971 resultados para radiation treatment margins


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alveolar echinococcosis is caused by the metacestode stage of the fox tapeworm Echinococcus multilocularis. Current chemotherapeutical options for the treatment of echinococcosis are not satisfactory, and novel drugs and/or other potential means of therapy are needed. E. multilocularis metacestodes are characterized by almost potentially unlimited growth, and also display other features of cancerous tumours. In this study, we exposed metacestodes that were generated in vitro to 50-100 Gy ionizing irradiation, and subsequently investigated the short-term (10-12 days post-treatment) and long-term (14 weeks post-treatment) effects. We found, that in the short-term, no release of alkaline phosphatase (EmAP) activity as a measure for potentially induced damage and loss of viability could be detected, and that the protein expression pattern and protease activities in vesicle fluids and medium supernatants did not alter dramatically following irradiation. However, irradiation was associated with distinct morphological and ultrastructural alterations in the tissue of metacestodes, affecting most notably cell-cell contacts, mitochondrial shape, glycogen-storage cells and lipid droplet formation. These could be detected already at 10 days following treatment and remained as such also in the long-term. In addition, as determined after 14 weeks of culture, irradiation affected the proliferation and the growth of E. multilocularis metacestodes. Thus, we demonstrate that radiotherapy does not have a clear-cut parasitocidal effect, but can lead to metabolic impairment of E. multilocularis metacestodes, as reflected by the distinct morphological and structural alterations induced by irradiation treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microbeam radiation therapy (MRT), a preclinical form of radiosurgery, uses spatially fractionated micrometre-wide synchrotron-generated X-ray beams. As MRT alone is predominantly palliative for animal tumors, the effects of the combination of MRT and a newly synthesized chemotherapeutic agent JAI-51 on 9L gliosarcomas have been evaluated. Fourteen days (D14) after implantation (D0), intracerebral 9LGS-bearing rats received either MRT, JAI-51 or both treatments. JAI-51, alone or immediately after MRT, was administered three times per week. Animals were kept up to ∼20 weeks after irradiation or sacrificed at D16 or D28 after treatment for cell cycle analysis. MRT plus JAI-51 increased significantly the lifespan compared with MRT alone (p = 0.0367). JAI-51 treatment alone had no effect on rat survival. MRT alone or associated with JAI-51 induced a cell cycle blockade in G2/M (p < 0.01) while the combined treatment also reduced the proportion of G0/G1 cells. At D28 after irradiation, MRT and MRT/JAI-51 had a smaller cell blockade effect in the G2/M phase owing to a significant increase in tumor cell death rate (<2c) and a proportional increase of endoreplicative cells (>8c). The combination of MRT and JAI-51 increases the survival of 9LGS-bearing rats by inducing endoreduplication of DNA and tumor cell death; further, it slowed the onset of tumor growth resumption two weeks after treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The goal of our work was to develop a simple method to evaluate a compensation treatment after unplanned treatment interruptions with respect to their tumour- and normal tissue effect. Methods We developed a software tool in java programming language based on existing recommendations to compensate for treatment interruptions. In order to express and visualize the deviations from the originally planned tumour and normal tissue effects we defined the compensability index. Results The compensability index represents an evaluation of the suitability of compensatory radiotherapy in a single number based on the number of days used for compensation and the preference of preserving the originally planned tumour effect or not exceeding the originally planned normal tissue effect. An automated tool provides a method for quick evaluation of compensation treatments. Conclusions The compensability index calculation may serve as a decision support system based on existing and established recommendations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. To assess the role of adjuvant androgen deprivation therapy (ADT) in high-risk prostate cancer patients (PCa) after surgery. Materials and Methods. The analysis case matched 172 high-risk PCa patients with positive section margins or non-organ confined disease and negative lymph nodes to receive adjuvant ADT (group 1, n = 86) or no adjuvant ADT (group 2, n = 86). Results. Only 11.6% of the patients died, 2.3% PCa related. Estimated 5-10-year clinical progression-free survival was 96.9% (94.3%) for group 1 and 73.7% (67.0%) for group 2, respectively. Subgroup analysis identified men with T2/T3a tumors at low-risk and T3b margins positive disease at higher risk for progression. Conclusion. Patients with T2/T3a tumors are at low-risk for metastatic disease and cancer-related death and do not need adjuvant ADT. We identified men with T3b margin positive disease at highest risk for clinical progression. These patients benefit from immediate adjuvant ADT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the incidence and diagnostic difficulties of radionecrosis vs tumor recurrence of laryngeal and hypopharyngeal carcinomas. STUDY DESIGN AND SETTING: Retrospective study on 341 patients treated by radiation alone or radiochemotherapy. The clinicopathologic findings, work-up, treatment, and follow-up of 20 patients with symptoms suggestive but negative for tumor recurrence on initial imaging studies and endoscopy were analyzed. RESULTS: The incidence of chondroradionecrosis in 341 irradiated patients was 5%. Ten of 20 patients initially negative for tumor recurrence were treated by total laryngectomy; in all laryngectomy specimens, chondroradionecrosis was present, in six specimens associated with tumor recurrence. Ten patients were treated by tracheotomy and tumor recurrence was detected in one patient during follow-up. CONCLUSION: Chondroradionecrosis is a relatively rare treatment complication. Typical imaging findings suggestive of radionecrosis are often missing. Tumor recurrence may be present beneath an intact mucosa and missed by endoscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The benefit of postoperative radiation for advanced primary parotid carcinoma has been reported previously, whereas studies to evaluate the usefulness of postoperative radiation for T1 and T2 parotid carcinomas have never been performed. STUDY DESIGN AND SETTING: Retrospective analysis on 58 previously untreated patients with T1 and T2 parotid carcinomas. In 34 patients, postoperative radiation was included in the treatment protocol and in 24 patients, no postoperative radiation was applied. RESULTS: A local recurrence was observed in 8 of 24 (33%) patients without and in 1 of 34 (3%) patients with postoperative radiation (P < 0.5). The 5-year actuarial and disease-free survival rate was 83% and 70% for patients without postoperative radiation and 93% and 92% for patients with postoperative radiation. CONCLUSION AND SIGNIFICANCE: Local recurrence was less often observed in patients with postoperative radiation. Nevertheless, prospective randomized studies are needed to confirm the usefulness of postoperative radiation in early carcinomas. EBM rating: B-3b.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Supraomohyoid neck dissection (SOHND) is currently performed in patients with carcinoma of the oral cavity with clinically negative neck. Most investigators consider SOHND as a staging procedure. METHODS: Records of 100 patients with cancer of the oral cavity and clinically negative neck undergoing SOHND were reviewed. The rate and significance of occult metastases are evaluated, the neck recurrences are analyzed and the indication of adjuvant radiation of pN+ necks is discussed. RESULTS: In 34 of 1814 of analyzed lymph nodes, metastatic disease was detected as follows: 30 macrometastases and 4 micrometastases. In 13 of 34 metastases (38%), extracapsular spread was observed. Twenty of 100 patients (20%) had to be upstaged. In 9 of 87 (10%) patients without local recurrence and with a minimal follow-up of 24 months, 5 ipsilateral (4 within the dissection field) and 5 contralateral neck recurrences were observed. Regional recurrence developed in 4% and 35% of patients with pN0 and pN+ necks, respectively. CONCLUSIONS: In 20% of patients with oral cavity tumors and pN0 neck, occult metastases were disclosed. Neck recurrences developed significantly more often in patients with pN+ than in those with pN0 necks. To evaluate the exact indication for an adjuvant treatment of patients with cN0/pN+ necks, prospective studies should be performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Malignant glial brain tumors consistently overexpress neurokinin type 1 receptors. In classic seed-based brachytherapy, one to several rigid (125)I seeds are inserted, mainly for the treatment of small low-grade gliomas. The complex geometry of rapidly proliferating high-grade gliomas requires a diffusible system targeting tumor-associated surface structures to saturate the tumor, including its margins. EXPERIMENTAL DESIGN: We developed a new targeting vector by conjugating the chelator 1,4,7,10-tetraazacyclododecane-1-glutaric acid-4,7,10-triacetic acid to Arg(1) of substance P, generating a radiopharmaceutical with a molecular weight of 1,806 Da and an IC(50) of 0.88 +/- 0.34 nmol/L. Cell biological studies were done with glioblastoma cell lines. neurokinin type-1 receptor (NK1R) autoradiography was done with 58 tumor biopsies. For labeling, (90)Y was mostly used. To reduce the "cross-fire effect" in critically located tumors, (177)Lut and (213)Bi were used instead. In a pilot study, we assessed feasibility, biodistribution, and early and long-term toxicity following i.t. injection of radiolabeled 1,4,7,10-tetraazacyclododecane-1-glutaric acid-4,7,10-triacetic acid substance P in 14 glioblastoma and six glioma patients of WHO grades 2 to 3. RESULTS: Autoradiography disclosed overexpression of NK1R in 55 of 58 gliomas of WHO grades 2 to 4. Internalization of the peptidic vector was found to be specific. Clinically, the radiopharmeutical was distributed according to tumor geometry. Only transient toxicity was seen as symptomatic radiogenic edema in one patient (observation period, 7-66 months). Disease stabilization and/or improved neurologic status was observed in 13 of 20 patients. Secondary resection disclosed widespread radiation necrosis with improved demarcation. CONCLUSIONS: Targeted radiotherapy using diffusible peptidic vectors represents an innovative strategy for local control of malignant gliomas, which will be further assessed as a neoadjuvant approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently photon Monte Carlo treatment planning (MCTP) for a patient stored in the patient database of a treatment planning system (TPS) can usually only be performed using a cumbersome multi-step procedure where many user interactions are needed. This means automation is needed for usage in clinical routine. In addition, because of the long computing time in MCTP, optimization of the MC calculations is essential. For these purposes a new graphical user interface (GUI)-based photon MC environment has been developed resulting in a very flexible framework. By this means appropriate MC transport methods are assigned to different geometric regions by still benefiting from the features included in the TPS. In order to provide a flexible MC environment, the MC particle transport has been divided into different parts: the source, beam modifiers and the patient. The source part includes the phase-space source, source models and full MC transport through the treatment head. The beam modifier part consists of one module for each beam modifier. To simulate the radiation transport through each individual beam modifier, one out of three full MC transport codes can be selected independently. Additionally, for each beam modifier a simple or an exact geometry can be chosen. Thereby, different complexity levels of radiation transport are applied during the simulation. For the patient dose calculation, two different MC codes are available. A special plug-in in Eclipse providing all necessary information by means of Dicom streams was used to start the developed MC GUI. The implementation of this framework separates the MC transport from the geometry and the modules pass the particles in memory; hence, no files are used as the interface. The implementation is realized for 6 and 15 MV beams of a Varian Clinac 2300 C/D. Several applications demonstrate the usefulness of the framework. Apart from applications dealing with the beam modifiers, two patient cases are shown. Thereby, comparisons are performed between MC calculated dose distributions and those calculated by a pencil beam or the AAA algorithm. Interfacing this flexible and efficient MC environment with Eclipse allows a widespread use for all kinds of investigations from timing and benchmarking studies to clinical patient studies. Additionally, it is possible to add modules keeping the system highly flexible and efficient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response necessitates predictive models of respiratory tumor motion to synchronize radiation delivery. Predicting a complex process such as respiratory motion introduces geometric errors, which have been reported in several publications. However, the dosimetric effect of such errors on 4D radiation delivery has not yet been investigated. Thus, our aim in this work was to quantify the dosimetric effects of geometric error due to prediction under several different conditions. Conformal and intensity modulated radiation therapy (IMRT) plans for a lung patient were generated for anterior-posterior/posterior-anterior (AP/PA) beam arrangements at 6 and 18 MV energies to provide planned dose distributions. Respiratory motion data was obtained from 60 diaphragm-motion fluoroscopy recordings from five patients. A linear adaptive filter was employed to predict the tumor position. The geometric error of prediction was defined as the absolute difference between predicted and actual positions at each diaphragm position. Distributions of geometric error of prediction were obtained for all of the respiratory motion data. Planned dose distributions were then convolved with distributions for the geometric error of prediction to obtain convolved dose distributions. The dosimetric effect of such geometric errors was determined as a function of several variables: response time (0-0.6 s), beam energy (6/18 MV), treatment delivery (3D/4D), treatment type (conformal/IMRT), beam direction (AP/PA), and breathing training type (free breathing/audio instruction/visual feedback). Dose difference and distance-to-agreement analysis was employed to quantify results. Based on our data, the dosimetric impact of prediction (a) increased with response time, (b) was larger for 3D radiation therapy as compared with 4D radiation therapy, (c) was relatively insensitive to change in beam energy and beam direction, (d) was greater for IMRT distributions as compared with conformal distributions, (e) was smaller than the dosimetric impact of latency, and (f) was greatest for respiration motion with audio instructions, followed by visual feedback and free breathing. Geometric errors of prediction that occur during 4D radiation delivery introduce dosimetric errors that are dependent on several factors, such as response time, treatment-delivery type, and beam energy. Even for relatively small response times of 0.6 s into the future, dosimetric errors due to prediction could approach delivery errors when respiratory motion is not accounted for at all. To reduce the dosimetric impact, better predictive models and/or shorter response times are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radiation dose delivered from the SCANORA radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasound (US) is an emerging imaging technique in interventional pain management. The main advantages are the identification of soft tissues, vessels, and nerves, without exposing patients and personnel to radiation, the possibility to perform continuous imaging, and the visualization of the fluid injected in a real-time fashion. Possible applications are nerve blocks of the cervical and lumbar zygapophysial joints, stellate ganglion block, intercostal nerve blocks, occipital nerve blocks, blocks of the inguinal nerves, peripheral nerve blocks of the extremities, blocks of painful stump neuromas, caudal epidural injections, and injections of tender points. US may also be used for destructive procedures, such as cryoanalgesia, radiofrequency lesions, or chemical neurolysis. The increasing published data available suggest that US has a potential usefulness in interventional pain management, but also limitations. There is still a need for clinical trials investigating efficacy and safety of US-guided pain procedures. Until these studies are made, fluoroscopy or computed tomography remain the gold standard for most interventional pain procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To report acute and late toxicity in prostate cancer patients treated by dose escalated intensity-modulated radiation therapy (IMRT) and organ tracking. METHODS: From 06/2004 to 12/2005 39 men were treated by 80 Gy IMRT along with organ tracking. Median age was 69 years, risk of recurrence was low 18%, intermediate 21% and high in 61% patients. Hormone therapy (HT) was received by 74% of patients. Toxicity was scored according to the CTC scale version 3.0. Median follow-up (FU) was 29 months. RESULTS: Acute and maximal late grade 2 gastrointestinal (GI) toxicity was 3% and 8%, late grade 2 GI toxicity dropped to 0% at the end of FU. No acute or late grade 3 GI toxicity was observed. Grade 2 and 3 pre-treatment genitourinary (GU) morbidity (PGUM) was 20% and 5%. Acute and maximal late grade 2 GU toxicity was 56% and 28% and late grade 2 GU toxicity decreased to 15% of patients at the end of FU. Acute and maximal late grade 3 GU toxicity was 8% and 3%, respectively. Decreased late > or = grade 2 GU toxicity free survival was associated with higher age (P = .025), absence of HT (P = .016) and higher PGUM (P < .001). DISCUSSION: GI toxicity rates after IMRT and organ tracking are excellent, GU toxicity rates are strongly related to PGUM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tumors of the pineal region are uncommon, comprising approximately 0.4-1% of all intracranial tumors in adults in European and American series. Histopathologically, they are a very heterogeneous group of tumors. Of genuine pineal tumors, pineal parenchymal tumors of intermediate differentiation (PPTIDs) are the least frequently found type. In this paper, we report on the case of a patient with an unexpected and difficult-to-diagnose PPTID. A 2.2 x 2.2-cm midline mass within the posterior part of the third ventricle with consecutive obstructive hydrocephalus was found in a 44-year-old man presenting with diplopia and gait disturbances. There was no clear connection of the tumor to the pineal gland. Differential diagnosis included all intraventricular and midline tumors, therefore a biopsy was taken. Preliminary histopathological diagnosis was germinoma or primitive neuroectodermal tumor, and the tissue sample was reexamined by a referential neuropathological institute. Final diagnosis was PPTID. The tumor was then resected through a transventricular/transchoroidal approach. Histopathological examination of tumor specimen confirmed the diagnosis of a PPTID. Postoperatively, the patient received gamma-knife radiosurgery. At 1-year follow-up, there are no signs of tumor regrowth. Diagnosis of pineal parenchymal tumors in general and PPTIDs in particular can be troublesome. Their histopathological features are still being defined, as is the biological behavior of the different tumor entities. Thus, treatment options including surgery, radiation therapy, and chemotherapy remain controversial. We recommend surgical removal of PPTID, preferably in toto whenever the size of the tumor permits that kind of excision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: There were 373 patients irradiated after breast conserving carcinoma treatment. A planning computed tomography revealed in 97 of these patients seromas and tissue defects exceeding 2cm in diameter. The cosmetic results in those patients and the impact of seromas herein had to be evaluated. PATIENTS AND METHODS: Mean age was 59 years. A quadrant resection was performed in 17.5 percent of the patients, a segmental resection in 27.8 percent and a tumour excision in 54.6 percent. Radiation therapy was applied with the Linear accelerator and 6 MeV photons up to a total dose in the residual breast of 50 Gy followed by a boost dose to the former tumour bed of 10 Gy. A distinct evaluation and documentation of therapy related side effects and the resulting cosmesis was done in 51 patients. RESULTS: In all the examined seroma patients there were moderate acute skin reactions grade 1 to 3. As late effects in 82.3 percent scar indurations were noticed. At the skin 51 percent showed enhanced pigmentation, 68.6 percent atrophia and only 11 percent teleangiectasia. Subcutaneous fibrosis occurred in 56,9 percent of the patients, 78.4 percent of the women had breast asymmetries. In 41.2 percent there were a lymphedema subcutaneously, in 72.5 percent impaired sensibility. The overall cosmetic result documented with a 5 point score was "very good" (score 1) in 19.6 percent and "good" (score 2) in 33.3 percent, 37.3 percent were "satisfactory" (score 3) and 9.8 percent "bad" (score 4) respectively. No "very bad" results (score 5) were seen. CONCLUSIONS: The cosmetic results in the examined group of seroma and hematoma patients were inferior to those reported in the literature. We conclude that postoperative seroma and hematoma have an adverse effect on the resulting cosmesis and that their frequency and extent have to be reduced in future by the responsible surgeons.