867 resultados para skull fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to identify the occurrence, type, location, and severity of dental injuries (DIs), as well as predictors for DIs, in pediatric patients with facial fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hyponatremia is a complication of diuretic treatment and has been recently identified as a novel factor associated with osteoporosis and fractures. The impact of diuretic-associated electrolyte disorders on osteoporotic fractures (OF) has rarely been studied systematically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone scintigraphy is a very sensitive diagnostic tool to detect elevated bone metabolism. In cases of fractures and fissure fractures, the radiopharmaceutical uptake in the bone is said to be increased within a few hours after the injury. In this retrospective study, the scintigraphic uptake characteristics at the fracture site of 36 horses with radiographically confirmed fractures or fissure fractures were evaluated. Uptake ratios between the fracture region and adjacent normal bone or soft tissue activity respectively were calculated and compared to different anamnestic and radiographic data. The overall sensitivity of bone scintigraphy was 94.4% (34 positive cases out of 36). In the 36 horses, no correlation between the age of the fracture and the radiopharmaceutical uptake was found. However, there seems to be a lack of sensitivity in early detection of equine pelvic fractures when a standing bone scintigraphy examination protocol is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cement augmentation using PMMA cement is known as an efficient treatment for osteoporotic vertebral compression fractures with a rapid release of pain in most patients and prevention of an ongoing kyphotic deformity of the vertebrae treated. However, after a vertebroplasty there is no chance to restore vertebral height. Using the technique of kyphoplasty a certain restoration of vertebral body height can be achieved. But there is a limitation of recovery due to loss of correction when deflating the kyphoplastic ballon and before injecting the cement. In addition, the instruments used are quite expensive. Lordoplasty is another technique to restore kyphosis by indirect fracture reduction as it is used with an internal fixateur. The fractured and the adjacent vertebrae are instrumented with bone cannulas bipediculary and the adjacent vertebrae are augmentated with cement. After curing of the cement the fractured vertebra is reduced by applying a lordotic moment via the cannulas. While maintaining the pretension the fractured vertebra is reinforced. We performed a prospective trial of 26 patients with a lordoplastic procedure. There was a pain relief of about 87% and a significant decrease in VAS value from 7.3 to 1.9. Due to lordoplasty there was a significant and permanent correction in vertebral and segmental kyphotic angle about 15.2 degrees and 10.0 degrees , respectively and also a significant restoration in anterior and mid vertebral height. Lordoplasty is a minimal invasive technique to restore vertebral body height. An immediate relief of pain is achieved in most patients. The procedure is safe and cost effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of the present study was to evaluate migration rates of cementless primary hemiarthroplasty in acute femoral neck fractures. In a longitudinal, prospective study 46 patients were treated by cementless hemiarthroplasty. Clinical follow up was correlated with the EBRA-FCA method. In 30% of all patients stem migration amounted to more than 2 mm; further, these patients were seen to have a high level of activity. A high degree of migration in more than 30% of all patients requires critical scepticism toward further use of the investigated cementless stem as hemiarthroplasty. According to literature, migration of more than 2 mm suggests a high probability of early aseptic loosening. In patients with a low degree of activity good results could be observed; nevertheless, in patients with a high level of activity the combination of the investigated cementless stem with a solid fracture head cannot be recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A systematic review was performed to find evidence for prophylactic administration of antibiotics in relation to treatment of maxillofacial fractures. METHODS: Four studies were retrieved that fulfilled most of the requirements of being randomized controlled clinical trials. RESULTS: An analysis of these studies showed a 3-fold decrease in the infection rate of mandibular fractures in the antibiotic treated groups compared with the control groups. A variety of antibiotics had been used with an apparently uniform effect. A "1-shot" regimen or a 1-day treatment course had a similar or perhaps even better effect than 7 days of treatment. No infections were related to condylar, maxillary, or zygoma fractures. CONCLUSION: A 1-shot or 1-day administration of prophylactic antibiotics seem to be the best documented to reduce infections in the management of mandibular fractures not involving the condylar region.