974 resultados para monitoring framework


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes how watershed protection is being combined with settlement upgrading and land-use management within an area that serves as one of Greater Sao Paulo's main sources of fresh water. This is being undertaken in the municipality of San to Andre. Unlike previous watershed protection measures, which proved ineffective, it recognizes the need to combine the protection of water-sheds with the improvement of conditions in existing settlements and guiding, rather than prohibiting, further settlement. The paper describes how, the community-based watershed management involves the inhabitants of illegal settlements and other stakeholders in an adaptive planning framework that first seeks consensus on what is to be planned before developing the plan, its implementation and its operation, maintenance and monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper develops a general framework for valuing a wide range of derivative securities. Rather than focusing on the stochastic process of the underlying security and developing an instantaneously-riskless hedge portfolio, we focus on the terminal distribution of the underlying security. This enables the derivative security to be valued as the weighted sum of a number of component pieces. The component pieces are simply the different payoffs that the security generates in different states of the world, and they are weighted by the probability of the particular state of the world occurring. A full set of derivations is provided. To illustrate its use, the valuation framework is applied to plain-vanilla call and put options, as well as a range of derivatives including caps, floors, collars, supershares, and digital options.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent reviews of the desistance literature have advocated studying desistance as a process, yet current empirical methods continue to measure desistance as a discrete state. In this paper, we propose a framework for empirical research that recognizes desistance as a developmental process. This approach focuses on changes in the offending rare rather than on offending itself We describe a statistical model to implement this approach and provide an empirical example. We conclude with several suggestions for future research endeavors that arise from our conceptualization of desistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using NONMEM, the population pharmacokinetics of perhexiline were studied in 88 patients (34 F, 54 M) who were being treated for refractory angina. Their mean +/- SD (range) age was 75 +/- 9.9 years (46-92), and the length of perhexiline treatment was 56 +/- 77 weeks (0.3-416). The sampling time after a dose was 14.1 +/- 21.4 hours (0.5-200), and the perhexiline plasma concentrations were 0.39 +/- 0.32 mg/L (0.03-1.56). A one-compartment model with first-order absorption was fitted to the data using the first-order (FO) approximation. The best model contained 2 subpopulations (obtained via the $MIXTURE subroutine) of 77 subjects (subgroup A) and 11 subjects (subgroup B) that had typical values for clearance (CL/F) of 21.8 L/h and 2.06 L/h, respectively. The volumes of distribution (V/F) were 1470 L and 260 L, respectively, which suggested a reduction in presystemic metabolism in subgroup B. The interindividual variability (CV%) was modeled logarithmically and for CL/F ranged from 69.1% (subgroup A) to 86.3% (subgroup B). The interindividual variability in V/F was 111%. The residual variability unexplained by the population model was 28.2%. These results confirm and extend the existing pharmacokinetic data on perhexiline, especially the bimodal distribution of CL/F manifested via an inherited deficiency in hepatic and extrahepatic CYP2D6 activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes the creation of an objectively acquired reference database to more accurately characterize the incidence and longterm risk of relatively infrequent, but serious, adverse events. Such a database would be maintained longitudinally to provide for ongoing comparison with new rheumatologic drug safety databases collecting the occurrences and treatments of rare events, We propose the establishment of product-specific registries to prospectively follow a cohort of patients with rheumatoid arthritis (RA) who receive newly approved therapies. In addition, a database is required of a much larger cohort of RA patients treated with multiple second line agents of sufficient size to enable case-controlled determinations of the relative incidence of rare but serious events in the treated (registry) versus the larger disease population, The number of patients necessary for agent-specific registries and a larger patient population adequate to supply a matched case-control cohort will depend upon estimates of the detectability of an increased incidence over background. We suggest a system to carry out this proposal that will involve an umbrella organization. responsible for establishment of this large patient cohort, envisioned to be drawn from around the world.