953 resultados para label switching


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ESR spectra of spin probes were used to monitor lipid-protein interactions in native and cholesterol-enriched microsomal membranes. In both systems composite spectra were obtained, one characteristic of bulk bilayer organization and another due to a motionally restricted population, which was ascribed to lipids in a protein microenvironment. Computer spectral subtractions revealed that cholesterol modulates the order/mobility of both populations in opposite ways, i.e., while the lipid bilayer region gives rise to more anisotropic spectra upon cholesterol enrichment, the spectra of the motionally restricted population become indicative of increased mobility and/or decreased order. These events were evidenced by measurement of both effective order parameters and correlation times. The percentages of the motionally restricted component were invariant in native and cholesterol-enriched microsomes. Variable temperature studies also indicated a lack of variation of the percentages of both spectral components, suggesting that the motionally restricted one was not due to protein aggregation. The results correlate well with the effect of cholesterol enrichment on membrane-bound enzyme kinetics and on the behavior of fluorescent probes [Castuma & Brenner (1986) Biochemistry 25, 4733-4738]. Several hypothesis are put forward to explain the molecular mechanism of the cholesterol-induced spectral changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An EPR approach to monitor peptide chain aggregation inside resin beads is introduced. Model low and highly peptide-loaded resins containing an aggregating sequence were labeled with a paramagnetic amino acid derivative and studied with regard to their solvation behavior in different solvent systems. For the first time in the peptide synthesis, EPR spectroscopic has allowed the detection of differentiated levels of peptide chain aggregation as a function of solvent and resin loading. (C) 1997, Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Treatment of deep-vein thrombosis (DVT) with a once-daily regimen of enoxaparin, rather than a continuous infusion of unfractionated heparin (UFH) is more convenient and allows for home care in some patients. This study was designed to compare the efficacy and safety of these two regimens for the treatment of patients with proximal lower limb DVT. Methods: 201 patients with proximal lower limb DVT from 13 centers in Brazil were randomized in an open manner to receive either enoxaparin [1.5 mg/kg subcutaneous (s.c.) OD] or intravenous (i.v.) UFH (adjusted to aPTT 1.5-2.5 times control) for 5-10 days. All patients also received warfarin (INR 2-3) for at least 3 months. The primary efficacy endpoint Was recurrent DVT (confirmed by venography or ultrasonography), and safety endpoints included bleeding and serious adverse events. The rate of pulmonary embolism (PE) was also collected. Hospitalization was at the physician's discretion. Results: Baseline patient characteristics were comparable between groups. The duration of hospital stay was significantly shorter with enoxaparin than with UFH (3 versus 7 days). In addition, 36% of patients receiving enoxaparin did not need to be hospitalized, whereas all of the patients receiving UFH were! hospitalized. The treatment duration was slightly longer with enoxaparin (8 versus 7 days). There was a nonsignificant trend toward a reduction in the rate of recurrent DVT with enoxaparin versus UFH, and similar safety. Conclusions: A once-daily regimen of enoxaparin 1.5 mg/kg subcutaneous is at least as effective and safe as conventional treatment with a continuous intravenous infusion of UFH. However, the once daily enoxaparin regimen is easier to administer (subcutaneous versus intravenous), does not require aPTT monitoring, and leads to both a reduced number of hospital admissions and an average 4-day-shorter hospital stay. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To validate the platform switching concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model. Material & methods: Five minipigs received three implants each with a 0.25mm implant/ abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses. Results: The mean values for peri- implant bone resorption were 1.09 +/- 0.59mm (Control), 0.51 (+/- 0.27 mm, T(0)), 0.50 (+/- 0.46 mm, T(1)) and 1.30 (+/- 0.21 mm, T (+1)), respectively. Statistically significant differences (P< 0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20mm (+/- 0.33), with a connective tissue adaptation compartment of 1.29mm (+/- 0.53) and an epithelial attachment of 1.91 mm (+/- 0.71). T(0), T(1) and T(+1) implants presented with a mean biologic width of 1.97mm (+/- 1.20), 2.70 mm (+/- 1.36) and 2.84mm (+/- 0.90), respectively, with a connective tissue adaptation compartment of 1.21mm (+/- 0.97), 1.21 mm (+/- 0.65) and 1.50 mm (+/- 0.70) and an epithelial attachment of 0.84 mm (+/- 0.93), 1.66 mm (+/- 0.88) and 1.35 mm (+/- 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P = 0.014). However, no other differences between configurations were detected. Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. Levels greater than 3 mu g/mL serum have hitherto been considered to indicate pathology, but there is increasing interest in assessments between 0.1 and 10 mu g/mL, which have been found to correlate with severity of risk for cardiovascular disease. We report herein the generation of both antibody and Affimer based impedance immunoassays for CRP that are substantially more sensitive than clinically utilized immunonephelometry and immunoturbidity assessments. Significant in this study is not only the use of a constrained peptide to detect a clinically important target but also that derived electrochemical impedance assays can be highly sensitive even with probes whose relatively weak (mu M) affinities are not amenable to target detection by surface plasmon resonance (SPR). Key to this finding is acknowledging that receptive surfaces of comparatively low initial steric bulk and charge transfer resistance are especially primed to be highly responsive to target binding in electroanalytical assays of this type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present an offline switching power supply with multiple isolated outputs and unity power factor with the use of only one power processing stage, based on the DC-DC SEPIC (single ended primary inductance converter) modulated by variable hysteresis current control. The principle of operation, the theoretical analysis, the design procedure, an example, and simulation results are presented. A laboratory prototype, rated at 160 W, operating at a maximum switching frequency of 100 kHz, with isolated outputs rated at +5 V/15 A -5 V/1 A, +12 V/6 A and -12 V/1 A, has been built given an input power factor near unity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nucleation and growth model, which is usually applied to switching phenomena, is adapted for explaining surface potential measurements on the P(VDF-TrFE) (polyvinylidene fluoride-trifluoroethylene) copolymer obtained in a constant current corona triode. It is shown that the growth is one-dimensional and that the nucleation rate is unimportant, probably because surface potential measurements take much longer than the switching ones. The surface potential data can therefore be accounted for by a growth model in which the velocity of growth varies exponentially with the electric field. Since hysteresis loops can be obtained from surface potential measurements, it is suggested that similar mechanisms can be used when treating switching and hysteresis phenomena, provided that account is taken of the difference in the time scale of the measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable method of labeling is needed to study dispersal of the braconid parasitoid, Lysiphlebus testaceipes (Cresson), an important biological control of greenbugs, Schizaphis graminum (Rondani), on grain sorghum, Sorghum bicolor (L.) Moench. The feasibility of using aqueous solutions of rubidium chloride (RbCl) applied as a foliar spray or soil drench to label greenbugs and L. testaceipes developing within greenbugs was studied. Laboratory and field studies were conducted to identify the minimal concentration of RbCl to assure labeling of greenbugs and wasps, persistence of Rb throughout the wasp's life span, mobility of Rb to unsprayed sorghum leaves, and feasibility of studying dispersal using a release-recapture technique with Rb-labeled wasps. Both greenbugs and wasps could be labeled using RbCl at concentrations of 2,500-10,000 ppm. Rubidium content in labeled wasps did not significantly vary during the first 7 d after emergence. Greenbugs feeding on unsprayed leaves were labeled up to 4 wk after leaves were sprayed. Rb-labeled wasps were found at the maximum trap distance from the release site (60 m) within 1 d after release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new family of dc-to-dc pulse-width-modulated (PWM) converters is presented. These converters feature soft-commutation at zero-current (ZC) in the active switches. The new ZCS-PWM Boost and new ZCS-PWM Zeta converters, both based on the new ZCS-PWM soft-commutation cell proposed, are used as examples to illustrate the operation of the new family of converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ferroelectric and the dielectric behaviors of binary blends formed by an equi-molar Poly(vinylidene fluoride trifluoroethylene) copolymer [P(VDF-TrFE)] and Poly(methyl methacrylate) [PMMA] were investigated, for several PMMA compositions. For 40 wt.% or more PMMA contents, the blends are completely amorphous. Below this value, they crystallize in the usual Cm2m polar structure of P(VDF-TrFE). The ferroelectric switching characteristics and the dielectric response of the blends demonstrate the formation of dynamically stable ferroelectric domains. Moreover, the blended films are highly transparent in the optical region. Therefore, thin films of these binary blends are good candidates as host materials for nonlinear optical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the problem of establishing stabilizing state-dependent switching laws in DC-DC converters operating at continuous conduction mode (CCM) and comparing their performance indexes. Firstly, the nature of the problem is defined, that is, the study of switched affine systems, which may not share a common equilibrium point. The concept of stability is, therefore, broadened. Then, the central theorem is proposed, from which a family of switching laws can be derived, namely the minimum law and the hold state law. Some of these are proved to stabilize the basic DC-DC converters and then, their performances are compared to another law, from a previous work, by simulation, where a great reduction in overshoot is obtained. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the stress distribution in peri-implant bone by simulating the effect of an implant with microthreads and platform switching on angled abutments through tridimensional finite element analysis. The postulated hypothesis was that the presence of microthreads and platform switching would reduce the stress concentration in the cortical bone. Methods: Four mathematical models of a central incisor supported by an implant (5.0mm×13mm) were created in which the type of thread surface in the neck portion (microthreaded or smooth) and the diameter of the angled abutment connection (5.0 and 4.1mm) were varied. These models included the RM (regular platform and microthreads), the RS (regular platform and smooth neck surface), the SM (platform switching and microthreads), and the SS (platform switching and smooth neck). The analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). An oblique load (100N) was applied to the palatine surface of the central incisor. The bone/implant interface was considered to be perfectly integrated. Values for the maximum (σmax) and minimum (σmin) principal stress, the equivalent von Mises stress (σvM), and the maximum principal elastic strain (e{open}max) for cortical and trabecular bone were obtained. Results: For the cortical bone, the highest σmax (MPa) were observed for the RM (55.1), the RS (51.0), the SM (49.5), and the SS (44.8) models. The highest σvM (MPa) were found for the RM (45.4), the SM (42.1), the RS (38.7), and the SS models (37). The highest values for σmin were found for the RM, SM, RS and SS models. For the trabecular bone, the highest σmax values (MPa) were observed in the RS model (6.55), followed by the RM (6.37), SS (5.6), and SM (5.2) models. Conclusion: The hypothesis that the presence of microthreads and a switching platform would reduce the stress concentration in the cortical bone was partially rejected, mainly because the microthreads increased the stress concentration in cortical bone. Only platform switching reduced the stress in cortical bone. © 2012 Japan Prosthodontic Society.