918 resultados para clinical protocol
Resumo:
Poster presented at the 1st International Congress of CiiEM - From Basic Sciences to Clinical Research, 27-28 November 2015, Egas Moniz, Caparica, Portugal.
Resumo:
BACKGROUND: There is no evidence-based guidance to facilitate design decisions for confirmatory trials or systematic reviews investigating treatment efficacy for adults with tinnitus. This systematic review therefore seeks to ascertain the current status of trial designs by identifying and evaluating the reporting of outcome domains and instruments in the treatment of adults with tinnitus. METHODS: Records were identified by searching PubMed, EMBASE CINAHL, EBSCO, and CENTRAL clinical trial registries (ClinicalTrials.gov, ISRCTN, ICTRP) and the Cochrane Database of Systematic Reviews. Eligible records were those published from 1 July 2006 to 12 March 2015. Included studies were those reporting adults aged 18 years or older who reported tinnitus as a primary complaint, and who were enrolled into a randomised controlled trial, a before and after study, a non-randomised controlled trial, a case-controlled study or a cohort study, and written in English. Studies with fewer than 20 participants were excluded. RESULTS: Two hundred and twenty-eight studies were included. Thirty-five different primary outcome domains were identified spanning seven categories (tinnitus percept, impact of tinnitus, co-occurring complaints, quality of life, body structures and function, treatment-related outcomes and unclear or not specified). Over half the studies (55 %) did not clearly define the complaint of interest. Tinnitus loudness was the domain most often reported (14 %), followed by tinnitus distress (7 %). Seventy-eight different primary outcome instruments were identified. Instruments assessing multiple attributes of the impact of tinnitus were most common (34 %). Overall, 24 different patient-reported tools were used, predominantly the Tinnitus Handicap Inventory (15 %). Loudness was measured in diverse ways including a numerical rating scale (8 %), loudness matching (4 %), minimum masking level (1 %) and loudness discomfort level (1 %). Ten percent of studies did not clearly report the instrument used. CONCLUSIONS: Our findings indicate poor appreciation of the basic principles of good trial design, particularly the importance of specifying what aspect of therapeutic benefit is the main outcome. No single outcome was reported in all studies and there was a broad diversity of outcome instruments. PROSPERO REGISTRATION: The systematic review protocol is registered on PROSPERO (International Prospective Register of Systematic Reviews): CRD42015017525 . Registered on 12 March 2015 revised on 15 March 2016.
Resumo:
Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.
Resumo:
"May 1991."
Resumo:
Background Many clinical trials of DC-based immunotherapy involve administration of monocyte-derived DCs (Mo-DC) on multiple occasions. We aimed to determine the optimal cell processing procedures and timing (leukapheresis, RBC depletion and cryopreservation) for generation of Mo-DC for clinical purposes. Methods Leukapheresis was undertaken using a COBE Spectra. Two instrument settings were compared - the standard semi-automated software (Version 4.7) (n = 10) and the fully automated software (Version 6.0) (n = 40). Density gradient centrifugation using Ficoll, Percoll, a combination of these methods or neither for RBC depletion were compared. Outcomes (including cell yield and purity) were compared for cryopreserved unmanipulated monocytes and cryopreserved Mo-DC. Results Software Version 6.0 provided significantly better enrichment for monocytes (P
Resumo:
Dendritic cells (DC) from distinct DC subsets are essential contributors to normal human immune responses. Despite this, reliable assays that enable DC to be counted precisely have been slow to evolve. We have now developed a new single-platform flow cytometric assay based on TruCOUN(TM) beads and the whole blood Lyse/No-Wash protocol that allows precise counting of the CD14(-) blood DC subsets: CD11c(+)CD16(-) DC, CD11c(+)CD16(+) DC, CD123(hi) DC, CD1c(+) DC and BDCA-3(+) DC. This assay requires 50 mul of whole blood; does not rely on a hematology blood analyser for the absolute DC counts; allows DC counting in EDTA samples 24 It after collection; and is suitable for cord blood and peripheral blood. The data is highly reproducible with intra-assay and inter-assay coefficients of variation less than 3% and 11%, respectively. This assay does not produce the DC-T lymphocyte conjugates that result in DC counting abnormalities in conventional gradient-density separation procedures. Using the TruCOUNT assay, we established that absolute blood DC counts reduce with age in healthy individuals. In preliminary studies, we found a significantly lower absolute blood CD11c(+)CD16(+) DC count in stage III/IV versus stage I/II breast carcinoma patients and a lower absolute blood CD123(hi) DC count in multiple myeloma patients, compared to age-matched controls. These data indicate that scientific progress in DC counting technology will lead to the global standardization of DC counting and allow clinically meaningful data to be obtained. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The present study investigated body position effects on transient evoked otoacoustic emission (TEOAE) recordings of clinical significance. Sixty adults (30 males, 30 females) were assessed using the Otodynamics ILO88 Analyzer in three positions (sitting, supine, and side-lying). Results indicated significant positional effects on the TEOAE parameters of A-B difference, noise, whole wave reproducibility, and response levels. These differences included higher noise levels in supine and side-lying positions in comparison to the upright sitting position. Lower whole wave reproducibility measurements, and higher response amplitudes, in the side-lying position compared with supine and seated positions were also observed. No significant effects were evident for signal-to-noise ratio or band reproducibility. Given the lack of significant body position effects on these latter parameters and the infrequent clinical use of the other parameters in isolation, there was no evidence to suggest the future need for major review of current pass/fail criteria or of the standard test protocol.
Resumo:
A field-applicable assay for testing anthelmintic sensitivity is required to monitor for anthelmintic resistance. We undertook a study to evaluate the ability of three in vitro assay systems to define drug sensitivity of clinical isolates of the human hookworm parasite Necator americanus recovered from children resident in a village in Madang Province, Papua New Guinea. The assays entailed observation of drug effects on egg hatch (EHA), larval development (LDA), and motility of infective stage larvae (LMA). The egg hatch assay proved the best method for assessing the response to benzimidazole anthelmintics, while the larval motility assay was suitable for assessing the response to ivermectin. The performance of the larval development assay was unsatisfactory on account of interference caused by contaminating bacteria. A simple protocol was developed whereby stool samples were subdivided and used for immediate egg recovery, as well as for faecal culture, in order to provide eggs and infective larvae, respectively, for use in the egg hatch assay and larval motility assay systems. While the assays proved effective in quantifying drug sensitivity in larvae of the drug-susceptible hookworms examined in this study, their ability to indicate drug resistance in larval or adult hookworms remains to be determined. (c) 2005 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Currently 1 in 11 women over the age of 60 in Australia are diagnosed with breast cancer. Following treatment, most breast cancer patients are left with shoulder and arm impairments which can impact significantly on quality of life and interfere substantially with activities of daily living. The primary aim of the proposed study is to determine whether upper limb impairments can be prevented by undertaking an exercise program of prolonged stretching and resistance training, commencing soon after surgery. Methods/design: We will recruit 180 women who have had surgery for early stage breast cancer to a multicenter single-blind randomized controlled trial. At 4 weeks post surgery, women will be randomly assigned to either an exercise group or a usual care ( control) group. Women allocated to the exercise group will perform exercises daily, and will be supervised once a week for 8 weeks. At the end of the 8 weeks, women will be given a home-based training program to continue indefinitely. Women in the usual care group will receive the same care as is now typically provided, i.e. a visit by the physiotherapist and occupational therapist while an inpatient, and receipt of pamphlets. All subjects will be assessed at baseline, 8 weeks, and 6 months later. The primary measure is arm symptoms, derived from a breast cancer specific questionnaire (BR23). In addition, range of motion, strength, swelling, pain and quality of life will be assessed. Discussion: This study will determine whether exercise commencing soon after surgery can prevent secondary problems associated with treatment of breast cancer, and will thus provide the basis for successful rehabilitation and reduction in ongoing problems and health care use. Additionally, it will identify whether strengthening exercises reduce the incidence of arm swelling. Trial Registration: The protocol for this study is registered with the Australian Clinical Trials Registry (ACTRN012606000050550).
Resumo:
Objective To compare the efficacy and safety of two methylphenidate (MPH) formulations—once-daily modified-release MPH (EqXL, Equasym™ XL) and twice-daily immediate-release methylphenidate (MPH-IR, Ritalin®)—and placebo in children with Attention Deficit/Hyperactivity Disorder (ADHD). Methods Children aged 6–12 years on a stable dose of MPH were randomized into a double-blind, three-arm, parallel-group, multi-center study and received 3 weeks of EqXL (20, 40, or 60 mg qd), MPH-IR (10, 20, or 30 mg bid) or placebo. Non-inferiority of EqXL to MPH-IR was assessed by the difference in the inattention/overactivity component of the overall teacher’s IOWA Conners’ Rating Scale on the last week of treatment (per protocol population). Safety was monitored by adverse events, laboratory parameters, vital signs, physical exam, and a Side Effect Rating Scale. Results The lower 97.5% confidence interval bound of the difference between MPH groups fell above the non-inferiority margin (−1.5 points) not only during the last week of treatment but during all three treatment weeks. Both MPH-treatment groups experienced superior benefit when compared to placebo during all treatment weeks (P < 0.001). All treatments were well tolerated. Conclusions EqXL given once-daily was non-inferior to MPH-IR given twice-daily. Both treatments were superior to placebo in reducing ADHD symptoms.
Resumo:
As the first step in developing a protocol for the use of video-phones in community health, we carried out a feasibility study among clients with a range of health needs. Clients were equipped with a commercially available video-phone connected using the client's home telephone line. A hands-free speaker-phone and a miniature video-camera (for close-up views) were connected to the video-phone. Ten clients participated: five required wound care, two palliative care, two long-term therapy monitoring and one was a rural client. All but two were aged 75 years or more. Each client had a video-phone for an average of two to three weeks. During the six months of the study, 43 client calls were made, of which 36 (84%) were converted to video-calls. The speaker-phone was used on 24 occasions (56%) and the close-up camera on 23 occasions (53%). Both clients and nurses rated the equipment as satisfactory or better in questionnaires. None of the nurses felt that the equipment was difficult to use, including unpacking it and setting it up; only one client found it difficult. Taking into account the clients' responses, including their free-text comments, a judgement was made as to whether the video-phone had been useful to their nursing care. In seven cases it was felt to be unhelpful and in three cases it was judged helpful. Although the study sample was small, the results suggest that home telenursing is likely to be useful for rural clients in Australia, unsurprisingly, because of the distances involved.
Resumo:
Random amplification of polymorphic DNA (RAPD) was evaluated as a genotypic method for typing clinical strains of Propionibacterium acnes. RAPD can suffer from problems of reproducibility if parameters are not standardised. In this study the reaction conditions were optimised by adjusting template DNA concentration and buffer constituents. All isolates were typeable using the optimised RAPD protocol which was found to be highly discriminatory (Simpson's diversity index, 0.98) and reproducible. Typing of P. acnes by optimised RAPD is an invaluable tool for the epidemiological investigation of P. acnes for which no other widely accepted method currently exists. © 2003 Federation of European Microbiological Societies. Published by Elsevier B.V. All rights reserved.
Resumo:
The combination of dimethyl dioctadecyl ammonium bromide (DDA) and the synthetic cord factor trehalose dibehenate (TDB) with Ag85B-ESAT-6 (H1 fusion protein) has been found to promote strong protective immune responses against Mycobacterium tuberculosis. The development of a vaccine formulation that is able to facilitate the requirements of sterility, stability and generation of a vaccine product with acceptable composition, shelf-life and safety profile may necessitate selected alterations in vaccine formulation. This study describes the implementation of a sterilisation protocol and the use of selected lyoprotective agents in order to fulfil these requirements. Concomitantly, close analysis of any alteration in physico-chemical characteristics and parameters of immunogenicity have been examined for this promising DDA liposome-based tuberculosis vaccine. The study addresses the extensive guidelines on parameters for non-clinical assessment, suitable for liposomal vaccines and other vaccine delivery systems issued by the World Health Organisation (WHO) and the European Medicines Agency (EMEA). Physical and chemical stability was observed following alteration in formulations to include novel cryoprotectants and radiation sterilisation. Immunogenicity was maintained following these alterations and even improved by modification with lysine as the cryoprotective agent for sterilised formulations. Taken together, these results outline the successful alteration to a liposomal vaccine, representing improved formulations by rational modification, whilst maintaining biological activity.
Resumo:
We argue that, for certain constrained domains, elaborate model transformation technologies-implemented from scratch in general-purpose programming languages-are unnecessary for model-driven engineering; instead, lightweight configuration of commercial off-the-shelf productivity tools suffices. In particular, in the CancerGrid project, we have been developing model-driven techniques for the generation of software tools to support clinical trials. A domain metamodel captures the community's best practice in trial design. A scientist authors a trial protocol, modelling their trial by instantiating the metamodel; customized software artifacts to support trial execution are generated automatically from the scientist's model. The metamodel is expressed as an XML Schema, in such a way that it can be instantiated by completing a form to generate a conformant XML document. The same process works at a second level for trial execution: among the artifacts generated from the protocol are models of the data to be collected, and the clinician conducting the trial instantiates such models in reporting observations-again by completing a form to create a conformant XML document, representing the data gathered during that observation. Simple standard form management tools are all that is needed. Our approach is applicable to a wide variety of information-modelling domains: not just clinical trials, but also electronic public sector computing, customer relationship management, document workflow, and so on. © 2012 Springer-Verlag.