- 15 years, admitted to our hospital for pulmonary embolism were included in this study. The diagnosis of pulmonary embolism was made either by spiral computed tomography or selective pulmonary angiography. Each patient subsequently underwent both trans-thoracic echocardiography and venous ultrasonography. The diagnostic criterion used for defining acute cor pulmonale by echocardiography was the right to left ventricular end-diastolic area ratio over (or equal to) 0.6. Diagnosis of deep venous thrombosis was supported by the visualization of thrombi or vein incompressibility and/or the absence of venous flow or loss of flow variability by venous ultrasonography. RESULTS: Using ultrasounds, an acute cor pulmonale was found in 63% of our patients while 79% were found to have deep venous thrombosis and 92% of the patients had either acute cor pulmonale or deep venous thrombosis or both. All of the patients with proximal pulmonary embolism had acute cor pulmonale and/or deep venous thrombosis. The presence of acute cor pulmonale on echocardiography was significantly higher in patients with proximal pulmonary embolism (p < 0.0001). CONCLUSION: This study emphasizes the potential value of ultrasonographic techniques in the diagnosis of acute pulmonary embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To analyze outcomes after right portal vein embolization extended to segment IV (right PVE + IV) before extended right hepatectomy, including liver hypertrophy, resection rates, and complications after embolization and resection, and to assess differences in outcomes with two different particulate embolic agents. MATERIALS AND METHODS: Between 1998 and 2004, transhepatic ipsilateral right PVE + IV with particles and coils was performed in 44 patients with malignant hepatobiliary disease, including metastases (n = 24), biliary cancer (n = 14), and hepatocellular carcinoma (n = 6). Right PVE + IV was considered if the future liver remnant (FLR; segments II/III with or without I) was less than 25% of the total estimated liver volume (TELV). Tris-acryl microspheres (100-700 microm; n = 21) or polyvinyl alcohol (PVA) particles (355-1,000 microm; n = 23) were administered in a stepwise fashion. Smaller particles were used to occlude distal branches, followed by larger particles to occlude proximal branches until near-complete stasis. Coils were then placed in secondary portal branches. Computed tomographic volumetry was performed before and 3-4 weeks after right PVE + IV to assess FLR hypertrophy. Liver volumes and postembolization and postoperative outcomes were measured. RESULTS: After right PVE + IV with PVA particles, FLR volume increased 45.5% +/- 40.9% and FLR/TELV ratio increased 6.9% +/- 5.6%. After right PVE + IV with tris-acryl microspheres, FLR volume increased 69.0% +/- 30.7% and FLR/TELV ratio increased 9.7% +/- 3.3%. Differences in FLR volume (P = .0011), FLR/TELV ratio (P = .027), and resection rates (P = .02) were statistically significant. Seventy-one percent of patients underwent extended right hepatectomy (86% after receiving tris-acryl microspheres, 57% after receiving PVA). Thirteen patients (29%) did not undergo resection (extrahepatic spread [n = 9], inadequate hypertrophy [n = 3], other reasons [n = 1]). No patient developed postembolization syndrome or progressive liver insufficiency after embolization or resection. One death after resection occurred as a result of sepsis and hemorrhage. Median hospital stays were 1 day after right PVE + IV and 7 days after resection. CONCLUSION: Transhepatic ipsilateral right PVE + IV with use of particles and coils is a safe, effective method for inducing contralateral hypertrophy before extended right hepatectomy. Embolization with small spherical particles provides improved hypertrophy and resection rates compared with larger, nonspherical particles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the case of a young man with compression of both renal arteries by the crura of the diaphragm. Correct diagnosis of renal artery entrapment is difficult but crucial. The investigations rely on an high index of suspicion and include Doppler ultrasound and spiral computed tomography angiography, which permits visualization of the diaphragm and its relationships with the aorta. This pathology, unlike common renal artery stenoses, requires surgical decompression and sometimes aortorenal bypass graft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los problemas críticos de la pesquería de arrastre de menor escala, son las capturas de ejemplares juveniles, alta presencia de descartes, pesca incidental o accesoria y conflictos con los pescadores artesanales que usan redes de enmalle cortineras. En toda la zona de estudio, los índices de captura por unidad de esfuerzo (CPUE) fue 142,4 kg/h y 477,5 kg/lance, bycatch por unidad de esfuerzo (BPUE) fue 27,2 kg/h y 91,1 kg/lance. Los mayores CPUE fueron en la zona sur dentro de las 5 mn con 199,0 kg/h y 617,8 kg/lance. La composición de la captura relativa al peso estuvo dominada por el falso volador (Prionotus stephanophrys, 24,6%) y carajito (Diplectrum conceptione, 21,4%). Las especies incidentales más importantes fueron espejo (Selene peruviana, 9,8%), bereche (Larimus pacificus, 9,3%), cachema (Cynoscion analis, 4,0%), chiri (Peprilus medius, 2,9%), lenguado de boca chica (Etropus ectenes, 2,5%), doncella (Hemanthias peruanus, 2,1%). El descarte fue 19,1% de la captura, los principales recursos fueron merluza (Merluccius gayi peruanus, 39,1%), lengüeta (Symphurus sechurae, 10,9%), morena (Muraena clepsidra, 4,9%), pez hojita (Chloroscombrus orqueta, 4,8%), otras especies 31,5% (incluyendo restos de peces y equinodermos). El índice de impacto al ecosistema marino fue de 3,7 (1: no favorable al 10: favorable). Por lo que es un arte de pesca no amigable con el ecosistema marino que no debe usarse dentro del área costera

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La “red de encierre activada por buzos” o “bolichito de fondo” es un arte de pesca que por sus características técnicas y de operación es clasificado como no determinado y no reglamentado. Se realizó una evaluación técnica de este arte de pesca, que indica que su cobertura espacial está limitada a la capacidad de buceo, restringida a zonas muy someras, presenta baja respuesta de selectividad y alto poder de pesca al compararla con otras artes de pesca artesanales utilizadas en la misma área costera; tiene elevada extracción de juveniles y de fauna acompañante los que generalmente están en mayores porcentajes de estadios inmaduros (II) y maduración inicial (III). Se recomienda prohibir su uso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Challenging environmental conditions, including heat and humidity, cold, and altitude, pose particular risks to the health of Olympic and other high-level athletes. As a further commitment to athlete safety, the International Olympic Committee (IOC) Medical Commission convened a panel of experts to review the scientific evidence base, reach consensus, and underscore practical safety guidelines and new research priorities regarding the unique environmental challenges Olympic and other international-level athletes face. For non-aquatic events, external thermal load is dependent on ambient temperature, humidity, wind speed and solar radiation, while clothing and protective gear can measurably increase thermal strain and prompt premature fatigue. In swimmers, body heat loss is the direct result of convection at a rate that is proportional to the effective water velocity around the swimmer and the temperature difference between the skin and the water. Other cold exposure and conditions, such as during Alpine skiing, biathlon and other sliding sports, facilitate body heat transfer to the environment, potentially leading to hypothermia and/or frostbite; although metabolic heat production during these activities usually increases well above the rate of body heat loss, and protective clothing and limited exposure time in certain events reduces these clinical risks as well. Most athletic events are held at altitudes that pose little to no health risks; and training exposures are typically brief and well-tolerated. While these and other environment-related threats to performance and safety can be lessened or averted by implementing a variety of individual and event preventative measures, more research and evidence-based guidelines and recommendations are needed. In the mean time, the IOC Medical Commission and International Sport Federations have implemented new guidelines and taken additional steps to mitigate risk even further.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.