885 resultados para sales measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The particle orientation in several Y-Fe2O3magnetic tapes has been quantitatively evaluated by using the data of both Mössbauer and hysteresis loop measurements performed in the three orthogonal directions. A texture function has been obtained as a development of real harmonics. The profile of the texture function gives the quality of the different magnetic tapes. A different degree of particle orientation at the surface of the tape is evidenced by means of conversion electron Mössbauer spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IRA and the NPL have submitted ampoules of 166Hom to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures, thus becoming the third and fourth participants since 1989. The five samples of known activity of 166Hom now recorded in the SIR have activities between about 70 kBq and 500 kBq. The new results have enabled a re-evaluation of the key comparison reference value, and the degrees of equivalence between each equivalent activity measured in the SIR and the key comparison reference value (KCRV) have been calculated. The results are given in the form of a matrix for these four NMIs together with the recalculated degrees of equivalence of an APMP regional comparison held in 2000, comparison identifier APMP.RI(II)-K2.Ho-166m for six other NMIs. A graphical presentation is also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Acetate brain metabolism has the particularity to occur specifically in glial cells. Labeling studies, using acetate labeled either with 13C (NMR) or 11C (PET), are governed by the same biochemical reactions and thus follow the same mathematical principles. In this study, the objective was to adapt an NMR acetate brain metabolism model to analyse [1-11C]acetate infusion in rats. Methods: Brain acetate infusion experiments were modeled using a two-compartment model approach used in NMR.1-3 The [1-11C]acetate labeling study was done using a beta scintillator.4 The measured radioactive signal represents the time evolution of the sum of all labeled metabolites in the brain. Using a coincidence counter in parallel, an arterial input curve was measured. The 11C at position C-1 of acetate is metabolized in the first turn of the TCA cycle to the position 5 of glutamate (Figure 1A). Through the neurotransmission process, it is further transported to the position 5 of glutamine and the position 5 of neuronal glutamate. After the second turn of the TCA cycle, tracer from [1-11C]acetate (and also a part from glial [5-11C]glutamate) is transferred to glial [1-11C]glutamate and further to [1-11C]glutamine and neuronal glutamate through the neurotransmission cycle. Brain poster session: oxidative mechanisms S460 Journal of Cerebral Blood Flow & Metabolism (2009) 29, S455-S466 Results: The standard acetate two-pool PET model describes the system by a plasma pool and a tissue pool linked by rate constants. Experimental data are not fully described with only one tissue compartment (Figure 1B). The modified NMR model was fitted successfully to tissue time-activity curves from 6 single animals, by varying the glial mitochondrial fluxes and the neurotransmission flux Vnt. A glial composite rate constant Kgtg=Vgtg/[Ace]plasma was extracted. Considering an average acetate concentration in plasma of 1 mmol/g5 and the negligible additional amount injected, we found an average Vgtg = 0.08±0.02 (n = 6), in agreement with previous NMR measurements.1 The tissue time-activity curve is dominated by glial glutamate and later by glutamine (Figure 1B). Labeling of neuronal pools has a low influence, at least for the 20 mins of beta-probe acquisition. Based on the high diffusivity of CO2 across the blood-brain barrier; 11CO2 is not predominant in the total tissue curve, even if the brain CO2 pool is big compared with other metabolites, due to its strong dilution through unlabeled CO2 from neuronal metabolism and diffusion from plasma. Conclusion: The two-compartment model presented here is also able to fit data of positron emission experiments and to extract specific glial metabolic fluxes. 11C-labeled acetate presents an alternative for faster measurements of glial oxidative metabolism compared to NMR, potentially applicable to human PET imaging. However, to quantify the relative value of the TCA cycle flux compared to the transmitochondrial flux, the chemical sensitivity of NMR is required. PET and NMR are thus complementary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D dose reconstruction is a verification of the delivered absorbed dose. Our aim was to describe and evaluate a 3D dose reconstruction method applied to phantoms in the context of narrow beams. A solid water phantom and a phantom containing a bone-equivalent material were irradiated on a 6 MV linac. The transmitted dose was measured by using one array of a 2D ion chamber detector. The dose reconstruction was obtained by an iterative algorithm. A phantom set-up error and organ interfraction motion were simulated to test the algorithm sensitivity. In all configurations convergence was obtained within three iterations. A local reconstructed dose agreement of at least 3% / 3mm with respect to the planned dose was obtained, except in a few points of the penumbra. The reconstructed primary fluences were consistent with the planned ones, which validates the whole reconstruction process. The results validate our method in a simple geometry and for narrow beams. The method is sensitive to a set-up error of a heterogeneous phantom and interfraction heterogeneous organ motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Actively Heated Fiber Optics (AHFO) method to estimate soil moisture is tested and the analysis technique improved on. The measurements were performed in a lysimeter uniformly packed with loam soil with variable water content profiles. In the first meter of the soil profi le, 30 m of fiber optic cable were installed in a 12 loops coil. The metal sheath armoring the fiber cable was used as an electrical resistance heater to generate a heat pulse, and the soil response was monitored with a Distributed Temperature Sensing (DTS) system. We study the cooling following three continuous heat pulses of 120 s at 36 W m(-1) by means of long-time approximation of radial heat conduction. The soil volumetric water contents were then inferred from the estimated thermal conductivities through a specifically calibrated model relating thermal conductivity and volumetric water content. To use the pre-asymptotic data we employed a time correction that allowed the volumetric water content to be estimated with a precision of 0.01-0.035 (m(3) m(-3)). A comparison of the AHFO measurements with soil-moisture measurements obtained with calibrated capacitance-based probes gave good agreement for wetter soils [discrepancy between the two methods was less than 0.04 (m(3) m(-3))]. In the shallow drier soils, the AHFO method underestimated the volumetric water content due to the longertime required for the temperature increment to become asymptotic in less thermally conductive media [discrepancy between the two methods was larger than 0.1 (m(3) m(-3))]. The present work suggests that future applications of the AHFO method should include longer heat pulses, that longer heating and cooling events are analyzed, and, temperature increments ideally be measured with higher frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediment-water exchanges of oxygen, ammonium, nitrate, total dissolved nitrogen, phosphate and total dissolved phosphorus were measured by means of an in situ incubator of 7 1 volume and 700 cm2 base area. The incubations lasted for three hours and were done over a whole season on different kinds of sediments in Alfaques Bay. We present some preliminary results on: i) methodological aspects, ii) spatial and temporal variability of fluxes, and iii) estimates of contribution of benthic nutrient regeneration relative to total nutrient loading of the Bay. Oxygen uptake averaged 1700 mmo1 m-2 h-1 (range 200-3500); no differences were found between sandy and muddy sediments. The release of ammonia from the sediment averaged 70 mmo1 m-2 h-1 and was higher in muddy sediments than in sandy ones. Very low to null nitrate and nitrite fluxes and only small fluxes of organic nitrogen were detected. We conclude that ammonium release from sediment is the major path of nitrogen regeneration. Some sediments removed dissolved reactive phosphorus (DRP) from the water and released dissolved organic phosphorus (DOP). Additional manipulative experiments revealed DRP release under particular conditions (turbulence, anoxia). From these data, we estimate that at least 50% of the nitrogen requirements of phytoplankton in the area may be supplied by benthic remineralization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se describen tres tipos principales de acumulaciones salinas a partir de la interpretación de los perfiles de sísmica de reflexión de las campañas ENIEPSA-MAP-77 (1977) y WESTERN GEOPHYSICAL COMPANY OF AMERICA-MEDS (1973) en el sector norte del surco de Valencia. Los principales tipos de estructuras salinas son rollers de sal, almohadillas y diapiros que se disponen en tres cinturones paralelos al límite de la sal messiniense.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Removal of ice from roads is of the more challenging task in winter highway maintenance. The best mechanical method is to use a truck with underbody plow blade, but such equipment is not available to all agencies charged with winter maintenance operations. While counties and cities often use motor graders to scrape ice, it would be of great benefit if front mounted plows could be used effectively for ice removal. To reveal and understand the factors that influence the performance of these plows, measurement of the forces experienced by the plow blades during ice scraping is desirable. This study explores the possibility of using accelerometers to determine the forces on a front-mounted plow when scraping ice. The plow was modeled by using a dynamic approach. The forces on the plow were to be determined by the measurement of the accelerations of the plow. Field tests were conducted using an "as is" front-mounted plow instrumented with accelerometers. The results of the field tests indicate that in terms of ice removal, the front-mounted plow is not favorable equipment. The major problem in this study is that the front mounted plow was not able to cut ice, and therefore experienced no significant scraping forces. However, the use of accelerometers seems to be promising for analyzing the vibration problems of the front-mounted plow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the more severe winter hazards is ice or compacted snow on roadways. While three methods are typically used to combat ice (salting, sanding and scraping), relatively little effort has been applied to improve methods of scraping ice from roads. In this project, a new test facility has been developed, comprising a truck with an underbody blade, which has been instrumented such that the forces to scrape ice from a pavement can be measured. A test site has been used, which is not accessible to the public, and ice covers have been sprayed onto the pavement and subsequently scraped from it, while the scraping loads have been recorded. Three different cutting edges have been tested for their ice scraping efficiency. Two of the blades are standard (one with a carbide insert, the other without) while the third blade was designed under the SHRP H-204A project. Results from the tests allowed two parameters to be identified. The first is the scraping efficiency which is the ratio of vertical to horizontal force. The lower this ratio, the more efficiently ice is being removed. The second parameter is the scraping effectiveness, which is related (in some as yet unspecified manner) to the horizontal load. The higher the horizontal load, the more ice is being scraped. The ideal case is thus to have as high a horizontal load as possible, combined with the lowest possible vertical load. Results indicate that the SHRP blade removed ice more effectively than the other two blades under equivalent conditions, and furthermore, did so with greater efficiency and thus more control. Furthermore, blade angles close to 0 deg provide for the most efficient scraping for all three blades. The study has shown that field testing of plow blades is possible in controlled situations, and that blades can be evaluated using this system. The system is available for further tests as are deemed appropriate.