936 resultados para high fix-rate GPS
Resumo:
Background: TILLING (Targeting Induced Local Lesions IN Genomes) is a reverse genetic method that combines chemical mutagenesis with high-throughput genome-wide screening for point mutation detection in genes of interest. However, this mutation discovery approach faces a particular problem which is how to obtain a mutant population with a sufficiently high mutation density. Furthermore, plant mutagenesis protocols require two successive generations (M1, M2) for mutation fixation to occur before the analysis of the genotype can begin. Results: Here, we describe a new TILLING approach for rice based on ethyl methanesulfonate (EMS) mutagenesis of mature seed-derived calli and direct screening of in vitro regenerated plants. A high mutagenesis rate was obtained (i.e. one mutation in every 451 Kb) when plants were screened for two senescence-related genes. Screening was carried out in 2400 individuals from a mutant population of 6912. Seven sense change mutations out of 15 point mutations were identified. Conclusions: This new strategy represents a significant advantage in terms of time-savings (i.e. more than eight months), greenhouse space and work during the generation of mutant plant populations. Furthermore, this effective chemical mutagenesis protocol ensures high mutagenesis rates thereby saving in waste removal costs and the total amount of mutagen needed thanks to the mutagenesis volume reduction.
Resumo:
Tutkielman tarkoituksena on olla kehittämässä UPM-Kymmenen johdon ja keskijohdon rekrytointiprosessia. Tavoitteena on tutkia osaamisniukkuuden aiheuttaman riskin minimoimista, hyvien työntekijöiden palkkaamista ja kuinka työntekijät saadaan pysymään yhtiön palveluksessa. Tutkimusmenetelmä on kvalitatiivinen. Se perustuu muun muassa rekrytointiryhmän kokousten materiaaleihin ja muihin sisäisiin raportteihin sekä haastatteluun. Johdon ja keskijohdon kohdalla mahdollisia rekrytoitavia on vähän, joten heidän pysyvyytensä yrityksen palveluksessa tulee varmistaa. Uuden työntekijän löytäminen on usein vaikeaa ja rekrytointikustannukset ovat suuria. Osaamisniukkuutta voidaan välttää hyvällä henkilöstösuunnittelulla.
Resumo:
OBJECTIVES: Repair of the right ventricular outflow tract (RVOT) in paediatric cardiac surgery remains challenging due to the high reoperation rate. Intimal hyperplasia and consequent arteriosclerosis is one of the most important limitation factors for graft durability. Since local shear stress and pressure are predictive elements for intimal hyperplasia and wall degeneration, we sought to determine in an oversized 12-mm RVOT model, with computed fluid dynamics simulation, the local haemodynamical factors that may explain intimal hyperplasia. This was done with the aim of identifying the optimal degree of oversizing for a 12-mm native RVOT. METHODS: Twenty domestic pigs, with a weight of 24.6 ± 0.89 kg and a native RVOT diameter of 12 ± 1.7 mm, had valve conduits of 12, 16, 18 and 20 mm implanted. Pressure and flow were measured at 75, 100 and 125% of normal flow at RVOT at the pulmonary artery, pulmonary artery bifurcation and at the left and right pulmonary arteries. Three-dimensional computed fluid dynamics (CFD) simulation in all four geometries in all flow modalities was performed. Local shear stress and pressure conditions were investigated. RESULTS: Corresponding to 75, 100 and 125% of steady-state flow, three inlet velocity profiles were obtained, 0.2, 0.29 and 0.36 m/s, respectively. At inflow velocity profiles, low shear stress areas, ranged from 0 to 2 Pa, combined with high-pressure areas ranging from 11.5 to 12.1 mmHg that were found at distal anastomosis, at bifurcation and at the ostia of the left and right pulmonary arteries in all geometries. CONCLUSIONS: In all three oversized geometries, the local reparation of shear stress and pressure in the 16-mm model showed a similar local profile as in the native 12 mm RVOT. According to these findings, we suggest oversizing the natural 12-mm RVOT by not more than 4 mm. The elements responsible for wall degeneration and intimal hyperplasia remain very similar to the conditions present in native RVOT.
Resumo:
Aims: The aims were to create clinically feasible reference intervals for thyroidstimulating hormone (TSH) and free thyroxine (FT4) and to analyze associations between thyroid function and self-rated health, neuropsychiatric symptoms, depression and dementia in the elderly. The second aim was also to establish reference intervals for sex hormones and to analyze associations between sex hormone levels and self-rated health, symptoms, depression and dementia in elderly men. Subjects and methods: The study population comprised 1252 subjects aged 65 years or over, living in the municipality of Lieto, south-western Finland. Self-rated health, life satisfaction, symptoms, depression, and dementia were assessed with specific questions, clinical examination and tools such as the Zung Self-report Depression Scale and the Mini-Mental State Examination. Independent variables were dichotomized, and associations of these variables with TSH, FT4 or sex hormone levels were assessed. Levels of TSH and FT4 in thyroid disease–free women and women treated with thyroxine were also compared. Results: Elevated concentrations of thyroid peroxidase antibodies (TPOAb) or thyroglobulin antibodies (TgAb) were found to have a marked effect on the upper reference limit for TSH among women, who were thyroid antibody positive more higher than suggested in several recent guidelines. After age adjustment, there were no associations between TSH levels and self-rated health, life satisfaction, or most neuropsychiatric symptoms in the thyroid disease-free population. Although women with thyroxine treatment for primary hypothyroidism had far higher TSH levels than thyroid disease-free women, there were no differences between thyroid-disease free women and women with stable thyroxine treatment regarding self-rated health, life satisfaction or symptoms. Age had a significant positive association with luteinizing hormone (LH), follicle 2 practice, one range in men aged 65 years or over can be used for T, E2 and FSH measured with the AutoDelfia method, but two separate reference intervals should be used for fT, LH and SHBG. After adjustment for age, higher levels of T and fT were associated with better self-rated health (SRH) in the reference population. After adjustment for age and body mass index (BMI), there were no associations between sex hormone concentrations and self-rated health, life satisfaction or most symptoms in concentration. Conclusion: Age-specific reference intervals were derived for thyroid function and sex hormones based on comprehensive data from a community-dwelling population with a high participation rate. The results do not support the need to decrease the upper reference limit for TSH or to lower the optimal TSH target in levothyroxine treatment in older adults, as recommended in recent guidelines. Older age or being overweight symptoms among elderly men. The associations of single symptoms with T levels were inconsistent among elderly men, although the association of low T level with diagnosed depression might be clinically significant.
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
The prevalence of abdominal aortic aneurysm (AAA) in general population is 4-9% with a high mortality rate when ruptured. Therefore, screening programs were developed in many countries to detect small and large AAA in selected patients. Indeed, prevalence of AAA increases in patients over 65 years old with cigarette smoking history. This paper reviews recent literature related to AAA screening focusing on epidemiology, screening tests and evidence based medicine to highlight not only advantages but also disadvantages of screening programs among population.
Resumo:
Dado los diferentes métodos terapéuticos para el cáncer de labio, el objetivo del presente estudio es valorar los resultados obtenidos en un grupo prospectivo de 28 pacientes afectos de carcinoma de labio tratados mediante moldes externos de braquiterapia de alta tasa de dosis. Tanto por la remisión completa que ocurrió en todos los casos, la buena tolerancia a la terapia, la ausencia de complicaciones y de recurrencias, la facilidad de empleo de los moldes, la precisión en el posicionamiento de la fuente en la repetición diaria del tratamiento y la seguridad que ofrece en cuanto a radioprotección, concluímos que esta terapéutica probablemente se convierta en la de uso habitual en los próximos años.
Resumo:
Intravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.
Resumo:
Ultrasound image reconstruction from the echoes received by an ultrasound probe after the transmission of diverging waves is an active area of research because of its capacity to insonify at ultra-high frame rate with large regions of interest using small phased arrays as the ones used in echocardiography. Current state-of-the-art techniques are based on the emission of diverging waves and the use of delay and sum strategies applied on the received signals to reconstruct the desired image (DW/DAS). Recently, we have introduced the concept of Ultrasound Fourier Slice Imaging (UFSI) theory for the reconstruction of ultrafast imaging for linear acquisition. In this study, we extend this theory to sectorial acquisition thanks to the introduction of an explicit and invertible spatial transform. Starting from a diverging wave, we show that the direct use of UFSI theory along with the application of the proposed spatial transform allows reconstructing the insonified medium in the conventional Cartesian space. Simulations and experiments reveal the capacity of this new approach in obtaining competitive quality of ultrafast imaging when compared with the current reference method.
Resumo:
Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.
Resumo:
It is widely recognized that pharmacokinetic optimization needs to be addressed early in drug discovery to reduce the high failure rate in bringing drugs to market. Poor absorption, too short duration of action due to high elimination rate, or the presence of active metabolites are examples of properties that can potentially lead to unsuccessful clinical programmes. Here I describe a brief overview of advantages and molecular strategies for improving metabolic and pharmacokinetic properties applied to the discovery of fluconazol, beta-blockers, ritonavir and ezetimibe and to the development of the prodrugs enalapril and bambuterol.
Resumo:
Sensor-based robot control allows manipulation in dynamic environments with uncertainties. Vision is a versatile low-cost sensory modality, but low sample rate, high sensor delay and uncertain measurements limit its usability, especially in strongly dynamic environments. Force is a complementary sensory modality allowing accurate measurements of local object shape when a tooltip is in contact with the object. In multimodal sensor fusion, several sensors measuring different modalities are combined to give a more accurate estimate of the environment. As force and vision are fundamentally different sensory modalities not sharing a common representation, combining the information from these sensors is not straightforward. In this thesis, methods for fusing proprioception, force and vision together are proposed. Making assumptions of object shape and modeling the uncertainties of the sensors, the measurements can be fused together in an extended Kalman filter. The fusion of force and visual measurements makes it possible to estimate the pose of a moving target with an end-effector mounted moving camera at high rate and accuracy. The proposed approach takes the latency of the vision system into account explicitly, to provide high sample rate estimates. The estimates also allow a smooth transition from vision-based motion control to force control. The velocity of the end-effector can be controlled by estimating the distance to the target by vision and determining the velocity profile giving rapid approach and minimal force overshoot. Experiments with a 5-degree-of-freedom parallel hydraulic manipulator and a 6-degree-of-freedom serial manipulator show that integration of several sensor modalities can increase the accuracy of the measurements significantly.
Resumo:
The purpose of the thesis is to examine the added value of combining value and momentum indicators in the Swiss stock exchange. Value indicators employed are P/E, EV/EBITDA, P/CF, P/B ja P/S. Momentum indicators examined are 52-week high, acceleration rate, 12-month past return and 6-month past return. The thesis examines whether the composite value measures based on the above mentioned ratios can add value and whether the inclusion of momentum can further improve the risk return profile of the value portfolios. The data is gathered from the Swiss equity market during the sample period from May 2001 to May 2011. Previous studies have shown that composite value measures can somewhat add value to the value portfolio strategy. Similarly, recent academic literature have found evidence that momentum works well as a timing indicator for time to entry to value stocks. This study indicates that the added value of composite value measures exists. It also shows that momentum combined to acceleration rate can significantly improve the risk adjusted performance of value-only portfolios.
Resumo:
BACKGROUND: A new procedure for the treatment of esophageal fistula, mainly associated to the ebb esophagojejunal in patients submitted to the total gastrectomy and reconstruction with loop jejunal Rouxen-Y anastomosis is present. METHODS: The method is based in the use of "probe standard enteral prolongated with drain to laminate adapted in extremity", which results in advanced positioning inside the jejunum, making the administration of enteral nutrition possible and impeding ebb esophagojejunal. RESULTS: The authors discuss the theoretical advantages of the procedure and they suggest that the treatment of esofagic fistula with probe prolonged enteral would be suitable in the treatment of the fistula esophagojejunal by preventing the ebb esophagojejunal, which would result in smaller period of duration of the fistula esophagojejunal and it would prevent the high mortality rate. CONCLUSIONS: Preliminary studies demonstrated that this is a technically easy, low cost procedure through the endoscopic use. A prospective evaluation for morbility and mortality related to the method is needed.