964 resultados para onshore AC grid
Resumo:
Notification Services mediate between information publishers and consumers that wish to subscribe to periodic updates. In many cases, however, there is a mismatch between the dissemination of these updates and the delivery preferences of the consumer, often in terms of frequency of delivery, quality, etc. In this paper, we present an automated negotiation engine that identifies mutually acceptable terms; we study its performance, and discuss its application to a Grid Notification Service. We also demonstrate how the negotiation engine enables users to control the Quality of Service levels they require.
Resumo:
Notification Services mediate between information publishers and consumers that wish to subscribe to periodic updates. In many cases, however, there is a mismatch between the dissemination of these updates and the delivery preferences of the consumer, often in terms of frequency of delivery, quality, etc. In this paper, we present an automated negotiation engine that identifies mutually acceptable terms; we study its performance, and discuss its application to a Grid Notification Service. We also demonstrate how the negotiation engine enables users to control the Quality of Service levels they require.
Resumo:
Two-stage isolated converters for photovoltaic (PV) applications commonly employ a high-frequency transformer on the DC-DC side, submitting the DC-AC inverter switches to high voltages and forcing the use of IGBTs instead of low-voltage and low-loss MOSFETs. This paper shows the modeling, control and simulation of a single-phase full-bridge inverter with high-frequency transformer (HFT) that can be used as part of a two-stage converter with transformerless DC-DC side or as a single-stage converter (simple DC-AC inverter) for grid-connected PV applications. The inverter is modeled in order to obtain a small-signal transfer function used to design the PResonant current control regulator. A high-frequency step-up transformer results in reduced voltage switches and better efficiency compared with converters in which the transformer is used on the DC-DC side. Simulations and experimental results with a 200 W prototype are shown. © 2012 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Renewable energy hybrid systems and mini-grids for electrification of rural areas are known to be reliable and more cost efficient than grid extension or only-diesel based systems. However, there is still some uncertainty in some areas, for example, which is the most efficient way of coupling hybrid systems: AC, DC or AC-DC? With the use of Matlab/Simulink a mini-grid that connects a school, a small hospital and an ecotourism hostel has been modelled. This same mini grid has been coupled in the different possible ways and the system’s efficiency has been studied. In addition, while keeping the consumption constant, the generation sources and the consumption profile have been modified and the effect on the efficiency under each configuration has also been analysed. Finally different weather profiles have been introduced and, again, the effect on the efficiency of each system has been observed.
Resumo:
This study develops a proposal of method of calculation useful to estimate the energy produced by a PV grid-connected system making use of irradiance-domain integrals and denition of statistical moment. Validation against database of real PV plants performance data shows that acceptable energy estimation can be obtained with rst to fourth statistical moments and some basic system parameters. This way, only simple calculations at the reach of pocket calculators, are enough to estimate AC energy.
Resumo:
This paper presents a comprehensive review of stepup single-phase non-isolated inverters suitable for ac-module applications. In order to compare the most feasible solutions of the reviewed topologies, a benchmark is set. This benchmark is based on a typical ac-module application considering the requirements for the solar panels and the grid. The selected solutions are designed and simulated complying with the benchmark obtaining passive and semiconductor components ratings in order to perform a comparison in terms of size and cost. A discussion of the analyzed topologies regarding the obtained ratings as well as ground currents is presented. Recommendations for topological solutions complying with the application benchmark are provided.
Resumo:
This paper presents a primary-parallel secondaryseries multicore forward microinverter for photovoltaic ac-module application. The presented microinverter operates with a constant off-time boundary mode control, providing MPPT capability and unity power factor. The proposed multitransformer solution allows using low-profile unitary turns ratio transformers. Therefore, the transformers are better coupled and the overall performance of the microinverter is improved. Due to the multiphase solution, the number of devices increases but the current stress and losses per device are reduced contributing to an easier thermal management. Furthermore, the decoupling capacitor is split among the phases, contributing to a low-profile solution without electrolytic capacitors suitable to be mounted in the frame of a PV module. The proposed solution is compared to the classical parallel-interleaved approach, showing better efficiency in a wide power range and improving the weighted efficiency.
Resumo:
The electric vehicle (EV) market has seen a rapid growth in the recent past. With an increase in the number of electric vehicles on road, there is an increase in the number of high capacity battery banks interfacing the grid. The battery bank of an EV, besides being the fuel tank, is also a huge energy storage unit. Presently, it is used only when the vehicle is being driven and remains idle for rest of the time, rendering it underutilized. Whereas on the other hand, there is a need of large energy storage units in the grid to filter out the fluctuations of supply and demand during a day. EVs can help bridge this gap. The EV battery bank can be used to store the excess energy from the grid to vehicle (G2V) or supply stored energy from the vehicle to grid (V2G ), when required. To let power flow happen, in both directions, a bidirectional AC-DC converter is required. This thesis concentrates on the bidirectional AC-DC converters which have a control on power flow in all four quadrants for the application of EV battery interfacing with the grid. This thesis presents a bidirectional interleaved full bridge converter topology. This helps in increasing the power processing and current handling capability of the converter which makes it suitable for the purpose of EVs. Further, the benefit of using the interleaved topology is that it increases the power density of the converter. This ensures optimization of space usage with the same power handling capacity. The proposed interleaved converter consists of two full bridges. The corresponding gate pulses of each switch, in one cell, are phase shifted by 180 degrees from those of the other cell. The proposed converter control is based on the one-cycle controller. To meet the challenge of new requirements of reactive power handling capabilities for grid connected converters, posed by the utilities, the controller is modified to make it suitable to process the reactive power. A fictitious current derived from the grid voltage is introduced in the controller, which controls the converter performance. The current references are generated using the second order generalized integrators (SOGI) and phase locked loop (PLL). A digital implementation of the proposed control ii scheme is developed and implemented using DSP hardware. The simulated and experimental results, based on the converter topology and control technique discussed here, are presented to show the performance of the proposed theory.
Resumo:
Grid connected PhotoVoltaic (PV) inverters fall into three broad categories — Central, String and Module Integrated Converers (MICs). MICs offer any avantaes in performance and flexibility, but are at a cost disadvantage. Two alternative novel approaches proposed by the author — cascaded dc-dc MICs and bypass dc-dc MICs — integrate a simple non-isolated intelligent dc-dc converter with each PV module to provide the advantages of dc-ac MICs at a lower cost. A suitable universal 150W 5A dc-dc converter design is presented based on two interleaved MOSFET half bridges. Testing shows Zero Voltage Switching (ZVS) keeps losses under 1W for bi-directional power flows up to 15W between two adjacent 12V PV modules for the bypass application, and efficiencies over 94% for most of the operational power range for the cascaded converter application. Based on the experimental results, potential optimizations to further reduce losses are discussed.
Resumo:
The thesis provides a comparative study of both sedimentology and diagenesis of Lower Permian (Rotliegend) strata, onshore and offshore U.K. (Southern North Sea). Onshore formations studied include the Bridgnorth, Penrith and Hopeman Sandstone, and are dominated by aeolian facies, with lesser amounts of interbedded fluvial sediments. Aeolian and fluvial strata in onshore basins typically grade laterally into alluvial fan breccias at basin margins. Onshore basins represent proximal examples of Rotliegend desert sediments. The Leman Sandstone Formation of the Ravenspurn area in the Southern North Sea displays a variety of facies indicative of a distal sedimentological setting; Aeolian, fluvial, sabkha, and playa lake sediments all being present. "Sheet-like" geometry of stratigraphical units within the Leman Sandstone, and alternation of fluvial and aeolian deposition was climatically controlled. Major first order bounding surfaces are laterally extensive and were produced by lacustrine transgression and regression from the north-west. Diagenesis within Permian strata was studied using standard petrographic microscopy, scanning electron microscopy, cold cathodo-Iuminescence, X-ray diffraction clay analysis, X-ray fluorescence spectroscopy, fluid inclusion microthermometry, and K-Ar dating of illites. The diagenesis of Permian sediments within onshore basins is remarkably similar, and a paragenetic sequence of early haematite, illitic clays, feldspar, kaolinite, quartz and late calcite is observed. In the Leman Sandstone formation, authigenic mineralogy is complex and includes early quartz, sulphates and dolomite, chlorite, kaolinite, late quartz, illite and siderite. Primary lithological variation, facies type, and the interdigitation and location of facies within a basin are important initial controls upon diagenesis. Subsequently, burial history, structure, the timing of gas emplacement, and the nature of sediments within underlying formations may also exersize significant controls upon diagenesis within Rotliegend strata.