971 resultados para broncho-alveolar lavage fluids


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The abrasion seen on some of the retrieved CoCrMo hip joints has been reported to be caused by entrained hard particles in vivo. However, little work has been reported on the abrasion mechanisms of CoCrMo alloy in simulated body environments. Therefore. this study covers the mapping of micro-abrasion wear mechanisms of cast CoCrMo induced by third body hard particles under a wide range of abrasive test conditions. This study has a specific focus on covering the possible in vivo wear modes seen on metal-on-metal (MoM) surfaces. Nano-indentation and nano-scratch tests were also employed to further investigate the secondary wear mechanisms-nano-scale material deformation that involved in micro-abrasion processes. This work addresses the potential detrimental effects of third body hard particles in vivo such as increased wear rates (debris generation) and corrosion (metal-ion release). The abrasive wear mechanisms of cast CoCrMo have been investigated under various wear-corrosion conditions employing two abrasives, SiC (similar to 4 mu m) and Al(2)O(3) (similar to 1 mu m), in two test solutions, 0.9% NaCl and 25% bovine serum. The specific wear rates, wear mechanisms and transitions between mechanisms are discussed in terms of the abrasive size, volume fraction and the test solutions deployed. The work shows that at high abrasive volume fractions, the presence of protein enhanced the wear loss due to the enhanced particle entrainment, whereas at much lower abrasive volume fractions, protein reduced the wear loss by acting as a boundary lubricant or rolling elements which reduced the abrasivity (load per particle) of the abrasive particles. The abrasive wear rate and wear mechanisms of the CoCrMo are dependent on the nature of the third body abrasives, their entrainment into the contact and the presence of the proteins. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human immunodeficiency virus (HIV) is a serious worldwide healthcare problem with implications for all healthcare workers. The reported oral manifestations of the disease are numerous and have been categorised according to the strength of their association with HIV infection. Oral non-Hodgkin's lymphoma is strongly associated with HIV infection, and an increased incidence of such neoplasms is widely reported. This case report details the presentation of a rare subcategory of plasmablastic lymphoma in an HIV-positive patient after administration of an inferior alveolar dental block to facilitate extraction of mandibular teeth. This highly aggressive neoplasm is a large B-cell lymphoma with a predilection for the oral cavity. Unfortunately, the prognosis for such a tumour is poor as detailed in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of any drilling cuttings pile removal process the requirement for monitoring the release of contaminants into the marine environment will be critical. Traditional methods for such monitoring involve taking samples for laboratory analysis. This process is time consuming and only provides data on spot samples taken from a limited number of locations and time frames. Such processes, therefore, offer very restricted information. The need for improved marine sensors for monitoring contaminants is established. We report here the development and application of a multi-capability optical sensor for the real-time in situ monitoring of three key marine environmental and offshore/oil parameters: hydrocarbons, synthetic-based fluids and heavy metal concentrations. The use of these sensors will be a useful tool for real-time in situ environmental monitoring during the process of decommissioning offshore structures. Multi-capability array sensors could also provide information on the dispersion of contamination from drill cuttings piles either while they are in situ or during their removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute respiratory distress syndrome (ARDS) is a devastating disorder characterized by increased alveolar permeability with no effective treatment beyond supportive care. Current mechanisms underlying ARDS focus on alveolar endothelial and epithelial injury caused by products of innate immune cells and platelets. However, the role of adaptive immune cells in ARDS remains largely unknown. In this study, we report that expansion of Ag-specific αβTh17 cells contributes to ARDS by local secretion of IL-17A, which in turn directly increases alveolar epithelial permeability. Mice with a highly restrictive defect in Ag-specific αβTh17 cells were protected from experimental ARDS induced by a single dose of endotracheal LPS. Loss of IL-17 receptor C or Ab blockade of IL-17A was similarly protective, further suggesting that IL-17A released by these cells was responsible for this effect. LPS induced a rapid and specific clonal expansion of αβTh17 cells in the lung, as determined by deep sequencing of the hypervariable CD3RβVJ region of the TCR. Our findings could be relevant to ARDS in humans, because we found significant elevation of IL-17A in bronchoalveolar lavage fluid from patients with ARDS, and rIL-17A directly increased permeability across cultured human alveolar epithelial monolayers. These results reveal a previously unexpected role for adaptive immune responses that increase alveolar permeability in ARDS and suggest that αβTh17 cells and IL-17A could be novel therapeutic targets for this currently untreatable disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nontypeable Haemophilus influenzae (NTHI) is an opportunistic pathogen that is an important cause of acute exacerbations of chronic obstructive pulmonary disease (AECOPD). COPD is an inflammatory disease of the airways, and exacerbations are acute inflammatory events superimposed on this background of chronic inflammation. Azithromycin (AZM) is a macrolide antibiotic with antibacterial and anti-inflammatory properties and a clinically proven potential for AECOPD prevention and management. Relationships between AZM efficacy and resistance by NTHI and between bactericidal and immunomodulatory effects on NTHI respiratory infection have not been addressed. In this study, we employed two pathogenic NTHI strains with different AZM susceptibilities (NTHI 375 [AZM susceptible] and NTHI 353 [AZM resistant]) to evaluate the prophylactic and therapeutic effects of AZM on the NTHI-host interplay. At the cellular level, AZM was bactericidal toward intracellular NTHI inside alveolar and bronchial epithelia and alveolar macrophages, and it enhanced NTHI phagocytosis by the latter cell type. These effects correlated with the strain MIC of AZM and the antibiotic dose. Additionally, the effect of AZM on NTHI infection was assessed in a mouse model of pulmonary infection. AZM showed both preventive and therapeutic efficacies by lowering NTHI 375 bacterial counts in lungs and bronchoalveolar lavage fluid (BALF) and by reducing histopathological inflammatory lesions in the upper and lower airways of mice. Conversely, AZM did not reduce bacterial loads in animals infected with NTHI 353, in which case a milder anti-inflammatory effect was also observed. Together, the results of this work link the bactericidal and anti-inflammatory effects of AZM and frame the efficacy of this antibiotic against NTHI respiratory infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glibenclamide (GLIB), an oral antidiabetic medication of the sulphonylurea drugs family, was stoichiometrically imprinted using tetrabutylammonium methacrylate as the functional monomer, for the first time in molecular imprinting, and utilising the sulphonylurea affinity for carboxylate anions. Solution association between the drug and the novel functional monomer was studied by 1H-NMR titrations, whereby evidence of sulphonylurea deprotonation followed by the formation of “narcissistic” GLIB dimers was found when tested in CDCl3, while an affinity constant in excess of 105 L mol-1 was measured in DMSO-d6. Detailed analysis of GLIB binding on the subsequently prepared imprinted and non-imprinted polymers confirmed deactivation of binding sites by exchange of a proton between GLIB and methacrylate, followed by extraction of the tetrabutylammonium counterion from the polymer matrix, resulting in overall reduced binding capacities and affinities by the imprinted material under equilibrium conditions. An optimised MI-SPE protocol, which included a binding site re-activation step, was developed for the extraction of GLIB from blood serum, whereby recoveries of up to 92.4% were obtained with exceptional sample clean-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os coeficientes de difusão (D 12) são propriedades fundamentais na investigação e na indústria, mas a falta de dados experimentais e a inexistência de equações que os estimem com precisão e confiança em fases comprimidas ou condensadas constituem limitações importantes. Os objetivos principais deste trabalho compreendem: i) a compilação de uma grande base de dados para valores de D 12 de sistemas gasosos, líquidos e supercríticos; ii) o desenvolvimento e validação de novos modelos de coeficientes de difusão a diluição infinita, aplicáveis em amplas gamas de temperatura e densidade, para sistemas contendo componentes muito distintos em termos de polaridade, tamanho e simetria; iii) a montagem e teste de uma instalação experimental para medir coeficientes de difusão em líquidos e fluidos supercríticos. Relativamente à modelação, uma nova expressão para coeficientes de difusão a diluição infinita de esferas rígidas foi desenvolvida e validada usando dados de dinâmica molecular (desvio relativo absoluto médio, AARD = 4.44%) Foram também estudados os coeficientes de difusão binários de sistemas reais. Para tal, foi compilada uma extensa base de dados de difusividades de sistemas reais em gases e solventes densos (622 sistemas binários num total de 9407 pontos experimentais e 358 moléculas) e a mesma foi usada na validação dos novos modelos desenvolvidos nesta tese. Um conjunto de novos modelos foi proposto para o cálculo de coeficientes de difusão a diluição infinita usando diferentes abordagens: i) dois modelos de base molecular com um parâmetro específico para cada sistema, aplicáveis em sistemas gasosos, líquidos e supercríticos, em que natureza do solvente se encontra limitada a apolar ou fracamente polar (AARDs globais na gama 4.26-4.40%); ii) dois modelos de base molecular biparamétricos, aplicáveis em todos os estados físicos, para qualquer tipo de soluto diluído em qualquer solvente (apolar, fracamente polar e polar). Ambos os modelos dão origem a erros globais entre 2.74% e 3.65%; iii) uma correlação com um parâmetro, específica para coeficientes de difusão em dióxido de carbono supercrítico (SC-CO2) e água líquida (AARD = 3.56%); iv) nove correlações empíricas e semi-empíricas que envolvem dois parâmetros, dependentes apenas da temperatura e/ou densidade do solvente e/ou viscosidade do solvente. Estes últimos modelos são muito simples e exibem excelentes resultados (AARDs entre 2.78% e 4.44%) em sistemas líquidos e supercríticos; e v) duas equações preditivas para difusividades de solutos em SC-CO2, em que os erros globais de ambas são inferiores a 6.80%. No global, deve realçar-se o facto de os novos modelos abrangerem a grande variedade de sistemas e moléculas geralmente encontrados. Os resultados obtidos são consistentemente melhores do que os obtidos com os modelos e abordagens encontrados na literatura. No caso das correlações com um ou dois parâmetros, mostrou-se que estes mesmos parâmetros podem ser ajustados usando um conjunto muito pequeno de dados, e posteriormente serem utilizados na previsão de valores de D 12 longe do conjunto original de pontos. Uma nova instalação experimental para medir coeficientes de difusão binários por técnicas cromatográficas foi montada e testada. O equipamento, o procedimento experimental e os cálculos analíticos necessários à obtenção dos valores de D 12 pelo método de abertura do pico cromatográfico, foram avaliados através da medição de difusividades de tolueno e acetona em SC-CO2. Seguidamente, foram medidos coeficientes de difusão de eucaliptol em SC-CO2 nas gamas de 202 – 252 bar e 313.15 – 333.15 K. Os resultados experimentais foram analisados através de correlações e modelos preditivos para D12.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

First year nursing students repeatedly have difficulty recalling, understanding, and applying knowledge from the Fluids & Electrolytes (F&E) class. Although the traditional teaching method of lecturing is appropriate in a situation of knowledge acquisition, this situation refers to a broader context. An alternate teaching method is needed to increase students' understanding of the previously acquired knowledge and its application. This research concerns gaming as a tool for teaching with the focus on process as well as product. An instructional exercise, in the Jeopardy format, is designed to incorporate understanding (through problem-solving), group collaboration, and metacognition. Constructivist philosophy is combined with Instructional Design to construct an exercise that focuses not only on knowledge recall, but also emphasizes thinking, understanding, and the reflective nature of the exercise. The focus of this research is to design and evaluate an exercise as a supplemental teaching method to the lecture presentation of the F&E class.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At an intermediate or advanced stage, i.e. stage B or C, based on the Barcelona Clinic Liver Cancer classification of hepatocellular carcinoma (HCC), transarterial chemoembolization (TACE) may be offered as a treatment of palliative intent. We report the case of a patient suffering from acute respiratory distress syndrome after TACE with drug-eluting beads loaded with doxorubicin for HCC. To our knowledge, this is the first case described where a bronchoalveolar lavage was performed, and where significant levels of alveolar eosinophilia and neutrophilia were evident, attributed to a pulmonary toxicity of doxorubicin following liver chemoembolization. © 2014 S. Karger AG, Basel.