902 resultados para load curve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the flow-volume curves of 50 patients with complaints of snoring and daytime sleepiness in treatment at the Pneumology Unit of the University Hospital of Brasília. The total group was divided into snorers without obstructive sleep apnea (OSA) (N = 19) and snorers with OSA (N = 31); the patients with OSA were subdivided into two groups according to the apnea/hypopnea index (AHI): AHI<20/h (N = 14) and AHI>20/h (N = 17). The control group (N = 10) consisted of nonsmoking subjects without complaints of snoring, daytime sleepiness or pulmonary diseases. The population studied (control and patients) consisted of males of similar age, height and body mass index (BMI); spirometric data were also similar in the four groups. There was no significative difference in the ratio of forced expiratory and inspiratory flows (FEF50%/FIF50%) in any group: control, 0.89; snorers, 1.11; snorers with OSA (AHI<20/h), 1.42, and snorers with OSA (AHI>20/h), 1.64. The FIF at 50% of vital capacity (FIF50%) of snoring patients with or without OSA was lower than the FIF50% of the control group (P<0.05): snorers 4.30 l/s; snorers with OSA (AHI<20/h) 3.69 l/s; snorers with OSA (AHI>20/h) 3.17 l/s and control group 5.48 l/s. The FIF50% of patients with severe OSA (AHI>20/h) was lower than the FIF50% of snorers without OSA (P<0.05): 3.17 l/s and 4.30 l/s, respectively. We conclude that 1) the FEF50%/FIF50% ratio is not useful for predicting OSA, and 2) FIF50% is decreased in snoring patients with and without OSA, suggesting that these patients have increased upper airway resistance (UAR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the clinical relevance of a semi-quantitative measurement of human cytomegalovirus (HCMV) DNA in renal transplant recipients within the typical clinical context of a developing country where virtually 100% of both receptors and donors are seropositive for this virus, we have undertaken HCMV DNA quantification using a simple, semi-quantitative, limiting dilution polymerase chain reaction (PCR). We evaluated this assay prospectively in 52 renal transplant patients from whom a total of 495 serial blood samples were collected. The samples scored HCMV positive by qualitative PCR had the levels of HCMV DNA determined by end-point dilution-PCR. All patients were HCMV DNA positive during the monitoring period and a diagnosis of symptomatic infection was made for 4 of 52 patients. In symptomatic patients the geometric mean of the highest level of HCMV DNAemia was 152,000 copies per 106 leukocytes, while for the asymptomatic group this value was 12,050. Symptomatic patients showed high, protracted HCMV DNA levels, whereas asymptomatic patients demonstrated intermittent low or moderate levels. Using a cut-off value of 100,000 copies per 106 leukocytes, the limiting dilution assay had sensitivity of 100%, specificity of 92%, a positive predictive value of 43% and a negative predictive value of 100% for HCMV disease. In this patient group, there was universal HCMV infection but relatively infrequent symptomatic HCMV disease. The two patient groups were readily distinguished by monitoring with the limiting dilution assay, an extremely simple technology immediately applicable in any clinical laboratory with PCR capability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the "lactate minimum test" in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were to assess the in vitro-induced anti-hepatitis C virus (HCV) antibody production (IVIAP) in relation to the clinical, biochemical, virologic and histologic variables of patients with HCV infection. The study included 57 patients (60% males) with HCV infection (anti-HCV and HCV-RNA positive). Alanine aminotransferase (ALT) was elevated in 89% of the patients. Mean viral load was 542,241 copies/ml and histology of the liver showed chronic hepatitis in 27/52 (52%) and cirrhosis in 11/52 (21%) patients. IVIAP levels were determined by immunoenzymatic assay at median absorbance of 0.781 at 450 nm. IVIAP was negative in 14% of the patients. When groups with IVIAP levels above and below the median were compared, high IVIAP levels were associated with the male sex, elevated ALT levels and more advanced disease stage. After logistic regression analysis, advanced histologic damage to the liver remained as the only independent variable associated with elevated IVIAP levels. Using a receiver operator characteristic curve, the best cut-off level for IVIAP was established (= 1.540), with 71% sensitivity and 94% specificity for the detection of more advanced disease stages (grades 3 and 4). These findings are consistent with the participation of immunological mechanisms in the genesis of the hepatic lesions induced by HCV and indicate that the IVIAP test may be useful as a noninvasive marker of liver damage either alone or in combination with other markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reverse transcription-polymerase chain reaction (RT-PCR) is the most sensitive method used to evaluate gene expression. Although many advances have been made since quantitative RT-PCR was first described, few reports deal with the mathematical bases of this technique. The aim of the present study was to develop and standardize a competitive PCR method using standard-curves to quantify transcripts of the myogenic regulatory factors MyoD, Myf-5, Myogenin and MRF4 in chicken embryos. Competitor cDNA molecules were constructed for each gene under study using deletion primers, which were designed to maintain the anchorage sites for the primers used to amplify target cDNAs. Standard-curves were prepared by co-amplification of different amounts of target cDNA with a constant amount of competitor. The content of specific mRNAs in embryo cDNAs was determined after PCR with a known amount of competitor and comparison to standard-curves. Transcripts of the housekeeping ß-actin gene were measured to normalize the results. As predicted by the model, most of the standard-curves showed a slope close to 1, while intercepts varied depending on the relative efficiency of competitor amplification. The sensitivity of the RT-PCR method permitted the detection of as few as 60 MyoD/Myf-5 molecules per reaction but approximately 600 molecules of MRF4/Myogenin mRNAS were necessary to produce a measurable signal. A coefficient of variation of 6 to 19% was estimated for the different genes analyzed (6 to 9 repetitions). The competitive RT-PCR assay described here is sensitive, precise and allows quantification of up to 9 transcripts from a single cDNA sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the human T-cell lymphotropic virus type I (HTLV-I) proviral DNA load among asymptomatic HTLV-I-infected carriers and patients with HTLV-I-associated myelopathy/tropical spastic paraparesis (HAM/TSP), real time PCR using TaqMan probes for the pol gene was performed in two million peripheral blood mononuclear cells (PBMC). The albumin gene was the internal genomic control and MT2 cells were used as positive control. The results are reported as copies/10,000 PBMC, and the detection limit was 10 copies. A total of 89 subjects (44 HAM/TSP and 45 healthy HTLV-I-infected carriers) followed up at the Institute of Infectious Diseases "Emilio Ribas" and in the Neurology Division of Hospital of Clínicas were studied. The asymptomatic HTLV-I-infected carriers had a median number of 271 copies (ranging from 5 to 4756 copies), whereas the HAM/TSP cases presented a median of 679 copies (5-5360 copies) in 10,000 PBMC. Thus, HAM/TSP patients presented a significantly higher HTLV-I proviral DNA load than healthy HTLV-I carriers (P = 0.005, one-way Mann-Whitney test). As observed in other persistent infections, proviral DNA load quantification may be an important tool for monotoring HTLV-I-infected subjects. However, long-term follow-up is necessary to validate this assay in the clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salvador (BA, Brazil) is an endemic area for human T-cell lymphotrophic virus type 1 (HTLV-1). The overall prevalence of HTLV-1 infection in the general population has been estimated to be 1.76%. HTLV-1 carriers may develop a variety of diseases such as adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and infective dermatitis associated with HTLV-1 (IDH). IDH is a chronic and severe form of childhood exudative and infective dermatitis involving mainly the scalp, neck and ears. It has recently been observed that 30% of patients with IDH develop juvenile HAM/TSP. The replication of HTLV-1 has been reported to be greater in adult HAM/TSP patients than in asymptomatic HTLV-1 carriers. In the current study, the proviral load of 28 children and adolescents with IDH not associated with HAM/TSP was determined and the results were compared to those obtained in 28 HTLV-1 adult carriers and 28 adult patients with HAM/TSP. The proviral load in IDH patients was similar to that of patients with HAM/TSP and much higher than that found in HTLV-1 carriers. The high levels of proviral load in IDH patients were not associated with age, duration of illness, duration of breast-feeding, or activity status of the skin disease. Since proviral load is associated with neurological disability, these data support the view that IDH patients are at high risk of developing HAM/TSP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During cardiopulmonary exercise testing (CPET), stroke volume can be indirectly assessed by O2 pulse profile. However, for a valid interpretation, the stability of this variable over time should be known. The objective was to analyze the stability of the O2 pulse curve relative to body mass in elite athletes. VO2, heart rate (HR), and relative O2 pulse were compared at every 10% of the running time in two maximal CPETs, from 2005 to 2010, of 49 soccer players. Maximal values of VO2 (63.4 ± 0.9 vs 63.5 ± 0.9 mL O2•kg-1•min-1), HR (190 ± 1 vs188 ± 1 bpm) and relative O2 pulse (32.9 ± 0.6 vs 32.6 ± 0.6 mL O2•beat-1•kg-1) were similar for the two CPETs (P > 0.05), while the final treadmill velocity increased from 18.5 ± 0.9 to 18.9 ± 1.0 km/h (P < 0.01). Relative O2 pulse increased linearly and similarly in both evaluations (r² = 0.64 and 0.63) up to 90% of the running time. Between 90 and 100% of the running time, the values were less stable, with up to 50% of the players showing a tendency to a plateau in the relative O2 pulse. In young healthy men in good to excellent aerobic condition, the morphology of the relative O2 pulse curve is consistent up to close to the peak effort for a CPET repeated within a 1-year period. No increase in relative O2pulse at peak effort could represent a physiologic stroke volume limitation in these athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growing population in cities increases the energy demand and affects the environment by increasing carbon emissions. Information and communications technology solutions which enable energy optimization are needed to address this growing energy demand in cities and to reduce carbon emissions. District heating systems optimize the energy production by reusing waste energy with combined heat and power plants. Forecasting the heat load demand in residential buildings assists in optimizing energy production and consumption in a district heating system. However, the presence of a large number of factors such as weather forecast, district heating operational parameters and user behavioural parameters, make heat load forecasting a challenging task. This thesis proposes a probabilistic machine learning model using a Naive Bayes classifier, to forecast the hourly heat load demand for three residential buildings in the city of Skellefteå, Sweden over a period of winter and spring seasons. The district heating data collected from the sensors equipped at the residential buildings in Skellefteå, is utilized to build the Bayesian network to forecast the heat load demand for horizons of 1, 2, 3, 6 and 24 hours. The proposed model is validated by using four cases to study the influence of various parameters on the heat load forecast by carrying out trace driven analysis in Weka and GeNIe. Results show that current heat load consumption and outdoor temperature forecast are the two parameters with most influence on the heat load forecast. The proposed model achieves average accuracies of 81.23 % and 76.74 % for a forecast horizon of 1 hour in the three buildings for winter and spring seasons respectively. The model also achieves an average accuracy of 77.97 % for three buildings across both seasons for the forecast horizon of 1 hour by utilizing only 10 % of the training data. The results indicate that even a simple model like Naive Bayes classifier can forecast the heat load demand by utilizing less training data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the new age of Internet of Things (IoT), object of everyday such as mobile smart devices start to be equipped with cheap sensors and low energy wireless communication capability. Nowadays mobile smart devices (phones, tablets) have become an ubiquitous device with everyone having access to at least one device. There is an opportunity to build innovative applications and services by exploiting these devices’ untapped rechargeable energy, sensing and processing capabilities. In this thesis, we propose, develop, implement and evaluate LoadIoT a peer-to-peer load balancing scheme that can distribute tasks among plethora of mobile smart devices in the IoT world. We develop and demonstrate an android-based proof of concept load-balancing application. We also present a model of the system which is used to validate the efficiency of the load balancing approach under varying application scenarios. Load balancing concepts can be apply to IoT scenario linked to smart devices. It is able to reduce the traffic send to the Cloud and the energy consumption of the devices. The data acquired from the experimental outcomes enable us to determine the feasibility and cost-effectiveness of a load balanced P2P smart phone-based applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

F/A-18-monitoimihävittäjän ohjaajan tehtävän kognitiiviset vaatimukset ovat korkeat. Kognitiivisen kuormituksen taso vaikuttaa hävittäjäohjaajan suoritustasoon ja subjektiivisiin tun-temuksiin. Yerkesin ja Dodsonin periaatteen mukaisesti erittäin matala tai erittäin korkea kuormituksen taso laskee suoritustasoa. Optimaalinen kuormituksen taso ja suoritustaso saa-vutetaan jossain ääripäiden välillä. Hävittäjäohjaajan kognitiivisen kuormituksen tasoon vaikuttaa lentotehtävän suorittamiseen vaadittava henkinen ponnistelu. Vaadittavan ponnistelun taso riippuu tehtävien vaatimustasosta ja määrästä, tehtäviin käytettävissä olevasta ajasta sekä yksilöllisistä ominaisuuksista. Tutkimuksessa mitattiin kognitiivisen kuormituksen tasoa subjektiivisen arvioinnin menetelmällä NASA-TLX (National Aeronautics and Space Administration - Task Load Index) ja MCH (Modified Cooper-Harper) -mittareilla. Tutkimuksessa selvitettiin mittareiden havaintoarvojen muutosta, sensitiivisyyttä ja yhdenmukaisuutta kognitiivisen kuormituksen tason muuttuessa. Tutkimuksen mittauksiin osallistui 35 Suomen ilmavoimien aktiivisessa palveluksessa olevaa F/A-18-monitoimihävittäjäohjaajaa. Koehenkilöiden lentotuntien keskiarvo F/A-18-monitoimihävittäjällä oli 598 tuntia ja keskihajonta 445 tuntia. Koehenkilöiden tehtävänä oli lentää F/A-18-virtuaalisimulaattorilla 11 ILS (Instrument Landing System) -mittarilähestymistä eri aloitusetäisyyksiltä kiitotien kynnyksestä. Kognitiivisesti kuormitta-van mittarilähestymistehtävän aikana kuormituksen tasoa nostettiin lisätehtävillä ja vähentä-mällä tehtäviin käytettävissä olevaa aikaa. Koehenkilöitä pyydettiin ponnistelemaan mahdollisimman paljon tehtävien suorittamisen aikana hyvän suoritustason ylläpitämiseksi. Tulosten perusteella mittareiden havaintoarvot muuttuivat kognitiivisen kuormituksen tason muuttuessa. Käytettävissä olevan ajan vaikutus kognitiivisen kuormituksen tasoon oli tilastollisesti erittäin merkitsevä. Mittarit olivat sensitiivisiä kognitiivisen kuormituksen tason muutokselle ja antoivat yhdenmukaisia havaintoarvoja.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to determine the glycemic index and glycemic load of tropical fruits and the potential risk for chronic diseases. Nine fruits were investigated: coconut water (for the purpose of this study, coconut water was classified as a “fruit”), guava, tamarind, passion fruit, custard apple, hog plum, cashew, sapodilla, and soursop. The GI and GL were determined according to the Food and Agriculture Organization protocol. The GL was calculated taking into consideration intake recommendation guidelines; 77.8% of the fruits had low GI although significant oscillations were observed in some graphs, which may indicate potential risks of disease. Coconut water and custard apple had a moderate GI, and all fruits had low GL. The fruits evaluated are healthy and can be consumed following the daily recommended amount. However, caution is recommended with fruits causing early glycemic peak and the fruits with moderated GI (coconut water and custard apple).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of ultrasound treatment on carrot juice was investigated through measuring pH, electrical conductivity, viscosity, visual color, total soluble solids, total sugars, total carotenoids, ascorbic acid contents and microbial load. No significant effect (p>0.05) of ultrasound treatment on pH of carrot juice was observed. Electrical conductivity, viscosity and color values gradually increased (p<0.05) with treatment time increase. Total soluble solids, total sugars, total carotenoids and ascorbic acid contents of carrot juice were significantly improved (p<0.05) due to ultrasound treatment. Moreover, significant decrease (p<0.05) in microbial load of sonicated carrot juice was observed. Results from present study suggested that ultrasound treatment could improve quality and safety of carrot juice.