Resumo:

Townsend's primary and secondary ionization coefficients α/p and γ were determined in nitrogen over a wide range of E/p (100-1000 V cm−1 Torr−1) and p (0·4 to 12 Torr at 0 °C) using the pressure variation technique. This technique, along with the Gosseries method of evaluation of ionization coefficients, seems to be more suitable at higher values of E/p, since the errors in these coefficients could be minimized by a suitable selection of p and d, thus eliminating the non-equilibrium ionization condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple method for evaluating dielectric relaxation parameters ie given whioh can be used for analyeing the arelaxation times of a liquid into two absorptions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An investigation of power frequency (50 Hz) surface partial discharges in dry air, using 21r/3 Rogowski profile electrodes in the low pressure range of 0.067 to 91.333 kPa, shows that for the discharges occurring symmetrically around the electrodes and just outside the uniform field region, the breakdown voltages are 20 to 30% lower than those accounted for by the usual Paschen values. Emphasis, therefore, has been given to modified values of breakdown voltages for any useful calculations. The effect of reduced pressure on inception voltage has been discussed and an attempt has been made to explain the difference between the observed and calculated values on the basis of a pressure-dependent secondary ionization coefficient. It is shown that increasing the insulation thickness in a critical pressure range (0.067 to 0.400 kPa) does not allow any significant increase in the discharge free working stress of the insulation system. At higher pressures (>0.400 kPa) the increase in inception voltage with thickness and pressure follows an equation which is expected to hold for other insulating materials as well.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ratio of diffusion coefficient to mobility (D/¿) for electrons has been measured in SF6-air and freon-nitrogen mixtures for various concentrations of SF6 and freon in the mixtures over the range 140¿ E/p¿ 220 V.cm-1 - torr-1. In SF6-air mixtures, the values of D/¿ were always observed to lie intermediate between the values for the pure gases. However, in freon-nitrogen mixtures, with a small concentration (10 percent) of freon in the mixture, the values of D/¿ are found to lie above the boundaries determined by the pure gases. In this mixture, over the lower E/p range (140 to 190) the electrons appear to lose a large fraction of their energy by the excitation of the complex freon molecules, while at higher E/p values (200 to 240), the excitation and consequent deexcitation of nitrogen molecules and its metastables seem to cause an increased rate of ionization of freon molecules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple triggered vacuum gap has previously been described by the authors in this journal (see ibid., vol.5, 415, 1972). Further studies have resulted in improvement of the performance with regard to sensitivity and consistency of the trigger characteristics and immunity from bridging due to metal particles eroded from the arc. The earlier design suffered from rather frequent bridging of the auxiliary gap and showed rather wide scatter in its trigger characteristics. In the present design thermally stable materials like fused quartz, machinable ceramic 'Supramica 500' (Mycalex Corporation of America), lead titanate, barium titanate (LCC HTD) and silicon carbide have been used to insulate the trigger electrode from the cathode. Consistent triggerings free from bridging, at relatively low voltages of 200-400 V have been obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Firing delays of a simple triggered vacuum gap are reported in this paper. The effects of insulating materials in the auxiliary gap, auxiliary gap current, main gap current and electrode separation on the delay have been investigated. The presence of insulating material in the auxiliary gap having low auxiliary gap resistance appears to exhibit large delay. Delay decreases considerably with increase of current in the auxiliary and the main gaps, but it increases with increase of electrode separation. The scatter in the delay is less than 25 ps and 500 ps with supramica (Mycalex Corporation of America) and silicon carbide respectively at lower values of auxiliary gap current and it becomes negligible for supramica at auxiliary gap currents greater than 6A. This investigation appears to indicate that the simple device can be used as a fast switch.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Townsend's first ionization coefficients have been measured in corssed electric and magnetic fields for values of B/p ranging from 0.013 TESLA. TORR-1 to 0.064 TESLA.TORR-1 and for 103 x 102¿ E/p 331 x 102 V.M-1. TORR-1 in oxygen and for 122 x 102¿ E/pÂ488 x 102 V.M-1.TORR-1 for dry air. The values of effective collision frequencies determined from the equivalent pressure (pe) concept generally increase with E/p at constant B/p and decrease with increasing B/p at constant E/p. Effective collision frequencies determined from measured sparking potentials at high values of E/p increase with decreasing E/pe. The drift velocity and mean energy of electrons in oxygen in crossed electric and magnetic fields have been derived.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The discharge pulse rates at different magnitude levels are often used as criteria for monitoring the partial-discharge aging of insulation systems. Use of suggested corrections for errors in cumulative probability counting leads to better use of available counters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The sparking potentials and swarm coefficients (ionization and attachment coefficients) have been measured in sulphurhexafluoride- air and freon-nitrogen mixtures over the range of 110 ¿ E/p ¿ 240 V cm-1 torr-l and gas pressures varying between 1 and 20 torr, at 20°C. Addition of strongly attaching salphur-hexafluoride and freon gases increased the sparking potentials and the rate of increase of the attachment coefficient with increasing percentage of the strongly attaching gases in the mixtures was much larger than the rate of change of the first ionization coefficient.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The phenomenon of branching at specific angles in streamer breakdown studies is found to be more universal than was ever thought. The angles measured in the breakdown of gases show that the coefficient of field distortion, K, lies in the range from 1 to less than 0.1. The values of K, so obtained agree well with those envisaged in the criterion of the streamer mechanism. It is hoped that branching angles observed in various types of breakdown may, possibly, be explained similarly.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Arc voltage - current characteristics and threshold current densities occuring during the formation of anode spots in triggered vacuum gaps are reported. Single pulses of 1.65 ms arcing time, which correspond to switching surge currents, are used in the study with copper and aluminum anodes. The threshold values are 1.75 times the values reported earlier using the longer, 8 mis, arcing time. They are found to depend upon the duration of arcing time as well as upon electrode material, surface conditions, electrode size and contact separation. Lateral inhomogenity in the electrode geometry appears to reduce the threshold value by promoting early formation of anode spots.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using the concept of energy-dependent effective field intensity, electron transport coefficients in nitrogen have been determined in E times B fields (E = electric field intensity, B = magnetic flux density) by the numerical solution of the Boltzmann transport equation for the energy distribution of electrons. It has been observed that as the value of B/p (p = gas pressure) is increased from zero, the perpendicular drift velocity increased linearly at first, reaches a maximum value, and then decreases with increasing B/p. In general, the electron mean energy is found to be a function of Eavet/p( Eavet = averaged effective electric field intensity) only, but the other transport coefficients, such as transverse drift velocity, perpendicular drift velocity, and the Townsend ionization coefficient, are functions of both E/p and B/p.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Polymeric outdoor insulators are being increasingly used for electrical power transmission and distribution in the recent years. One of the current topics of interest for the power transmission community is the aging of such outdoor polymeric insulators. A few research groups are carrying out aging studies at room temperature with wet period as an integral part of multistress aging cycle as specified by IEC standards. However, aging effect due to dry conditions alone at elevated temperatures and electric stress in the presence of radiation environment has probably not been explored. It is interesting to study and understand the insulator performance under dry conditions where wet periods are either rare or absent and to estimate the extent of aging caused by multiple stresses. This paper deals with the long-term accelerated multistress aging on full-scale 11 kV distribution class composite silicone rubber insulators. In order to assess the long-term synergistic effect of electric stress, temperature and UV radiation on insulators, they are subjected to accelerated aging in a specially designed multistress-aging chamber for 3800 hours. All the stresses are applied at an accelerated level. Using a data acquisition system developed for the work, leakage current has been monitored in LabVIEW environment. Chemical changes due to degradations have been studied using Energy Dispersive X-Ray analysis, Scanning Electron Microscope and Fourier transform Infrared Spectroscopy. Periodically different parameters like low molecular weight (LMW) molecular content, hydrophobicity, leakage current and surface morphology were monitored. The aging study is under progress and only intermediate results are presented in this paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A reliable protection against direct lightning hit is very essential for satellite launch pads. In view of this, suitable protection systems are generally employed. The evaluation of efficacy of the lightning protection schemes among others requires an accurate knowledge of the consequential potential rise at the struck point and the current injected into soil at the earth termination. The present work has made a detailed effort to deduce these quantities for the lightning protection scheme of the Indian satellite launch pad-I. A reduced scale model of the system with a frequency domain approach is employed for the experimental study. For further validation of the experimental approach, numerical simulations using numerical electromagnetic code-2 are also carried out on schemes involving single tower. The study results on the protection system show that the present design is quite safe with regard to top potential rise. It is shown that by connecting ground wires to the tower, its base current and, hence, the soil potential rise can be reduced. An evaluation of an alternate design philosophy involving insulated mast scheme is also made. The potential rise in that design is quantified and the possibility of a flashover to supporting tower is briefly looked into. The supporting tower is shown to have significant induced currents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Transition Radiation Tracker (TRT) of the ATLAS experiment at the LHC is part of the Inner Detector. It is designed as a robust and powerful gaseous detector that provides tracking through individual drift-tubes (straws) as well as particle identification via transition radiation (TR) detection. The straw tubes are operated with Xe-CO2-O2 70/27/3, a gas that combines the advantages of efficient TR absorption, a short electron drift time and minimum ageing effects. The modules of the barrel part of the TRT were built in the United States while the end-cap wheels are assembled at two Russian institutes. Acceptance tests of barrel modules and end-cap wheels are performed at CERN before assembly and integration with the Semiconductor Tracker (SCT) and the Pixel Detector. This thesis first describes simulations the TRT straw tube. The argon-based acceptance gas mixture as well as two xenon-based operating gases are examined for its properties. Drift velocities and Townsend coefficients are computed with the help of the program Magboltz and used to study electron drift and multiplication in the straw using the software Garfield. The inclusion of Penning transfers in the avalanche process leads to remarkable agreements with experimental data. A high level of cleanliness in the TRT s acceptance test gas system is indispensable. To monitor gas purity, a small straw tube detector has been constructed and extensively used to study the ageing behaviour of the straw tube in Ar-CO2. A variety of ageing tests are presented and discussed. Acceptance tests for the TRT survey dimensions, wire tension, gas-tightness, high-voltage stability and gas gain uniformity along each individual straw. The thesis gives details on acceptance criteria and measurement methods in the case of the end-cap wheels. Special focus is put on wire tension and straw straightness. The effect of geometrically deformed straws on gas gain and energy resolution is examined in an experimental setup and compared to simulation studies. An overview of the most important results from the end-cap wheels tested up to this point is presented.