936 resultados para groundwater sampling
Resumo:
Imputation is commonly used to compensate for item non-response in sample surveys. If we treat the imputed values as if they are true values, and then compute the variance estimates by using standard methods, such as the jackknife, we can seriously underestimate the true variances. We propose a modified jackknife variance estimator which is defined for any without-replacement unequal probability sampling design in the presence of imputation and non-negligible sampling fraction. Mean, ratio and random-imputation methods will be considered. The practical advantage of the method proposed is its breadth of applicability.
Resumo:
Phylogenetic methods hold great promise for the reconstruction of the transition from precursor to modern flora and the identification of underlying factors which drive the process. The phylogenetic methods presently used to address the question of the origin of the Cape flora of South Africa are considered here. The sampling requirements of each of these methods, which include dating of diversifications using calibrated molecular trees, sister pair comparisons, lineage through time plots and biogeographical optimizations are reviewed. Sampling of genes, genomes and species are considered. Although increased higher-level studies and increased sampling are required for robust interpretation, it is clear that much progress is already made. It is argued that despite the remarkable richness of the flora, the Cape flora is a valuable model system to demonstrate the utility of phylogenetic methods in determining the history of a modern flora.
Resumo:
Groundwater is an important resource in the UK, with 45% of public water supplies in the Thames Water region derived from subterranean sources. In urban areas, groundwater has been affected by onthropogenic activities over 0 long period of time and from a multitude of sources, At present, groundwater quality is assessed using a range of chemical species to determine the extent of contamination. However, analysing a complex mixture of chemicals is time-consuming and expensive, whereas the use of an ecotoxicity test provides information on (a) the degree of pollution present in the groundwater and (b) the potential effect of that pollution. Microtox (TM), Eclox (TM) and Daphnia magna microtests were used in conjunction with standard chemical protocols to assess the contamination of groundwaters from sites throughout the London Borough of Hounslow and nearby Heathrow Airport. Because of their precision, range of responses and ease of use, Daphnia magna and Microfox (TM) tests are the bioassays that appear to be most effective for assessing groundwater toxicity However, neither test is ideal because it is also essential to monitor water hardness. Eclox (TM) does not appear to be suitable for use in groundwater-quality assessment in this area, because it is adversely affected by high total dissolved solids and electrical conductivity.
Resumo:
A novel biomarker was developed in Daphnia magna to detect organic pollution in groundwater. The haem peroxidase assay, which is an indirect means of measuring oxidase activity, was particularly sensitive to kerosene contamination. Exposure to sub-lethal concentrations of kerosene-contaminated groundwater resulted in a haem peroxidase activity increase by dose with a two-fold activity peak at 25%. Reproduction in D. magna remained unimpaired when exposed to concentrations below 25% for 21 days, and a decline in fecundity was only observed at concentrations above the peak in enzyme activity. The measurement of haem peroxidase activity in D. magna detected sublethal effects of kerosene in just 24 h, whilst offering information on the health status of the organisms. The biomarker may be useful in determining concentrations above which detrimental effects would occur from long-term exposure for fuel hydrocarbons. Moreover, this novel assay detects exposure to chemicals in samples that would normally be classified as non-toxic by acute toxicity tests.
Resumo:
Multivariate statistical methods were used to investigate file Causes of toxicity and controls on groundwater chemistry from 274 boreholes in an Urban area (London) of the United Kingdom. The groundwater was alkaline to neutral, and chemistry was dominated by calcium, sodium, and Sulfate. Contaminants included fuels, solvents, and organic compounds derived from landfill material. The presence of organic material in the aquifer caused decreases in dissolved oxygen, sulfate and nitrate concentrations. and increases in ferrous iron and ammoniacal nitrogen concentrations. Pearson correlations between toxicity results and the concentration of individual analytes indicated that concentrations of ammoinacal nitrogen, dissolved oxygen, ferrous iron, and hydrocarbons were important where present. However, principal component and regression analysis suggested no significant correlation between toxicity and chemistry over the whole area. Multidimensional Scaling was used to investigate differences in sites caused by historical use, landfill gas status, or position within the sample area. Significant differences were observed between sites with different historical land use and those with different gas status. Examination of the principal component matrix revealed that these differences are related to changes in the importance of reduced chemical species.
Resumo:
Part IIA of the Environmental Protection Act 1990 requires environmental regulators to assess the risk of contaminants leaching from soils into groundwater (DETR, 1999). This newly introduced legislation assumes a link between soil and groundwater chemistry, in which rainwater leaches contaminants from soil into the saturated zone. As the toxicity of both groundwater and overlying soils is dependent upon the chemicals present, their partitioning and their bioavailability, similar patterns of soil, leachates and groundwater toxicity should be observed at contaminated sites. Soil and groundwater samples were collected from different contaminated land sites in an urban area, and used to determine relationships between soil chemistry and toxicity, mobility of contaminants, and groundwater chemistry and toxicity. Soils were leached using water to mimic rainfall, and both the soils and leachates tested using bioassays. Soil bioassays were carried out using Eisenia fetida, whilst groundwater and leachates were tested using the Microtox(TM) test system and Daphnia magna 48 h acute tests. Analysis of the bioassay responses demonstrated that a number of the samples were toxic to test organisms, however, there were no significant statistical relationships between soil, groundwater and leachate toxicity. Nor were there significant correlations between soil, leachates and groundwater chemistry.
Resumo:
The sampling of certain solid angle is a fundamental operation in realistic image synthesis, where the rendering equation describing the light propagation in closed domains is solved. Monte Carlo methods for solving the rendering equation use sampling of the solid angle subtended by unit hemisphere or unit sphere in order to perform the numerical integration of the rendering equation. In this work we consider the problem for generation of uniformly distributed random samples over hemisphere and sphere. Our aim is to construct and study the parallel sampling scheme for hemisphere and sphere. First we apply the symmetry property for partitioning of hemisphere and sphere. The domain of solid angle subtended by a hemisphere is divided into a number of equal sub-domains. Each sub-domain represents solid angle subtended by orthogonal spherical triangle with fixed vertices and computable parameters. Then we introduce two new algorithms for sampling of orthogonal spherical triangles. Both algorithms are based on a transformation of the unit square. Similarly to the Arvo's algorithm for sampling of arbitrary spherical triangle the suggested algorithms accommodate the stratified sampling. We derive the necessary transformations for the algorithms. The first sampling algorithm generates a sample by mapping of the unit square onto orthogonal spherical triangle. The second algorithm directly compute the unit radius vector of a sampling point inside to the orthogonal spherical triangle. The sampling of total hemisphere and sphere is performed in parallel for all sub-domains simultaneously by using the symmetry property of partitioning. The applicability of the corresponding parallel sampling scheme for Monte Carlo and Quasi-D/lonte Carlo solving of rendering equation is discussed.
Resumo:
High spatial resolution vertical profiles of pore-water chemistry have been obtained for a peatland using diffusive equilibrium in thin films (DET) gel probes. Comparison of DET pore-water data with more traditional depth-specific sampling shows good agreement and the DET profiling method is less invasive and less likely to induce mixing of pore-waters. Chloride mass balances as water tables fell in the early summer indicate that evaporative concentration dominates and there is negligible lateral flow in the peat. Lack of lateral flow allows element budgets for the same site at different times to be compared. The high spatial resolution of sampling also enables gradients to be observed that permit calculations of vertical fluxes. Sulfate concentrations fall at two sites with net rates of 1.5 and 5.0nmol cm− 3 day− 1, likely due to a dominance of bacterial sulfate reduction, while a third site showed a net gain in sulfate due to oxidation of sulfur over the study period at an average rate of 3.4nmol cm− 3 day− 1. Behaviour of iron is closely coupled to that of sulfur; there is net removal of iron at the two sites where sulfate reduction dominates and addition of iron where oxidation dominates. The profiles demonstrate that, in addition to strong vertical redox related chemical changes, there is significant spatial heterogeneity. Whilst overall there is evidence for net reduction of sulfate within the peatland pore-waters, this can be reversed, at least temporarily, during periods of drought when sulfide oxidation with resulting acid production predominates.
Resumo:
O grupo das mulheres trabalhadoras do sexo (MTS) é reconhecido como uma populaçãode maior risco à infecção pelo HIV, tanto pela prevalência elevada, como por suavulnerabilidade social como pelos fatores relacionados à própria atividade profissional. Porém, arealização de estudos nos subgrupos de maior risco ao HIV mediante estratégias convencionaisde amostragem é, em geral, problemática por essas populações possuírem pequena magnitudeem termos populacionais e por estarem vinculados a comportamentos estigmatizados ouatividades ilegais. Em 1997, foi proposto um método de amostragem probabilística parapopulações de difícil acesso denominado Respondent-Driven Sampling (RDS). O método éconsiderado como uma variante da amostragem em cadeia e possibilita a estimação estatísticados parâmetros de interesse. Na literatura internacional, para análise de dados coletados porRDS, muitos autores têm utilizado técnicas estatísticas multivariadas tradicionais, sem levar emconta a estrutura de dependência das observações, presente nos dados coletados por RDS.A presente tese tem por objetivo contribuir para suprir informações sobre as práticas derisco relacionadas ao HIV entre as mulheres trabalhadoras do sexo (MTS) com odesenvolvimento de método estatístico para análise de dados coletados com o método deamostragem RDS. Com tal finalidade, foram utilizadas as informações coletadas na PesquisaCorrente da Saúde realizada em dez cidades brasileiras, com 2.523 MTS recrutadas por RDS,entre os anos de 2008 e 2009. O questionário foi autopreenchido e incluiu módulos sobrecaracterísticas da atividade profissional, práticas sexuais, uso de drogas, testes periódicos deHIV, e acesso aos serviços de saúde.Primeiramente, foram descritos alguns pressupostos do RDS e todas as etapas deimplantação da pesquisa. Em seguida, foram propostos métodos de análise multivariada, considerando o RDS como um desenho complexo de amostragem.
Resumo:
Passive samplers have been predominantly used to monitor environmental conditions in single volumes. However, measurements using a calibrated passive sampler- Solid Phase Microextraction (SPME) fibre, in three houses with cold pitched roof, successfully demonstrated the potential of the SPME fibre as a device for monitoring air movement in two volumes. The roofs monitored were pitched at 15° - 30° with insulation thickness varying between 200-300 mm on the ceiling. For effective analysis, two constant sources of volatile organic compounds were diffused steadily in the house. Emission rates and air movement from the house to the roof was predicted using developed algorithms. The airflow rates which were calibrated against conventional tracer gas techniques were introduced into a HAM software package to predict the effects of air movement on other varying parameters. On average it was shown from the in situ measurements that about 20-30% of air entering the three houses left through gaps and cracks in the ceiling into the roof. Although these field measurements focus on the airflows, it is associated with energy benefits such that; if these flows are reduced then significantly energy losses would also be reduced (as modelled) consequently improving the energy efficiency of the house. Other results illustrated that condensation formation risks were dependent on the airtightness of the building envelopes including configurations of their roof constructions.