998 resultados para news detection
Resumo:
Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.
Resumo:
One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.
Resumo:
Recent studies of mobile Web trends show a continuous explosion of mobile-friendly content. However, the increasing number and heterogeneity of mobile devices poses several challenges for Web programmers who want to automatically get the delivery context and adapt the content to mobile devices. In this process, the devices detection phase assumes an important role where an inaccurate detection could result in a poor mobile experience for the enduser. In this paper we compare the most promising approaches for mobile device detection. Based on this study, we present an architecture for a system to detect and deliver uniform m-Learning content to students in a Higher School. We focus mainly on the devices capabilities repository manageable and accessible through an API. We detail the structure of the capabilities XML Schema that formalizes the data within the devices capabilities XML repository and the REST Web Service API for selecting the correspondent devices capabilities data according to a specific request. Finally, we validate our approach by presenting the access and usage statistics of the mobile web interface of the proposed system such as hits and new visitors, mobile platforms, average time on site and rejection rate.
Resumo:
A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.
Resumo:
A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.
Resumo:
Crossed immunoelectrophoresis (IEC) was used for detection of free and complexed circulating polisaccharide anodic antigen (AgCA) of Schistosoma mansoni in sera of infected hamsters. An attempt was also done to detect AgCA in human sera from patients infected with S. mansoni. The conditions for isolation and detection of complexed AgCA were established. The sensitivity of IEC was increased by incorporation of 2% polyethylene glicol (PEG) to the agarose and by maintaining the system at 4°C during the electrophoretic run. Free AgCA was detected in 12 and the complexed in 30 of the 37 hamsters sera analysed. Correlation between AgCA (free and complexed) and the parasite load was observed. AgCA was not detected, under the experimental conditions used, in human sera from 7 patients in the acute and 23 in the chronic phase of infection.
Resumo:
Recent studies of mobile Web trends show the continued explosion of mobile-friend content. However, the wide number and heterogeneity of mobile devices poses several challenges for Web programmers, who want automatic delivery of context and adaptation of the content to mobile devices. Hence, the device detection phase assumes an important role in this process. In this chapter, the authors compare the most used approaches for mobile device detection. Based on this study, they present an architecture for detecting and delivering uniform m-Learning content to students in a Higher School. The authors focus mainly on the XML device capabilities repository and on the REST API Web Service for dealing with device data. In the former, the authors detail the respective capabilities schema and present a new caching approach. In the latter, they present an extension of the current API for dealing with it. Finally, the authors validate their approach by presenting the overall data and statistics collected through the Google Analytics service, in order to better understand the adherence to the mobile Web interface, its evolution over time, and the main weaknesses.
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.
Resumo:
A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.
Resumo:
Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
In this paper, a damage-detection approach using the Mahalanobis distance with structural forced dynamic response data, in the form of transmissibility, is proposed. Transmissibility, as a damage-sensitive feature, varies in accordance with the damage level. Besides, Mahalanobis distance can distinguish the damaged structural state condition from the undamaged one by condensing the baseline data. For comparison reasons, the Mahalanobis distance results using transmissibility are compared with those using frequency response functions. The experiment results reveal quite a significant capacity for damage detection, and the comparison between the use of transmissibility and frequency response functions shows that, in both cases, the different damage scenarios could be well detected. Copyright (c) 2015 John Wiley & Sons, Ltd.
Resumo:
An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease
Resumo:
Specimens from cervical dysplasias or carcinomas and genital condylomata acuminata were retrospectively analysed by in situ hybridization (ISH) with bioti-nylated DNA probes for human papillomavirus (HPV) types 6, 11, 16 and 18. In the control group no case was positive for HPV DNA. In mild/moderate dysplasias, 4 cases (14%) were positive for HPV 6 or 11 and 2 cases (7%), for HPV 16. In the severe dysplasia/in situ carcinoma group, 9 cases (31%) showed presence of DNA of HPV types 16 or 18. Six invasive carcinomas (20%) were positive for HPV type 16 or 18. Among condylomata acuminata, 22 cases (73%) were positive for HPV types 6 or 11. In all ISH-positive cases only one viral type was detected. No correlation between HPV DNA positivity and histological findings of HPV infection was observed. Although less sensitive than some other molecular biology techniques, in situ hybridization with biotinylated DNA probes proved to be simple and useful for detecting and typing HPV in samples routinely received for histopathological analysis.