967 resultados para detectors
Resumo:
Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.
Resumo:
Diplomityön tavoitteena oli selvittää työn toimeksiantajan UPM, Korkeakosken sahan röntgenmittauslaitteen oksaindeksilajitteluparametrille lukuarvo, jolla päästään A-tukkien osalta tavoiteltuun sydänsahatavaralaatujakaumaan eli saadaan siirrettyä VI- sydänsahatavaralaatu B-tukkien joukkoon. Lisäksi työssä tutkittiin sahan tukkilajittelun röntgenmittauslaitteen mittauksen toimivuutta ja sen tehokkaampaa hyödyntämistä. Korkeakosken sahan käyttämä röntgenmittauslaite on Bintec Oy:n kehittämä ja on tyypiltään Wood-X-4D. Laitteen mittaus perustuu tukin kuvaamiseen viipaleinaeli tomografiamittaukseen. Laite mittaa tukista useita ominaisuuksia ja antaa niiden perusteella lajitteluparametreille lukuarvoja. Lajitteluparametriarvojen muuttaminen vaikuttaa syntyvään sydänsahatavaralaatujakaumaan. Työ suoritettiin röntgenmittauslaitteella tekemällä tukeille toistomittauksia ja lajittelukokeita. Kokeissa käytettävät tukit olivat halkaisijaltaan 230 mm - tukkiluokasta. Tukkeja lajiteltiin eri tukkilaatulajitteluasetuksilla, jolloin seurattiin niistä sahattavia sahatavaralaatuja. Sahatavaralaatujen määrityksessä käytettiin sahaosastolla olevaa Finscan Oy:n kehittämää BoardMaster-NT-lajittelumittalaitetta. Tutkimus osoitti, että oksaindeksin pudottamisella, ei päästy työnantajan asettamaan sydänsahatavaran laatulajittelutavoitteeseen sallituissa oksaindeksirajoissa. Tavoitteen saavuttaminen olisi edellyttänyt oksaindeksin arvon pudottamista selkeästi alle asetetun 28 rajan. Tutkimustulokset osoittivat, että röntgenmittalaitteen lajitteluparametrien toiminnan varmuus vaihteli merkittävästi riippuen käytettävästä parametrista ja että laitteen mittaustarkkuus kärsi laitteen yleiseksi viaksi todetun detektorivian myötä. Täten tarkka laatulajittelu edellyttää röntgenmittalaitteen kaikkia neljää toimivaa detektoria. Tämä pystytään varmistamaanvaradetektorilla.
Resumo:
In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.
Resumo:
The following paper introduces the work conducted to create a relative virtual mouse based on the interpretation of head movements and face gesture through a low cost camera and the optical flow of the images. This virtual device is designed specifically as an alternative non-contact pointer for people with mobility impairments in the upper extremities and reduced head control. The proposed virtual device was compared with a conventional mouse, a touchpad and a digital joystick. Validation results show performances close to a digital joystick but far away from a conventional mouse.
Resumo:
The questions studied in this thesis are centered around the moment operators of a quantum observable, the latter being represented by a normalized positive operator measure. The moment operators of an observable are physically relevant, in the sense that these operators give, as averages, the moments of the outcome statistics for the measurement of the observable. The main questions under consideration in this work arise from the fact that, unlike a projection valued observable of the von Neumann formulation, a general positive operator measure cannot be characterized by its first moment operator. The possibility of characterizing certain observables by also involving higher moment operators is investigated and utilized in three different cases: a characterization of projection valued measures among all the observables is given, a quantization scheme for unbounded classical variables using translation covariant phase space operator measures is presented, and, finally, a mathematically rigorous description is obtained for the measurements of rotated quadratures and phase space observables via the high amplitude limit in the balanced homodyne and eight-port homodyne detectors, respectively. In addition, the structure of the covariant phase space operator measures, which is essential for the above quantization, is analyzed in detail in the context of a (not necessarily unimodular) locally compact group as the phase space.
Resumo:
In this work we will prove that SiC-based MIS capacitors can work in environments with extremely high concentrations of water vapor and still be sensitive to hydrogen, CO and hydrocarbons, making these devices suitable for monitoring the exhaust gases of hydrogen or hydrocarbons based fuel cells. Under the harshest conditions (45% of water vapor by volume ratio to nitrogen), Pt/TaOx/SiO2/SiC MIS capacitors are able to detect the presence of 1 ppm of hydrogen, 2 ppm of CO, 100 ppm of ethane or 20 ppm of ethene, concentrations that are far below the legal permissible exposure limits.
Resumo:
ITENE és un institut tecnològic de recerca situat a Paterna (València). Té una plantapilot especialitzada en logística on les empreses que ho vulguin (mitjançant convenis,en règim de lloguer, etc.), poden utilitzar les instal•lacions (magatzem intel•ligent,aplicacions RFID, etc.), per provar els seus productes i simular processos de logística itraçabilitat.En aquesta planta s'ha detectat la necessitat de poder provar nous productes cometiquetes, detectors i processadors equipats amb tecnologia RFID (Identificació perRadiofreqüència). Aquesta tecnologia consisteix en passar informació que conté unaetiqueta “intel•ligent” cap a un terminal (PC) mitjançant uns detectors que, perproximitat, poden llegir la informació. Per exemple, quan un camió ple de mercaderiesprèviament etiquetades, passa per un pòrtic amb detectors RFID, es genera unainformació que passa directament a un terminal. Al moment es pot saber què porta elcamió, quantitat, color, mides, etc. Si això es combina amb un ERP, es pot descomptarde l'estoc en temps real. De fet s'utilitza per moltes aplicacions logística, control deprocessos de fabricació, traçabilitat de productes, etc.Per aquest motiu, ITENE, mitjançant el contacte de AIFOS SOLUTIONS S.L (empresaespecialitzada en RFID) ha encarregat un sistema de transportadors de banda per provarnoves solucions.L'objecte del present projecte consisteix en el disseny i automatització d'un sistema de 4cintes transportadores 2 elevadors per tal de fer un circuit tancat per moure caixes en un“bucle” de forma automàtica. L'objectiu és “llençar” caixes plenes de productes (etiquetats amb RFID) mitjançant untransportador equipat amb un pòrtic que té instal•lats diversos detectors de radiofreqüència,i poder-ne provar la correcta detecció a diferents velocitats. Un “buffer” s'encarrega desubministrar les caixes d'una en una que, un cop acabat el circuit, tornen al lloc d'on hansortit. Per donar un producte per bo, es realitzen tests de diverses hores i se n'obté unaestadística de lectures bones/dolentes. Si la ràtio és la desitjada es dóna per bo elproducte.Per aconseguir un disseny correcte s'ha utilitzat diferents eines CAD per dimensionar elsistema de transportadors i els seus elements. Tota l'aplicació està realitzada en 3Dmitjançant el software AutoCAD 3D. L'abast d'aquest projecte inclourà la solució mecànica i pneumàtica del sistema, aixícom el seu muntatge i tot el referent a les normes de seguretat per tal que el sistemacompleixi la normativa referida a la seguretat de màquines
Resumo:
We present here new observations conducted with the EVN and MERLIN of the persistent microquasar LS 5039 discovered by Paredes et al. (2000) with the VLBA. The new observations confirm the presence of an asymmetric two-sided jet reaching up to 1000 AU on the longest jet arm. The results suggest a bending of the jets with increasing distance from the core and/or precession. The origin and location of the high-energy gamma-ray emission associated with the system is discussed and an estimate of the magnetic field at the base of the jet given. Our results suggest a well collimated radio jet. We also comment on new observing strategies to be used with satellites and forthcoming detectors, since this persistent source appears to be a rather good laboratory to explore the accretion/ejection processes taking place near compact objects.
Resumo:
In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.
Resumo:
Three different pixels based on single-photon avalanche diodes for triggered applications, such as fluorescence lifetime measurements and high energy physics experiments, are presented. Each pixel consists of a 20µm x 100µm (width x length) single photon avalanche diode and a monolithically integrated readout circuit. The sensors are operated in the gated mode of acquisition to reduce the probability to detect noise counts interferring with real radiation events. Each pixel includes a different readout circuit that allows to use low reverse bias overvoltages. Experimental results demonstrate that the three pixels present a similar behaviour. The pixels get rid of afterpulses and present a reduced dark count probability by applying the gated operation. Noise figures are further improved by using low reverse bias overvoltages. The detectors exhibit an input dynamic range of 13.35 bits with short gated"on" periods of 10ns and a reverse bias overvoltage of 0.5V. The three pixels have been fabricated in a standard HV-CMOS process.
Resumo:
Tässä diplomityössä kuvataan Loviisan voimalaitoksen vaihtelevien kontaminaation nuklidijakaumien vaikutusta kontaminaatiomittausten tuloksiin. Nuklidikohtaisten tietojen ja kontaminaation nuklidikoostumuksen selvittämiseen käytettiin epäsuoraa kontaminaationmittausmenetelmää. Valvonta-alueen eri huonetiloista kerättiin pyyhintänäytteitä. Näytteet mitattiin kontaminaatiomittareilla sekä gammaspektrometrisesti radiokemian laboratoriossa. Gamma-analyysissä saatiin selville nuklidikohtaiset aktiivisuudet ja suhteelliset nuklidijakaumat. Kirjallisuudesta etsittiin tiedot kunkin kontaminaatiosta löytyneen nuklidin aktiivisuusominaisuuksille. Säteilyn ilmaisimien havaitsemistehokkuuden energiariippuvuus vaikuttaa kunkin nuklidin mittaustulokseen. Nuklidikohtaisten tietojen sekä tunnettujen energiariippuvuuksien perusteella arvioitiin hiukkasten energiajakauman aiheuttaman mittausvirheen osuutta kullekin nuklidijakaumalle. Tässä tutkimuksessa tarkastellaan lisäksi eri kontaminaatiomittausmenetelmien hyviä ja huonoja puolia. Säteilysuojelutyössä käytetyt kontaminaation mittalaitteet on työssä esitelty ja mittaustarkkuuteen vaikuttavia seikkoja on käsitelty operatiivisen säteilysuojelun kannalta.
Resumo:
Diplomityön tavoitteena on selvittää paperivioista aiheutuvien katkojen syyt paperikoneella ja pyrkiä löytämään ratkaisu ongelmiin erilaisia vianilmaisujärjestelmiä apuna käyttäen. Työssä analysoidaan laatuhylyn synty tuotantolinjan eri kohteissa. Lisäksi tilastoidaan häiriöseisokkisyyt ja sitä kautta pyritään painottamaan kunnossa-pidon tärkeyttä tuotantolinjan tehokkuudessa. Kirjallisuusosassa tutustutaan hyötysuhteen määritelmään ja käsitellään tuotantolinjan hyötysuhteeseen vaikuttavia tekijöitä. Kirjallisuusosassa selvitetään päällystetyn hienopaperin tuoteanalyysin avulla ominaisuudet, joilla on vaikutusta ajettavuuteen ja katkoherkkyyteen on-line päällystävällä hienopaperikoneella. Kokeellisessa osassa selvitetään tuotantoaikaa vähentävien tekijöiden syyt ja mahdolli-set aiheuttajat erilaisten vikaprofiilien avulla. Kokeellisessa osassa analysoidaan myös tuotantolinjan hylyn syntyyn vaikuttavat tekijät ja pyritään minimoimaan hylyn määrä. Pohjapaperin täplät aiheuttivat reikäkatkoja ja hylyn syntymistä kalanterin aukaisujen takia. Reunaviat ja kireysheitot aiheuttivat myös runsaasti katkoja. Lukuisat häiriöseisokit aiheuttivat aikahävikkiä. Häiriöseisokkeja aiheuttivat viat mekaanisissa laitteissa, narujen vaihdot ja rullausruuhkat. Telasuojelun aiheuttamat kalanterin aukaisut olivat työn alussa suurin paperin hylkäyssyy. Telasuojelun optimoinnin ja pohjapaperin täplien määrän vähenemisen myötä telasuojeluaukaisut vähenivät. Lajinvaihdot ja katkot olivat suurimmat hylyn aiheuttajat työn loppuaikana.
Resumo:
Different asymmetries between expansion and contraction (radial motions) have been reported in the literature. Often these patterns have been regarded as implying different channels for each type of radial direction (outward versus inwards) operating at a higher level of visual motion processing. In two experiments (detection and discrimination tasks) we report reaction time asymmetries between expansion and contraction. Power functions were fitted to the data. While an exponent of 0.5 accounted for the expansion data better, a value of unity yielded the best fit for the contraction data. Instead of interpreting these differences as corresponding to different higher order motion detectors, we regard these findings as reflecting the fact that expansion and contraction tap two distinct psychophysical input channels underlying the processing of fast and slow velocities respectively.
Resumo:
Quartz Tuning Fork (QTF)-based Scanning Probe Microscopy (SPM) is an important field of research. A suitable model for the QTF is important to obtain quantitative measurements with these devices. Analytical models have the limitation of being based on the double cantilever configuration. In this paper, we present an electromechanical finite element model of the QTF electrically excited with two free prongs. The model goes beyond the state-of-the-art of numerical simulations currently found in the literature for this QTF configuration. We present the first numerical analysis of both the electrical and mechanical behavior of QTF devices. Experimental measurements obtained with 10 units of the same model of QTF validate the finite element model with a good agreement.
Resumo:
En este trabajo se presenta un estudio químico y estructural de las capas metálicas de Pt y TaSix utilizadas como puerta catalítica en sensores de gas de alta temperatura basados en dispositivos MOS de SiC. Para ello se han depositado capas de diferentes espesores sobre substratos de Si. Los resultados muestran que con la reducción del espesor de Pt y con un recocido se consigue aumentar la rugosidad de las capas de puerta, lo que debería aumentar la sensibilidad y la velocidad de respuesta de los dispositivos que las incorporasen. Otro efecto del recocido es la transformación química del material de la puerta que, para capas delgadas de Pt con TaSix, produce la transformación total Pt en Pt2Ta, lo que podría afectar a las características catalíticas de la puerta. Los primeros resultados eléctricos indican que, a pesar de que las capas de Pt empleadas son gruesas y compactas, los diodos MOS túnel de SiC son sensibles a los gases CO y NO2, aunque presentan una velocidad de respuesta bastante lenta.