353 resultados para rata-ajo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evalulate the applicability of the Revised Diagnostic Criteria for Vogt-Koyanagi-Harada (VKH) disease to Brazilian patients and to verify the association between different disease categories, clinical parameters, and the presence of HLA-DRB1*0405. DESIGN: A retrospective observational case series. METHODS: Medical charts of 67 patients (10 to 64 years in age; 12 men and 55 women), from the Uveitis Service, Hospital das Clinicas, University of Sao Paulo School of Medicine (HCFMUSP), Sao Paulo, Brazil were reviewed. Patients, previously diagnosed with VKH disease using criteria proposed by the American Uveitis Society, underwent retrospective classification based on the Revised Diagnostic Criteria. The degree of concordance was assessed. At presentation, 46 patients (69%) were in the early phase. In this group, the mean time from disease onset to treatment was 15 days (range, one to 30 days). Forty-eight patients (72%) were typed for HLA-DRB1*0405 by polymerase chain reaction-sequence specific primer and polymerase chain reaction,sequence, specific oligonucleotides primer. Disease categories, phase at initial presentation, and ocular complications were analyzed. RESULTS: There was a 100% of concordance between the two criteria. Disease was classified as complete in 10 patients (15%), incomplete in 37 patients (55%), and probable in 20 patients (30%). In each group, respectively, 90%, 76%, and 45% were in the early phase at presentation (P = .017). There was no association between disease categories, the presence of HLA-DRB1*0405, and clinical parameters. CONCLUSION. The Revised Diagnostic Criteria proved useful for diagnosis of VKH disease in Brazilian patients. The present retrospective study did not find any association between disease category and severity parameters. To better understand the relevance of disease categories, a minimum follow-up period to categorize patients should be included in future prospective studies. (Am J Ophthalmol 2009;147:339-345. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the results of a Latin American consensus panel regarding the diagnosis and management of primary open-angle glaucoma and to compare these results with those from a similar panel in the United States. DESIGN: A RAND-like (Research and Development) appropriateness methodology was used to assess glaucoma practice in Latin America. METHODS: The 148 polling statements created for the RAND-like analysis in the United States and 10 additional statements specific to glaucoma care in Latin America were presented to a panel of Latin American glaucoma experts. Panelists were polled in private using the RAND-like methodology before and after the panel meeting. RESULTS: Consensus agreement or disagreement among Latin American experts was reached for 51.3% of statements before the meeting and increased to 66.5% in the private, anonymous meeting after polling (79.0% agreement, 21.0% disagreement). Although there was a high degree of concordance (111 of 148 statements; 75%) between the results of this Latin American panel and the United States panel, there were some notable exceptions relating to diagnostic and therapeutic decision making. CONCLUSIONS: This RAND-like consensus methodology provides a perspective of how Latin American glaucoma practitioners view many aspects of glaucoma and compares these results with those obtained using a similar methodology from practitioners in the United States. These findings may be helpful to ophthalmologists providing glaucoma care in Latin America and in other regions of the world. (Am J Ophthalmol 2012;154: 460-465. (C) 2012 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar a histomorfometria das células intersticiais dos ovários, bem como analisar a concentração sanguínea de esteroides sexuais de ratas portadoras de ovários policísticos induzidos pela luz contínua. MÉTODOS: Vinte ratas foram divididas em dois grupos: ratas na fase de estro (GCtrl ) e ratas portadoras de ovários policísticos induzidos pela iluminação contínua (GOP). Os animais do GCtrl permaneceram com período de luz das 7:00 s 19:00 horas, e os animais do GOP, com iluminação contínua (400 Lux), durante um período de 60 dias. Ao final desse período todos os animais foram anestesiados, foi coletado o sangue, para determinação dos níveis séricos de estradiol (E2), progesterona (P4) e testosterona (T), seguido da retirada dos ovários que foram fixados em formol a 10% e processados para inclusão em parafina. Cortes histológicos com 5 µm corados pela hematoxilina e eosina foram utilizados para análise histomorfométrica. As análises morfológicas, contagem de cistos, determinação da concentração e do volume nuclear das células intersticiais foram realizadas com o auxílio de microscópio de luz adaptado a uma câmera de alta resolução (AxioCam), cujas imagens foram transmitidas e analisadas em computador com software AxioVision Rel 4.8 (Carl Zeiss). Os dados obtidos foram submetidos ao teste t de Student (p<0,05). RESULTADOS: A morfologia mostrou a presença de cistos nos ovários pertencentes ao Grupo OP e de corpos lúteos no GCtrl, mostrando ainda evidências da origem das células intersticiais a partir das células da teca interna desses cistos. Com relação aos níveis hormonais o GOP apresentou níveis séricos de estradiol (pg/mL) aumentados em relação ao GCtrl (GOP=124,9±4,2>GCtrl=73,2±6,5; p<0,05), o mesmo ocorrendo com os níveis de testosterona (pg/mL) (GOP=116,9±4,6>GCtrl=80,6±3,9; p<0,05). Entretanto os níveis de progesterona (ng/mL) foram mais elevados no GCtrl em relação ao GOP (GCtrl=16,3±2,0>GOP=4,2±1,5; p<0,05). A morfometria mostrou haver aumento significante do volume nuclear no grupo GOP (GOP=102,1±5,2>GCtrl=63,6±16,5; p<0,05), assim como da área ocupada (%) pelas células intersticiais (GOP=24,4±6,9>GCtrl=6,9±3,2; p<0,05) em relação aos animais do GCtrl. CONCLUSÃO: As células intersticiais do ovário policístico da rata provavelmente provêm dos cistos ovarianos devido degeneração das células da granulosa e diferenciação das células da teca interna. As elevações dos níveis séricos de testosterona e de estradiol provavelmente provêm do aumento significativo da atividade celular e da área ocupada pelas células intersticiais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il prosciutto cotto è un alimento presente nella dieta degli italiani, che lo consumano più di ogni altro salume. Il D. M. del 21/09/2005, che ne disciplina produzione e vendita, lo classifica in tre diverse categorie merceologiche (Prosciutto cotto o Standard, Prosciutto cotto Scelto, Prosciutto cotto Alta Qualità). Il lavoro svolto presso il Dipartimento di Scienze e Tecnologie Agro-Alimentari dell’Università di Bologna su 92 consumatori di prosciutto cotto ha permesso di studiare abitudini, gusti, aspettative dei soggetti intervistati e di verificare la loro capacità di distinguere prosciutti cotti appartenenti alle differenti categorie. A tale scopo è stato progettato un questionario strutturato secondo il modello RATA con una sezione per valutare i profili emozionali dei prodotti in esame conforme al metodo EmoSemio. Il gruppo di consumatori intervistati era composto da soggetti con età compresa tra 19 e 70 anni, frequenza di consumo di prosciutto cotto pari a 1-3 volte al mese e maggior familiarità con l’Alta Qualità. I risultati ottenuti hanno evidenziato l’ottima capacità percettiva dei consumatori, che hanno descritto i campioni in modo analogo al panel di esperti, che in precedenza aveva valutato gli stessi campioni. La chiara discriminazione riscontrata da parte dei consumatori tra i prosciutti Standard e Alta Qualità, però, non sempre si è tradotta in una preferenza per il prodotto della categoria migliore. I risultati relativi alla valutazione dello stato emozionale erano in linea con il gradimento: per i prodotti più graditi l’intensità delle emozioni positive era più alta. Infine, quasi tutti gli attributi scelti dal panel sono stati compresi e valutati allo stesso modo dai consumatori, risultando efficaci e, talora, comunicabili. Questo studio ha contribuito a fornire gli elementi per la comprensione del profilo di gradimento del prosciutto cotto al consumo ed ha confermato l'utilità del metodo RATA e dell’EmoSemio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the intraoperative use of handheld Fourier-domain optical coherence tomography (OCT) during Descemet stripping automated endothelial keratoplasty (DSAEK) to assess the donor-host interface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To report refractive, topographic, aberrometric, and tomographic outcomes 24 months after corneal cross-linking (CXL) in patients up to 18 years of age with progressive keratoconus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe a case series of neovascular glaucoma (NVG) caused by central retinal vein occlusion (CRVO) that was treated with intravitreal bevacizumab (IVB; Avastin). DESIGN: Retrospective interventional case series. METHODS: Six consecutive patients with NVG and a refractory, symptomatic elevation of intraocular pressure (IOP) and pronounced anterior segment congestion received IVB (1.25 mg/0.05 ml). Diode laser cyclophotocoagulation was carried out only if pressure was controlled insufficiently by topical medication. Follow-up examinations occurred at four to 16 weeks. RESULTS: IVB resulted in a marked regression of anterior segment neovascularization and relief of symptoms within 48 hours. IOP decreased substantially in three eyes; in the other three eyes, adjuvant cyclophotocoagulation was necessary. No side effects were observed. Panretinal photocoagulation (PRP) was performed as soon as feasible, five to 12 weeks after IVB treatment. CONCLUSION: IVB leads to a rapid regression of iris and angle neovascularization and should be investigated more thoroughly as an adjunct in the management of NVG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To demonstrate not only prevention of vision loss but also improvement in best-corrected visual acuity (BCVA) after treatment with ranibizumab on a variable-dosing regimen over 24 months in patients with age-related macular degeneration (AMD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the effect of intravitreal and orbital floor triamcinolone acetonide (TA) on macular edema, visual outcome, and course of postoperative inflammation after cataract surgery in uveitis patients. DESIGN: Prospective, randomized clinical trial. METHODS: Monocenter study (40 patients) with chronic endogenous uveitis who underwent phacoemulsification with intraocular lens implantation with either 4 mg intravitreal TA (n = 20) or 40 mg orbital floor TA (n = 20). The primary outcome was influence on cystoid macular edema (CME). Secondary outcome measures were best-corrected visual acuity (BCVA), anterior chamber cell grade, laser flare photometry, giant cell deposition, posterior capsule opacification (PCO), and intraocular pressure. RESULTS: Mean central foveal thickness decreased in the intravitreal TA group and increased in the orbital floor TA group (P < .001 at one and three months). CME improved in 50% of patients after intravitreal TA, whereas it was unchanged after orbital floor TA (difference between the groups at three months, P = .049). Mean BCVA (logarithm of the minimal angle of resolution) improved postoperatively (P < .001) from 0.76 and 0.74 to 0.22 and 0.23 in the intravitreal TA and orbital floor TA group, respectively. Anterior chamber cell count at one month was lower in the intravitreal TA than in the orbital floor TA group (P = .02). Laser flare photometry values and giant cell numbers were slightly higher after orbital floor TA than after intravitreal TA. The groups did not differ with respect to PCO rate and ocular hypertension. CONCLUSIONS: The CME improvement and anti-inflammatory effect after intravitreal TA was better than after orbital floor TA injection in cataract surgery in uveitis patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To test the reproducibility of retinal thickness measurements in healthy volunteers of a new Frequency-domain optical coherence tomography (OCT) device (Spectralis OCT; Heidelberg Engineering, Heidelberg, Germany). DESIGN: Prospective, observational study. METHODS: Forty-one eyes of 41 healthy subjects were included into the study. Intraobserver reproducibility was tested with 20 x 15 degree raster scans consisting of 37 high-resolution line scans that were repeated three times by one examiner (M.N.M.). Mean retinal thickness was calculated for nine areas corresponding to the Early Treatment Diabetic Retinopathy Study (ETDRS) areas. Coefficients of variation (COV) were calculated. RESULTS: Retinal thickness measurements were highly reproducible for all ETDRS areas. Mean total retinal thickness was 342 +/- 15 microm. Mean foveal thickness was 286 +/- 17 microm. COVs ranged from 0.38% to 0.86%. Lowest COV was found for the temporal outer ETDRS area (area 7; COV, 0.38%). Highest COV was found for the temporal inner ETDRS area (area 3; COV, 0.86%). Mean difference between measurement 1 and 2, measurement 1 and 3, and measurement 2 and 3 for all ETDRS areas was 1.01 microm, 0.98 microm, and 0.99 microm, respectively. CONCLUSION: Spectralis OCT retinal thickness measurements in healthy volunteers showed excellent intraobserver reproducibility with virtually identical results between retinal thickness measurements performed by one operator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The objective of this trial was to compare the survival rates of mandibular lingual retainers bonded with either chemically cured or light-cured adhesive after orthodontic treatment. METHODS Patients having undergone orthodontic treatment at a private orthodontic office were randomly allocated to fixed retainers placed with chemically cured composite or light-cured composite. Eligibility criteria included no active caries, restorations, or fractures on the mandibular anterior teeth, and adequate oral hygiene. The main outcome was any type of first-time lingual retainer breakage; pattern of failure (adapted adhesive remnant index scores) was a secondary outcome. Randomization was accomplished with random permuted blocks of 20 patients with allocation concealed in sequentially numbered, opaque, sealed envelopes. Blinding was applicable for outcome assessment only. Patients were reviewed at 1, 3, and 6 months and then every 6 months after placement of the retainer until completion of the study. Data were analyzed using survival analysis including Cox regression; sensitivity analysis was carried out after data imputation for subjects lost to follow-up. RESULTS Two hundred twenty patients (median age, 16 years; interquartile range, 2; range, 12-47 years) were randomized in a 1:1 ratio to either chemical or light curing. Baseline characteristics were similar between groups, the median follow-up period was 2.19 years (range, 0.003-3.64 years), and 16 patients were lost to follow-up. At a minimum follow-up of 2 years, 47 of 110 (42.7%) and 55 of 110 (50.0%) retainers had some type of failure with chemically cured and light-cured adhesive, respectively (log-rank test, P = 0.35). Data were analyzed on an intention-to-treat basis, and the hazard ratio (HR) was 1.15 (95% confidence interval [CI], 0.88-1.70; P = 0.47). There was weak evidence that age is a significant predictor for lingual retainer failures (HR, 0.96; 95% CI, 0.93-1.00; P = 0.08). Adhesive remnant index scoring was possible for only 66 of the 102 (64.7%) failures and did not differ between composites (Fisher exact test, P = 0.16). No serious harm was observed other than gingivitis associated with plaque accumulation. CONCLUSIONS The results of this study indicated no evidence that survival of mandibular lingual retainers differs between chemically and light-cured adhesives. The overall failure rate was 46.4%; however, this included any type of failure, which may have exaggerated the overall failure rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The objective of this systematic review was to assess the short- and long-term release of components of orthodontic adhesives and polycarbonate brackets in the oral environment. METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS No randomized controlled trial was identified. In the absence of randomized controlled trials, observational studies were included. Eleven studies met the inclusion criteria. All were observational studies conducted in vivo or in vitro. The bisphenol-A release from orthodontic bonding resins was found to be between 0.85 and 20.88 ng per milliliter in vivo, and from traces to 65.67 ppm in vitro. Polycarbonate brackets released amounts of 22.24 μg per gram in ethanol solution and 697 μg per gram after 40 months in water. Bis-GMA and TEGDMA leaching in vitro reached levels of 64 and 174 mg per 10 μL, respectively. Because of the heterogeneity in methodologies and reporting, only qualitative synthesis was performed. CONCLUSIONS The available evidence on this topic derived from observational in-vivo and in-vitro studies that represent a moderate level of evidence. The variety of setups and the different units allied to the diversity of reporting among studies did not allow calculation of pooled estimates.