959 resultados para chest-wall rigidity
Resumo:
BACKGROUND: Although there is no strong evidence of benefit, chest physiotherapy (CP) seems to be commonly used in simple pneumonia. CP requires equipment and frequently involves the assistance of a respiratory therapist, engendering a significant medical workload and cost. AIM: To measure and compare the efficacy of two modalities of chest physiotherapy (CP) guideline implementation on the appropriateness of CP prescription among patients hospitalised for community-acquired pneumonia (CAP). PATIENTS AND METHODS: We measured the CP prescription rate and duration in all consecutive CAP inpatients admitted in a division of general internal medicine at an urban teaching community hospital during three consecutive one-year time periods: (1) before any guideline implementation; (2) after a passive implementation by medical grand rounds and guideline diffusion through mailing; (3) after adding a one-page reminder in the CAP patient's medical chart highlighting our recommendations. Death and recurrent hospitalisation rates within one year after hospitalisation were recorded to assess whether CP prescription reduction, if any, impaired patient outcomes. RESULTS: During the three successive phases, 127, 157, and 147 patients with similar characteristics were included. Among all CAP inpatients, the CP prescription rate decreased from 68% (86/127) to 51% (80/157), and to 48% (71/147), respectively (P for trend <0.01 for trend). A significant reduction in CP duration was observed after the active guideline implementation (12.0, 11.0, 7.0days, respectively) and persisted after adjustment for length of stay. Reductions in CP prescription rate and duration were also observed among CAP patients with COPD CP prescription rate: 97% (30/31), 67% (24/36), 75% (35/47), respectively (P<0.01 for trend). The mean cost of CP per patient was reduced by 56%, from $709 to $481, and to $309, respectively. Neither the in-hospital deaths, the one-year overall recurrent hospitalisation nor the one-year CAP-specific recurrent hospitalisation significantly differed between the three phases. CONCLUSION: Both passive and active implementation of guidelines appear to improve the appropriateness of CP prescription among inpatients with CAP without impairing their outcomes. Restricting CP use to patients who benefit from this treatment might be an opportunity to decrease CAP medical cost and workload.
Resumo:
I study a repeated buyer-seller relationship for the exchange of a givengood. Asymmetric information over the buyer's reservation price, which issubject to random shocks, may lead the seller to use a rigid pricing policydespite the possibility of making higher profits through price discriminationacross the different satates of the buyer's reservation price. The existence of a flexible price subgame perfect equilibrium is shown for the buyerssufficiently locked-in. When the seller faces a population of buyers whose degree of involvmentin the relatioship is unknown, the flexible price equilibrium is notnecessarily optimal. Thus tipically the seller will prefer to use therigid price strategy. A learning process allowing the seller to screenthe population of buyers is derived abd the existence of a switching pointbetween the two regimes (i.e. price rigidity and price felxibility) isshown.
Resumo:
Our task in this paper is to analyze the organization of trading in the era of quantitativefinance. To do so, we conduct an ethnography of arbitrage, the trading strategy that bestexemplifies finance in the wake of the quantitative revolution. In contrast to value andmomentum investing, we argue, arbitrage involves an art of association - the constructionof equivalence (comparability) of properties across different assets. In place of essentialor relationa l characteristics, the peculiar valuation that takes place in arbitrage is based on an operation that makes something the measure of something else - associating securities to each other. The process of recognizing opportunities and the practices of making novel associations are shaped by the specific socio-spatial and socio-technical configurations of the trading room. Calculation is distributed across persons and instruments as the trading room organizes interaction among diverse principles of valuation.
Resumo:
In this paper we study the structure of labor market flows in Spain and compare them with France and the US. We characterize a number of empirical regularities and stylized facts. One striking result is that the job finding rate is slightly higher than in France, while the jon loss rate is much higher, putting Spain half-way between France and the US. This suggests that while Spain has borne the full cost of its labor market reforms in terms of job precarity, the benefits in terms of job creation have been quite modest. We hypothesize that this has been due to the reform s credibility being imperfect, which leads toexpectation of reversal.
Resumo:
BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.
Resumo:
ABSTRACT: BACKGROUND: Chest pain raises concern for the possibility of coronary heart disease. Scoring methods have been developed to identify coronary heart disease in emergency settings, but not in primary care. METHODS: Data were collected from a multicenter Swiss clinical cohort study including 672 consecutive patients with chest pain, who had visited one of 59 family practitioners' offices. Using delayed diagnosis we derived a prediction rule to rule out coronary heart disease by means of a logistic regression model. Known cardiovascular risk factors, pain characteristics, and physical signs associated with coronary heart disease were explored to develop a clinical score. Patients diagnosed with angina or acute myocardial infarction within the year following their initial visit comprised the coronary heart disease group. RESULTS: The coronary heart disease score was derived from eight variables: age, gender, duration of chest pain from 1 to 60 minutes, substernal chest pain location, pain increases with exertion, absence of tenderness point at palpation, cardiovascular risks factors, and personal history of cardiovascular disease. Area under the receiver operating characteristics curve was of 0.95 with a 95% confidence interval of 0.92; 0.97. From this score, 413 patients were considered as low risk for values of percentile 5 of the coronary heart disease patients. Internal validity was confirmed by bootstrapping. External validation using data from a German cohort (Marburg, n = 774) revealed a receiver operating characteristics curve of 0.75 (95% confidence interval, 0.72; 0.81) with a sensitivity of 85.6% and a specificity of 47.2%. CONCLUSIONS: This score, based only on history and physical examination, is a complementary tool for ruling out coronary heart disease in primary care patients complaining of chest pain.
Resumo:
Fractures or the medial wall of the orbit are uncommon and clinical signs are often discreet. This report was focused on isolated fractures of the medial wall of the orbit. Blow-out trauma is usually the cause. In these cases the clinical signs ranged from simple ecchymosis to blindness by haematoma of the orbital cone. Computed tomography is a major tool for diagnosis and making therapeutic indications for these fractures. Treatment depends on the oculomotor involvements as measured by forced duction tests.
Resumo:
BACKGROUND: Soft tissue sarcomas of the trunk wall (STS-TW) are usually studied together with soft tissue sarcomas of other locations. We report a study on STS-TW forming part of the French Sarcoma Group database. PATIENTS AND METHODS: Three hundred and forty-three adults were included. We carried out univariate and multivariate analysis for overall survival (OS), metastasis-free survival (MFS) and local recurrence-free survival (LRFS). RESULTS: Tumor locations were as follows: thoracic wall, 82.5%; abdominal wall, 12.3% and pelvic wall, 5.2%. Median tumor size was 6.0 cm. The most frequent tumor types were unclassified sarcoma (27.7%) and myogenic sarcoma (19.2%). A total of 44.6% of cases were grade 3. In all, 21.9% of patients had a previous medical history of radiotherapy (PHR). Median follow-up was 7.6 years. The 5-year OS, MFS and LRFS rates were 60.4%, 68.9% and 58.4%, respectively. Multivariate analysis retained PHR and grade for predicting LRFS and PHR, size and grade as prognostic factors of MFS. Factors influencing OS were age, size, PHR, depth, grade and surgical margins. The predictive factors of incomplete response were PHR, size and T3. CONCLUSIONS: Our results suggest similar classical prognostic factors as compared with sarcomas of other locations. However, a separate analysis of STS-TW revealed a significant poor prognosis subgroup of patients with PHR.
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
Traumatic hernia of the abdominal wall is a rare and easily missed injury in the presence of major pelvic and abdominal lesions. We present a radiographically documented case of combined pelvic and acetabular fracture with a major contralateral traumatic hernia with avulsion of the internal oblique, the external oblique and the transverse abdominal muscles diagnosed four months after the initial trauma. To our knowledge no similar case has been described in the current literature.