984 resultados para mitral stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear. CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting a parts per thousand yen50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT. Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively. Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: The natriuretic peptides, brain natriuretic peptide (BNP) and its N-terminal prohormone (NT-proBNP), can be used as diagnostic and prognostic markers for aortic stenosis (AS). However, the association between BNP, NT-proBNP, and long-term clinical outcomes in patients with severe AS remains uncertain. Methods: A total of 64 patients with severe AS was prospectively enrolled into the study, and underwent clinical and echocardiographic assessments at baseline. Blood samples were drawn for plasma BNP and NT-proBNP analyses. The primary outcome was death from any cause, through a six-year follow up period. Cox proportional hazards modeling was used to examine the association between natriuretic peptides and long-term mortality, adjusting for important clinical factors. Results: During a mean period of 1,520 681 days, 51 patients (80%) were submitted to aortic valve replacement, and 13 patients (20%) were medically managed without surgical interventions. Mortality rates were 13.7% in the surgical group and 62% in the medically managed group (p <0.001). Patients with higher plasma BNP (>135 pg/ml) and NT-proBNP (>1,150 pg/ml) levels at baseline had a greater risk of long-term mortality (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.1-9.1; HR 4.3, 95% CI 1.4-13.5, respectively). After adjusting for important covariates, both BNP and NT-proBNP remained independently associated with long-term mortality (HR 2.9, 95%CI 1.5-5.7; HR 1.8, 95%CI 1.1-3.1, respectively). Conclusion: In patients with severe AS, plasma BNP and NT-proBNP levels were associated with long-term mortality. The use of these biomarkers to guide treatment might represent an interesting approach that deserves further evaluation. The Journal of Heart Valve Disease 2012;21:331-336

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trata-se de um caso de uma paciente de 30 anos do sexo feminino, com prótese biológica valvar mitral em razão de estenose mitral sintomática e antecedentes de infarto agudo do miocárdio, episódios de convulsões tônico-clônicas generalizadas, alucinações visuais, eventos tromboembólicos cerebrais, apresentando no momento coreia e cardite aguda. Foram diagnosticados na paciente febre reumática em atividade, lúpus eritematoso sistêmico e síndrome do anticorpo antifosfolipídeo. A combinação de três diagnósticos incomuns em um mesmo paciente torna esse caso único, modificando o tratamento e seu prognóstico.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Echocardiography is the standard clinical approach for quantification of the severity of aortic stenosis (AS). A comprehensive examination of its overall reproducibility and the simultaneous estimation of its variance components by multiple operators, readers, probe applications, and beats have not been undertaken. METHOD AND RESULTS Twenty-seven subjects with AS were scanned over 7 months in the echo-department by a median of 3 different operators. From each patient and each operator multiple runs of beats from multiple probe positions were stored for later analysis by multiple readers. The coefficient of variation was 13.3%, 15.9%, 17.6%, and 20.2% for the aortic peak velocity (Vmax), and velocity time integral (VTI), and left ventricular outflow tract (LVOT) Vmax and VTI respectively. The largest individual contributors to the overall variability were the beat-to-beat variability (9.0%, 9.3%, 9.5%, 9.4% respectively) and that of inability of an individual operator to precisely apply the probe to the same position twice (8.3%, 9.4%, 12.9%, 10.7% respectively). The tracing (inter-reader) and reader (inter-reader), and operator (inter-operator) contribution were less important. CONCLUSIONS Reproducibility of measurements in AS is poorer than often reported in the literature. The source of this variability does not appear, as traditionally believed, to result from a lack of training or operator and reader specific factors. Rather the unavoidable beat-to-beat biological variability, and the inherent impossibility of applying the ultrasound probe in exactly the same position each time are the largest contributors. Consequently, guidelines suggesting greater standardisation of procedures and further training for sonographers are unlikely to result in an improvement in precision. Clinicians themselves should be wary of relying on even three-beat averages as their expected coefficient of variance is 10.3% for the peak velocity at the aortic valve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular hypertrophy (LVH) is due to pressure overload or mechanical stretch and is thought to be associated with remodeling of gap-junctions. We investigated whether the expression of connexin 43 (Cx43) is altered in humans in response to different degrees of LVH. The expression of Cx43 was analyzed by quantitative polymerase chain reaction, Western blot analysis and immunohistochemistry on left ventricular biopsies from patients undergoing aortic or mitral valve replacement. Three groups were analyzed: patients with aortic stenosis with severe LVH (n=9) versus only mild LVH (n=7), and patients with LVH caused by mitral regurgitation (n=5). Cx43 mRNA expression and protein expression were similar in the three groups studied. Furthermore, immunohistochemistry revealed no change in Cx43 distribution. We can conclude that when compared with mild LVH or with LVH due to volume overload, severe LVH due to chronic pressure overload is not accompanied by detectable changes of Cx43 expression or spatial distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimal management of patients with symptomatic severe ostial vertebral artery stenosis (OVAS) is currently unclear. We analyzed the long-term outcome of consecutive patients with OVAS who received either medical treatment (MT) or vertebral artery stenting (VAS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a 55-year-old woman is presented, whose clinical signs were initially suggestive of infective endocarditis. Transthoracic echocardiography (TTE) provided the diagnosis of a large left atrial myxoma attached to the anterior mitral leaflet. Perioperative transesophageal echocardiography (TEE) confirmed preoperative findings and assisted the surgical team in the assessment of tumour size, area of attachment, and mobility. Following tumour resection, TEE demonstrated residual moderate mitral valve regurgitation, which resulted in a change of surgical strategy. This report reinforces the importance of intraoperative TEE to facilitate and optimize surgical and anaesthesiological management of patients presenting with non-specific cardiorespiratory symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retrospective case-referent study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess post-procedural and mid-term outcome of patients, in which a second "in-series" CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) was implanted during the same procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiogoniometry (CGM), a spatiotemporal electrocardiologic 5-lead method with automated analysis, may be useful in primary healthcare for detecting coronary artery disease (CAD) at rest. Our aim was to systematically develop a stenosis-specific parameter set for global CAD detection. In 793 consecutively admitted patients with presumed non-acute CAD, CGM data were collected prior to elective coronary angiography and analyzed retrospectively. 658 patients fulfilled the inclusion criteria, 405 had CAD verified by coronary angiography; the 253 patients with normal coronary angiograms served as the non-CAD controls. Study patients--matched for age, BMI, and gender--were angiographically assigned to 8 stenosis-specific CAD categories or to the controls. One CGM parameter possessing significance (P < .05) and the best diagnostic accuracy was matched to one CAD category. The area under the ROC curve was .80 (global CAD versus controls). A set containing 8 stenosis-specific CGM parameters described variability of R vectors and R-T angles, spatial position and potential distribution of R/T vectors, and ST/T segment alterations. Our parameter set systematically combines CAD categories into an algorithm that detects CAD globally. Prospective validation in clinical studies is ongoing.