871 resultados para disposable contact lenses


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To describe the outcome of a series of Acanthamoeba keratitis treated with a similar regimen. Methods: All cases diagnosed with Acanthamoeba keratitis in a referral centre from June 1994 through June 1997 were included. Diagnosis of Acanthamoeba keratitis was based in clinical presentation and laboratory results. Positive laboratory identification of Acanthamoeba from corneal scraping or contact lens was required, unless the patient had very characteristic symptoms (severe pain) and signs of the infection, including perineural infiltrates. Initial intensive treatment included topical polyhexamethylene biguanide (PHMB) 0.02%, propamidine isothionate 0.1% and broad-spectrum antibiotics. The treatment was gradually tapered. After documented response to anti-acanthamoeba therapy, topical steroids were introduced; they were discontinued before cessation of the antiAcanthamoeba regimen. Results: Six males and four females, with a mean age of 30.0 ± 7.4 years were included in this study. All cases weared contact lenses. On presentation all cases had severe pain, and epitheliopathy was associated with stromal infiltrate in most (seven of ten) cases. Four patients had anterior uveitis. Perineural infiltrates were present in three cases and ring infiltrate in one patient. Anti-amoebic treatment was started 12.7 ± 7.2 days after beginning of symptoms. The clinical response to therapy was very satisfactory in all patients. Within two to three weeks all patients had remarkable lessening of pain and photophobia, and improvement of clinical signs. At two to three months, visual acuity had improved in all patients. Two patients required penetrating keratoplasty for visual rehabilitation. Conclusion: The use of PHMB and propamidine cured all cases of Acanthamoeba keratitis. Cautious introduction of steroids was associated with expedited resolution of inflammation and provided symptomatic relief.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Various strategies for ocular drug delivery are considered; from basic formulation techniques for improving availability of drugs; viscosity enhancers and mucoadhesives aid drug retention and penetration enhancers promote drug transport into the eye. The use of drug loaded contact lenses and ocular inserts allows drugs to be better placed where they are needed for more direct delivery. Developments in ocular implants gives a means to overcome the physical barriers that traditionally prevented effective treatment. Implant technologies are under development allowing long term drug delivery from a single procedure, these devices allow posterior chamber diseases to be effectively treated. Future developments could bring artificial corneas to eliminate the need for donor tissue and one-off implantable drug depots lasting the patient’s lifetime.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogels have become very popular due to their unique properties such as high water content, softness, flexibility and biocompatibility. Natural and synthetic hydrophilic polymers can be physically or chemically cross-linked in order to produce hydrogels. Their resemblance to living tissue opens up many opportunities for applications in biomedical areas. Currently, hydrogels are used for manufacturing contact lenses, hygiene products, tissue engineering scaffolds, drug delivery systems and wound dressings. This review provides an analysis of their main characteristics and biomedical applications. From Wichterle’s pioneering work to the most recent hydrogel-based inventions and products on the market, it provides the reader with a detailed introduction to the topic and perspective on further potential developments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: We described the rate of Acanthamoeba keratitis (AK) in a referral eye center in Sao Paulo, Brazil, through a retrospective review of clinical and laboratorial records of patients over 2 decades. Methods: From 1987 to 2006, a total of 581 requests for amoebic laboratory workup in cases of infections keratitis were investigated. Statistical analyses were applied to analyze a tendency of AK cases. Results: Acanthamoeba species were cultured from corneal scrapings of 185 patients, 5 of them with bilateral infection. Eighty-three percent of those patients were related with contact lens wear. Conclusions: The results suggested that patients with AK have persisted and increased over time at our ophthalmology center. Contact lenses showed to be a potential risk factor. Amoebic corneal infection can be considered as a new but well-established disease ill Brazilian ophthalmology and visual sciences.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose:  The purpose of the study was to obtain anterior segment biometry for 40 normal eyes and to measure variables that may be useful to design large diameter gas permeable contact lenses that sit outside the region normally viewed by corneal topographers. Also, the distribution of these variables in the normal eye and how well they correlated to each other were determined.

Methods:  This is a cross-sectional study, in which data were collected at a single study visit. Corneal topography and imaging of the anterior segment of the eye were performed using the Orbscan II and Visante OCT. The variables that were collected were horizontal K reading, central corneal/scleral sagittal depth at 15 mm chord, and nasal and temporal angles at the 15 mm chord using the built-in software measurement tools.

Results:  The central horizontal K readings for the 40 eyes were 43 ± 1.73 D (7.85 ± 0.31 mm), with ± 95% confidence interval (CI) of 38.7 (8.7 mm) and 46.6 D (7.24 mm). The mean corneal/scleral sagittal depth at the 15 mm chord was 3.74 ± 0.19 mm and the range was 3.14 to 4.04 mm. The average nasal angle (which was not different from the temporal angle) at the 15 mm chord was 39.32 ± 3.07 degrees and the ± 95%CI was 33.7 and 45.5 degrees. The correlation coefficient comparing the K reading and the corneal/scleral sagittal depth showed the best correlation (0.58, p < 0.001). The corneal/scleral sagittal depth at 15 mm correlated less with the nasal angle (0.44, p = 0.004) and the weakest correlation was for the nasal angle at 15 mm with the horizontal readings (0.32, p = 0.046).

Conclusion:  The Visante OCT is a valuable tool for imaging the anterior segment of the eye. The Visante OCT is especially effective in providing the biometry of the peripheral cornea and sclera and may help in fitting GP lenses with a higher percentage of initial lens success, when the corneal sag and lens sag are better matched.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of rigid materials with high oxygen permeability (Dk) is on the increase, their major benefit being the reduction of hypoxia. However, there is a reluctance to use these materials possibly due to increased surface scratching, reduced wettability, increased deposition, reduced life expectancy and parameter instability. Considering parameter stability, various studies have demonstrated contradictory results or used high Dk materials based on the silicone acrylate polymer. This study was designed to investigate whether the parameters of a high Dk rigid fluorocarbon contact lens material changed during daily wear and extended wear schedules. Thirty five subjects, divided into group groups, Group I wore the lens on a daily wear basis, whereas those in Group II wore the lens on a monthly extended wear basis. The parameters and integrity of the lenses were monitored in both groups every 3 months. For lens integrity a statistically significant increase in surface scratching was demonstrated for the lenses worn by the subjects of both groups over the time of the study (Group I, F=7.990, P <0.0001 [ANCOVA]; Group II, F=6.241, P=0.003 [ANCOVA]). The only parameter to show a statistically significant variation over the study period was that of centre thickness for the lenses worn by the subjects in Group I (F=3.976, P=0.0063 [ANCOVA]), with a mean reduction in centre thickness of 0.022 mm at the 12 month visit.

No change was noted for either group or between groups for the other parameters measured. This study demonstrates that the parameters of rigid contact lenses manufactured from high Dk fluorocarbons are stable with only a non-clinically significant reduction in centre thickness for the contact lenses worn by the subjects in Group I.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Contact lenses can affect the cornea in a variety of ways. Corneal structure can be altered so that its thickness changes to involve the epithelium and the stroma. As a result, the curvature may be affected, but whether it is the front or the back surface that is affected depends on the type of lens used. If thickness increases sufficiently, corneal transparency may decrease. Contact lenses can also affect cellular structure of all layers of the cornea through mechanical trauma, hypoxia, or toxicity from solutions that are used in association with lenses. More serious complications, such as inflammation and infection, can arise. All these changes can be detected by clinicians using slitlamp biomicroscopes and keratometers if the changes are significant enough. Since the development of computers, optical instruments have become more sophisticated and have enabled the detection of subtle changes but have also facilitated more precise measurement of these conditions along with the ability to capture images of the alterations or defects. This article describes some of the newer techniques and, specifically, the application of optical coherence tomography, confocal microscopy, and esthesiometry.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To report the development of a new apparatus for non-invasive collection of human corneal epithelial cells.

Methods. Previous methods of non-invasive, irrigative corneal cell collection resulted in low cell yields limiting potential analysis. A new ocular surface cell collection apparatus (OSCCA) was designed to collect more epithelial cells from direct irrigation of the corneal surface to allow for clinical comparisons. Forty-five samples were obtained (unilateral or bilateral over seven visits) from five human participants. Cell yield, size, phenotype, and corneal staining (prior and post eye wash) were examined.

Results. On average 364 ± 230 epithelial cells were collected from the cornea per eye. Epithelial cell sizes ranged from 8.21 to 51.69 μm in diameter, and 67.30 to 2098.85 μm2 area. The proportion of corneal specific cells collected per sample was 75 ± 14% as determined by positive K3 expression with AE5. On average, 77 ± 0.2% of epithelial cells harvested were nucleated, the remainder were non-nucleated ghost cells. Corneal staining was reduced in the OSCCA-washed vs. contralateral non-washed eyes (p = 0.02).

Conclusions. The OSCCA allows collection of human corneal epithelial cells with significantly higher yields, and greater specificity than previously reported. Reduced corneal staining observed post eye-wash demonstrated the safety of the technique, and its ability to remove cells directly from the corneal surface. The OSCCA could provide an objective non-invasive method of investigating pathological changes, effects of topical therapeutics, and impact of contact lenses and care-solutions of the cells of the ocular surface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. Various methods have been used in clinical trials to collect time-sensitive subjective responses, including study diaries, telephone interviews, and use of text messaging. However, all of these methods are limited by the uncertainty of when the participants enrolled in the study actually record their responses. This technical note reports on the utility of the BlackBerry smartphone to collect such data and why such a system provides advantages over other methods to report subjective ratings in clinical studies.

Methods. The Centre for Contact Lens Research developed an on-line web-enabled system that permits participants to record and immediately transmit subjective rating scores in numerical form directly into a web-enabled database. This, combined with the utility of BlackBerrys, enabled time-specific e-mail requests to be sent to the study participants and then for that data to be simultaneously transmitted to the web-enabled database. This system has been used in several clinical trials conducted at the Centre for Contact Lens Research, in which data were collected at various times and in several specific locations or environments.

Results. In the clinical trials conducted using this system, participants provided responses on 97.5% of occasions to the requests for data generated by the automated system. When the request was for data on a set date, this method resulted in responses of 84.1% of the time.

Conclusions. The series of clinical trials reported here show the benefits of the utilization of the BlackBerry to collect time- or environment-sensitive data via a web-enabled system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. The purposes of the study were to investigate the test-retest reliability and the validity of new versions of the Melbourne Edge Test (MET) and the High/Low Contrast Visual Acuity (H/LCVA) chart and to investigate the agreement between the original and new versions.

Methods. The MET original photographic version, MET new light box version, H/LCVA Chart original photographic version, H/LCVA Chart new printed version, and the Pelli-Robson chart were administered twice to one eye of 22 subjects with low vision and 20 soft contact lenses wearers.

Results. For the low vision group, the test-retest 95% limits of agreement were ±5.2 dB for the MET new light box version and ±0.39 logarithm of the minimum angle of resolution (logMAR) for the LCVA component of the H/LCVA new printed version. For the soft contact lens group, the test-retest 95% limits of agreement were ±2.1 dB for the MET new light box version and ± 0.26 logMAR for the LCVA component of the H/LCVA new printed version. Moderate to high correlations were obtained between contrast sensitivity tests, thus providing evidence of validity. Scores obtained for the new test versions were significantly higher than the original versions (p < 0.01).

Conclusions. Of all the tests administered, the MET original photographic version and the Pelli-Robson Chart had the highest test-retest reliability for the low vision group. For the soft contact lens group, the H/LCVA original version (low contrast letters, 18% Weber) and the Pelli-Robson Chart had the highest reliability.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Uncorrected refractive error is the leading cause of visual impairment in the world. In Canada there are potentially 2 million people with visual impairment that could be corrected by simply wearing glasses or contact lenses. This number will double in the next 20 years due to Canada’s rapidly ageing population. Visual impairment can seriously affect quality of life. People with vision problems are more likely to fall, have a higher risk of fractures and other injuries, and they may be more likely to limit or stop driving. Visual impairment is also an independent risk factor for increased mortality in older persons.