587 resultados para endovascular treament
Resumo:
OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.
Resumo:
A particular event concerning a Swan-Ganz catheter complication is reported. A 41-year-old woman was admitted at the emergency room of our hospital with massive gastrointestinal bleeding. A total gastrectomy was performed. During the postoperative period in the intensive care unit , the patient maintained hemodynamic instability. Invasive hemodynamic monitoring with a pulmonary artery catheter was then indicated. During the maneuvers to insert the catheter, a true knot formation was identified at the level of the superior vena cava. Several maneuvers by radiological endovascular invasive techniques allowed removal of the catheter. The authors describe the details of this procedure and provide comments regarding the various techniques that were employed in overcoming this event. A comprehensive review of evidence regarding the benefits and risks of pulmonary artery catheterization was performed. The consensus statement regarding the indications, utilization, and management of the pulmonary artery catheterization that were issued by a consensus conference held in 1996 are also discussed in detail.
Resumo:
PURPOSE: Inspite of the long experience with the treatment of intermittent claudication, little is known about the natural history of stenotic lesions in the iliac segment. With the advent of endovascular treatment, this knowledge has become important. METHODS: Fifty-two stenosis, diagnosed using arteriography, in 38 claudicant patients were analyzed. After a minimum time interval of 6 months, a magnetic resonance angiography was performed to determine whether there was arterial occlusion. The primary factors that could influence the progression of a stenosis were analyzed, such as risk factors (smoking, hypertension, diabetes, sex, and age), compliance with clinical treatment, initial degree of stenosis, site of the stenosis, and length of follow-up. RESULTS: The average length of follow-up was 39 months. From the 52 lesions analyzed, 13 (25%) evolved to occlusion. When occlusion occurred, there was clinical deterioration in 63.2% of cases. This association was statistically significant (P = .002). There was no statistically significant association of the progression of the lesion with the degree or site of stenosis, compliance with treatment, or length of follow-up. Patients who evolved to occlusion were younger (P = .02). The logistic regression model showed that the determinant factors for clinical deterioration were arterial occlusion and noncompliance with clinical treatment. CONCLUSIONS: The progression of a stenosis to occlusion, which occurred in 25% of the cases, caused clinical deterioration. Clinical treatment was important, but it did not forestall the arterial occlusion. Prevention of occlusion could be achieved by early endovascular intervention or with the development of drugs that might stabilize the atherosclerotic plaque.
Resumo:
A Tomografia de Coerência Ótica (TCO) é uma nova tecnologia de imagem baseada em interferometria de baixa coerência que utiliza a dispersão de luz quase-infravermelha como uma fonte de sinal para fornecer imagens transversais vasculares com definição muito superior à de qualquer outra modalidade disponível. Com uma resolução espacial de até 10μm, a TCO fornece uma resolução 20 vezes maior do que o ultrassom intravascular (USIV), a modalidade atualmente mais utilizada para obter imagens intra-coronárias. A TCO tem uma capacidade de fornecer um entendimento das várias fases da doença aterosclerótica e a resposta vascular ao tratamento. Estudos tem mostrado a capacidade da TCO em detectar estruturas arteriais e ajudar na determinação de diferentes constituintes histológicos. Sua capacidade de distinguir diferentes graus de alterações ateroscleróticas e os vários tipos de placas, quando comparada à histologia, tem sido recentemente demonstrada com correlações inter e intra-observador aceitáveis para esses achados. A TCO fornece uma resolução endovascular excepcional em tempo real in vivo, que tem sido explorada para avaliar as estruturas vasculares e a resposta ao uso do equipamento. Embora a profundidade permaneça uma limitação para a caracterização de placa além de 2 mm através da TCO, uma resolução próxima à histológica pode ser obtida dentro do primeiro milímetro da parede do vaso, permitindo uma avaliação extraordinária das características e espessura da capa fibrosa. Além disso, a avaliação da cobertura de neoíntima, padrões de tecido para-haste e aposição de stent podem agora ser escrutinizados para hastes individuais na escala de mícrons, a assim chamada análise em nível de haste. A TCO levou a imagem intravascular ao nível de mícron na análise vascular in vivo e espera-se que breve se torne uma ferramenta valiosa e indispensável para cardiologistas em aplicações clínicas e de pesquisa.
Resumo:
Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.
Resumo:
Dans la majorité des cas, les diarrhées aiguës sont bénignes et d'évolution spontanément favorable. Il faut cependant savoir reconnaître les situations pouvant mener à des complications, en l'occurrence identifier les diarrhées invasives, inflammatoires, caractérisées par la présence de fièvre, de douleurs abdominales, de ténesmes, de mucus et, ou de sang dans les selles. Celles-ci sont à distinguer des diarrhées sécrétoires, non invasives, non inflammatoires, sans fièvre, généralement aqueuses et volumineuses. En cas de doute diagnostique, l'identification de leucocytes par microscopie ou test à la lactoferrine dans les selles permet d'évoquer une gastroentérite invasive. Les indications à une antibiothérapie empirique dans l'attente du résultat de la coproculture sont la présence d'un syndrome dysentérique (T > 38°C, > 6 selles/24 heures, douleurs abdominales, diarrhées mucopurulentes), l'âge avancé, des comorbidités significatives, une immunosuppression et la présence d'une prothèse endovasculaire. In the majority of the cases, an acute diarrhea is mild and of spontaneously favorable evolution. It is however necessary to know how to recognize the situations being able to lead to complications, in particular to identify the invasive, inflammatory diarrheas, characterized by the presence of fever, abdominal pains, mucus and\or blood. The identification of leukocytes by microscopy or lactoferrine test is helpful. Empiric quinolones treatment is recommended in the presence of dysenteric syndrome (T > 38 degrees C, > 6 stods/24 h 00, abdominal pain muco-purulent diarrhea), advanced age, significant comorbidities, immunosuppression or presence of an endovascular prothesis
Resumo:
BACKGROUND AND PURPOSE: Surgical clipping of unruptured intracranial aneurysms (UIAs) has recently been challenged by the emergence of endovascular treatment. We performed an updated systematic review and meta-analysis on the surgical treatment of UIAs, in an attempt to determine the aneurysm occlusion rates and safety of surgery in the modern era. METHODS: A detailed protocol was developed prior to conducting the review according to the Cochrane Collaboration guidelines. Electronic databases spanning January 1990-April 2011 were searched, complemented by hand searching. Heterogeneity was assessed using I(2), and publication bias with funnel plots. Surgical mortality and morbidity were analysed with weighted random effect models. RESULTS: 60 studies with 9845 patients harbouring 10 845 aneurysms were included. Mortality occurred in 157 patients (1.7%; 99% CI 0.9% to 3.0%; I(2)=82%). Unfavourable outcomes, including death, occurred in 692 patients (6.7%; 99% CI 4.9% to 9.0%; I(2)=85%). Morbidity rates were significantly greater in higher quality studies, and with large or posterior circulation aneurysms. Reported morbidity rates decreased over time. Studies were generally of poor quality; funnel plots showed heterogeneous results and publication bias, and data on aneurysm occlusion rates were scant. CONCLUSIONS: In studies published between 1990 and 2011, clipping of UIAs was associated with 1.7% mortality and 6.7% overall morbidity. The reputed durability of clipping has not been rigorously documented. Due to the quality of the included studies, the available literature cannot properly guide clinical decisions.
Resumo:
Introduction. Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. Aim. To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. Materials and methods. A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. Results. Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. Conclusions. Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation.
Resumo:
SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.
Resumo:
Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.
Resumo:
A mycotic pseudoaneurysm of the popliteal artery is usually a consequence of septic embolization and often a result of bacterial endocarditis. Conventional treatment is surgical and avoids the placement of foreign material in infected sites. Here we report our treatment of a 59-year-old man who presented with a rupture of a mycotic pseudoaneurysm of the popliteal artery due to septic embolism from sternoclavicular infectious arthritis. Radiological investigations are included. This is the first documented case of septic arthritis complicated by a rupture of a mycotic popliteal false aneurysm and treated using an endovascular procedure. Combining endovascular stent grafts with evacuation of the joint abscess and antibiotic therapy can offer a safe alternative for frail and unstable patients.
Resumo:
Critical limb ischemia is a major public health problem in our western countries due to the epidemia of (diabesity). The outcome of patients suffering from critical limb ischemia reains poor with an amputation free survival rate at one year of about 50%. The treatment should be multidiciplinary and done in emergency in specialized centers to ensure the limb salvage: this management should be centered aroud 3 axis: the screening of the cardiovascular risk factors, the best medical treatment and the invasive approaches. Due to multiple endovascular technical innovations, more frail patients with com plex diseases can be treated with good results. Therefore, the endovascular treatment is essential in the management of such patients by vascular surgeons.
Resumo:
Because Staphylococcus aureus strains contain multiple virulence factors, studying their pathogenic role by single-gene inactivation generated equivocal results. To circumvent this problem, we have expressed specific S. aureus genes in the less virulent organism Streptococcus gordonii and tested the recombinants for a gain of function both in vitro and in vivo. Clumping factor A (ClfA) and coagulase were investigated. Both gene products were expressed functionally and with similar kinetics during growth by streptococci and staphylococci. ClfA-positive S. gordonii was more adherent to platelet-fibrin clots mimicking cardiac vegetations in vitro and more infective in rats with experimental endocarditis (P < 0.05). Moreover, deleting clfA from clfA-positive streptococcal transformants restored both the low in vitro adherence and the low in vivo infectivity of the parent. Coagulase-positive transformants, on the other hand, were neither more adherent nor more infective than the parent. Furthermore, coagulase did not increase the pathogenicity of clfA-positive streptococci when both clfA and coa genes were simultaneously expressed in an artificial minioperon in streptococci. These results definitively attribute a role for ClfA, but not coagulase, in S. aureus endovascular infections. This gain-of-function strategy might help solve the role of individual factors in the complex the S. aureus-host relationship.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
OBJECTIVES: The purpose of this study was to assess short- and mid-term results of in-situ revascularisation (ISR) using silver-coated Dacron prostheses and bowel repair for management of secondary aorto-enteric fistulae (SAEF). DESIGN: Single-centre retrospective chart review. MATERIAL AND METHODS: This study includes all the patients treated by ISR using silver-coated Dacron for SAEF between 2006 and 2010. Primary end points were mortality and survival rates. Secondary end points were reinfection-free survival and secondary patency rates. RESULTS: Eighteen male patients with SAEF with a median age of 64 years were operated by ISR using silver-coated Dacron during the study period without operative death. The 30-day mortality was 22% and the in-hospital mortality rate was 39%. Indeed, during hospitalisation, a duodenal leak was observed in four patients including three who died. Four others patients died due to multi-system organ failure. Median follow-up was 16 months (range 1-66). The survival rate at 12 months was 55%. One duodenal leak was observed leading to death. The reinfection-free survival and the secondary patency rates at 12 months were 60% and 89%, respectively. CONCLUSION: In-situ revascularisation with silver-coated Dacron provides acceptable results in terms of mortality. This treatment may be useful for simple vascular reconstruction and allow greater attention to bowel repair that is a determinant in short- and mid-term survival.