769 resultados para maxilla osteotomy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a new species of a large eleutherodactyline frog from the mountain rocky meadows (""campos rupestres"") of the Serra do Sincora, Espinha o mountain range, Mucuge municipality, State of Bahia, Brazil. The new species is promptly diagnosed from all the other Brazilian eleutherodactylines by its large size (males SVL 40.3-41.1; females SVL 75.2-79.7mm), broad head (head width 43-49% of SVL), presence of frontoparietal crests, pars fascialis of the maxilla deepened, discs absent on fingers, toes with poorly developed discs, first and second toes ridged, and tarsal fold absent. On the basis of these characters the new species is attributed to the genus Strabomantis up to now restricted to southern part of Central America and northwest part of South America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Excessive mechanical stress due to caudal sloping of the tibial plateau may result In early breakdown of the cranial cruciate ligament (CrCL). Five dogs with CrCL rupture associated with caudal sloping of the proximal tibial plateau are described. All were small dogs, of between three and six years of age, with a mean bodyweight of 9.3 kg, which had acute hindlimb lameness. Radiographic examination revealed cranial displacement of the tibia, with a tibial angle varying from 58 to 60 degrees. All cases were treated with a lateral fabellotibial suture and cranial cuneiform osteotomy of the proximal tibia. All dogs were using the operated limb three days after surgery, with normal gait re-established after a mean period of 10 days. Excessive tibial plateau sloping is not a frequent cause of hindlimb lameness In small animals, although it Is Important to consider it as a predisposing factor for rupture of the CrCL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80° negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80º negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a lack of clinical studies evaluating techniques of functional impression for partially edentulous arches. The aim of this double-blind non-randomized controlled clinical trial was to compare the efficacy of altered cast impression (ACI) and direct functional impression (DFI) techniques. The efficacy was evaluated regarding the number of occlusal units on denture teeth, mucosa integrity at 24-hour follow-up and denture base extension. The sample included 51 patients (female and male) with mean age of 58.96 years treated at Dental Department of UFRN. The patients, exhibiting edentulous maxilla and mandibular Kennedy class I, were divided into two groups (group ACI, n=29; group DFI, n=22). Clinical evaluation was based on the number of occlusal units on natural and/or artificial teeth, mucosa integrity at 24-hour follow-up, and denture base extension. Statistical analysis was conducted using the software SPSS 17.0® (SPSS Inc., Chicago, Illinois). Student T-test was used to reveal association between number of occlusal units and impression technique while chi-square test showed association between mucosa integrity and impression technique. Fischer s exact test was applied for association between denture base extension and impression technique at 95% level of significance. No significant difference was observed between the groups regarding number of occlusal units, mucosa integrity and denture base extension. The altered cast technique did not provide significant improvement in comparison to the direct technique when the number of occlusal units, mucosa integrity and denture base extension

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to clinically and radiographically evaluate acute bone shortening followed by gradual lengthening in the treatment of large segmental tibia defects induced in seven clinically normal dogs. A circular external fixator was assembled with one proximal 5/8-circle ring, one middle ring and one distal ring connected with three rods. Thirty per cent of the tibia and fibula were removed in the middle and distal parts of the diaphyses, between the middle and distal rings. Acute bone shortening with compression of proximal and distal segments was performed. A subperiosteal osteotomy was performed between the half-ring and middle ring. Bone distraction started 7 days after surgery; after lengthening, the apparatus was left in place for 14 weeks for consolidation of regenerated bone. The frame was removed at the end of this period, and the dogs observed for four more weeks. Functional results were considered excellent in two, good in three and fair in the other two dogs. Bone regeneration within the distraction gap was obtained 14 weeks after neutral fixation period. We concluded that acute bone shortening followed by gradual lengthening by Ilizarov method can be used to treat extensive tibial defects in dogs, although it presents limb temporary abnormal limb shape and unequal length as early disadvantages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do estudo foi analisar histologicamente a qualidade, tipo e orientação dos tecidos formados na área de regeneração óssea produzida durante alongamento simultâneo do rádio e da ulna, com fixador externo de Ilizarov, a partir de osteotomia subperiosteal diafisária distal, com dois incrementos diários de 0,5 mm. A montagem foi composta de dois anéis e quatro hastes telescópicas, sendo a distração óssea iniciada no sexto dia de pós-operatório. Utilizaram-se 15 cães, sem raça definida, adultos, com peso corpóreo entre 17 e 30 kg, divididos por sorteio em subgrupos (A, B, C, D e E) compostos por três animais, que foram submetidos a eutanásia após os seguintes procedimentos: A- oito dias de alongamento, B- 15 dias de alongamento, C- 22 dias de alongamento, D- 28 dias de alongamento e oito dias de fase neutra com o fixador, E- 28 dias de alongamento, 60 dias de fase neutra com fixador e 45 dias sem fixador. Os resultados obtidos mostram que o tipo e localização da osteotomia, bem como o ritmo de distração utilizado, não interferiram sobremaneira na regeneração óssea. A reparação óssea foi eficiente, notadamente intramembranosa, contudo nos subgrupos B e C foi observada a presença de cartilagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A boa constrictor was presented with a short oblique compound fracture of the rostral third of the right maxilla. The fracture was reduced and biomaterial was placed around the fracture. A computed tomography scan at 1.5 mo post-surgery showed that the fracture had healed with slight displacement of the bone fragments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.