985 resultados para aortic valve


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A 49-year-old male patient presented with a paravalvular leakage 18 years after aortic valve replacement. The patient received a mechanical valve and was weaned uneventfully from cardiopulmonary bypass. After a drop in the pressure curve of the left radial artery an additional line was placed in the proximal ascending aorta showing normal systemic pressure. Transesophageal echocardiography showed a massive circular thrombosis of the distal aortic arch. The patient received a covered stent to expand the residual aortic lumen and left the hospital in good health.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A 12 yr old Dalmatian was referred for evaluation of acute lethargy, fever, neurologic signs, and a recently ausculted heart murmur. Echocardiography in combination with blood cultures resulted in a diagnosis of nonhospital-acquired Serratia marcescens bacteremia and aortic valve endocarditis. Despite early diagnosis and aggressive therapy, the dog failed to respond to antimicrobials and died within 6 hr after admission. Necropsy findings included aortic valve endocarditis, septicemia, and diffuse thromboembolic disease. There was no history of pre-existing underlying disease or immunosuppressive therapy, and the dog had not been hospitalized before referral.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In a patient with staphylococcus lugdunensis prosthetic aortic valve endocarditis and coronary septic embolism accompanied by antero-lateral myocardial infarction, embolic material was successfully aspirated from the bifurcation of the left anterior descending coronary artery and the first diagonal branch. A good angiographic result was documented six months thereafter when the patient presented with a second complication, pulsatile compression of the left main coronary artery by an abscess cavity originating between the aortic and mitral annulus, leading to congestive heart failure. The patient underwent successful surgical replacement of the aortic valve prosthesis with concomitant patch reconstruction of the annulus as well as tricuspid annuloplasty.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coronary artery disease (CAD) and aortic stenosis (AS) share pathophysiological mechanisms and risk factors. Moreover, the prevalence of CAD increases among elderly patients with severe AS since disease progression is strongly associated with age for both CAD and AS. These factors contribute to the frequent coexistence of CAD and AS. Patients with concomitant AS and CAD are characterised by higher baseline risk profiles with a larger number of comorbidities as compared to patients with isolated AS. Therefore, adequate therapeutic strategies are crucial for the treatment of these patients. The number of patients undergoing concomitant coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) doubled during the last decade. Moreover, the development and rapid integration of transcatheter aortic valve implantation (TAVI) into clinical practice in western European countries has further extended invasive treatment of AS to elderly high-risk patients not considered suitable candidates for SAVR, frequently presenting with CAD. The aim of this review article is to provide an overview on CAD prevalence, impact on clinical outcomes, and treatment strategies in patients with severe AS requiring SAVR or TAVI.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Atrioventricular (AV) conduction disturbances requiring permanent pacemaker (PPM) implantation may complicate transcatheter aortic valve replacement (TAVR). Available evidence on predictors of PPM is sparse and derived from small studies. Objectives The objective of this study was to provide summary effect estimates for clinically useful predictors of PPM implantation after TAVR. Methods We performed a systematic search for studies that reported the incidence of PPM implantation after TAVR and that provided raw data for the predictors of interest. Data on study, patient, and procedural characteristics were abstracted. Crude risk ratios (RRs) and 95% confidence intervals for each predictor were calculated by use of random effects models. Stratified analyses by type of implanted valve were performed. Results We obtained data from 41 studies that included 11,210 TAVR patients, of whom 17% required PPM implantation after intervention. The rate of PPM ranged from 2% to 51% in individual studies (with a median of 28% for the Medtronic CoreValve Revalving System [MCRS] and 6% for the Edwards SAPIEN valve [ESV]). The summary estimates indicated increased risk of PPM after TAVR for men (RR: 1.23; p < 0.01); for patients with first-degree AV block (RR: 1.52; p < 0.01), left anterior hemiblock (RR: 1.62; p < 0.01), or right bundle branch block (RR: 2.89; p < 0.01) at baseline; and for patients with intraprocedural AV block (RR: 3.49; p < 0.01). These variables remained significant predictors when only patients treated with the MCRS bioprosthesis were considered. The data for ESV were limited. Unadjusted estimates indicated a 2.5-fold higher risk for PPM implantation for patients who received the MCRS than for those who received the ESV. Conclusions Male sex, baseline conduction disturbances, and intraprocedural AV block emerged as predictors of PPM implantation after TAVR. This study provides useful tools to identify high-risk patients and to guide clinical decision making before and after intervention.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE To assess long-term clinical outcomes of consecutive high-risk patients with severe aortic stenosis according to treatment allocation to transcatheter aortic valve implantation (TAVI), surgical aortic valve replacement (SAVR) or medical treatment (MT). METHODS Patients with severe aortic stenosis were consecutively enrolled into a prospective single centre registry. RESULTS Among 442 patients (median age 83 years, median STS-score 4.7) allocated to MT (n=78), SAVR (n=107), or TAVI (n=257) all-cause mortality amounted to 81%, 37% and 43% after a median duration of follow-up of 3.9 years (p<0.001). Rates of major adverse cerebro-cardiovascular events were lower in patients undergoing SAVR or TAVI as compared with MT (SAVR vs MT: HR 0.31, 95% CI 0.21 to 0.46) (TAVI vs MT: HR 0.34, 95% CI 0.25 to 0.46), with no significant difference between SAVR and TAVI (HR 0.88, 95% CI 0.62 to 1.25). Whereas SAVR (HR 0.39, 95% CI 0.24 to 0.61), TAVI (HR 0.37, 95% CI 0.26 to 0.52), and female gender (HR 0.72, 95% CI 0.53 to 0.99) were associated with improved survival, body mass index ≤20 kg/m(2) (HR 1.60, 95% CI 1.04 to 2.47), diabetes (HR 1.48, 95% CI 1.03 to 2.12), peripheral vascular disease (HR 2.01, 95% CI 1.44 to 2.81), atrial fibrillation (HR 1.74, 95% CI 1.28 to 2.37) and pulmonary hypertension (HR 1.43, 95% CI 1.03 to 2.00) were identified as independent predictors of mortality. CONCLUSIONS Among high-risk patients with severe aortic stenosis, long-term clinical outcome through 5 years was comparable between patients allocated to SAVR or TAVI. In contrast, patients with MT had a dismal prognosis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Low-flow, low-gradient severe aortic stenosis (AS) is characterised by a small aortic valve area (AVA) and low mean gradient (MG) secondary to a low cardiac output and may occur in patients with either a preserved or reduced left ventricular ejection fraction (LVEF). Symptomatic patients presenting with low-flow, low-gradient severe AS have a dismal prognosis independent of baseline LVEF if managed conservatively and should therefore undergo aortic valve replacement if feasible. Transthoracic echocardiography (TTE) is the first-line investigation for the assessment of AS haemodynamic severity. However, when confronted with guideline-discordant AVA (small) and MG (low) values, there are several reasons other than severe AS combined with a low cardiac output which may lead to such a situation, including erroneous measurements, small body size, inherent inconsistencies in the guidelines' criteria, prolonged ejection time and aortic pseudostenosis. The distinction between these various entities poses a diagnostic challenge. However, it is important to make a distinction because each has very different implications in terms of risk stratification and therapeutic management. In such instances, cardiac catheterisation forms an integral part of the work-up of these patients in order to confirm or refute the echocardiographic findings to guide management decisions appropriately.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Objectives We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. Methods Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with an average follow-up time of 5.9±2.6 years (maximum 9.6 years) and a total of 885.3 patient years. Results Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n=1] and 4.0% for combined procedures [n=3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2±23.0 mmHg (48.6 ± 16.3 mmHg) decreased to 15.6±5.4 (8.8±3.0) after AVR, and remained low for up to 9 years. The postoperative effective orifice area (EOA) was 1.6 ±0.57 cm2, 1.90±0.45 cm2, 2.12±0.48 cm2 and 2.20±0.66 cm2 for the valve sizes 21, 23, 25 and 27, respectively; with absence of severe prosthesis-patient-mismatch (PPM) and 0.7% (n=1) moderate PPM. During follow-up, Twenty-six patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation and SVD at 9 years averaged 0.57 [0.47‒0.66], 0.82 [0.69‒0.90] and 0.70 [0.57‒0.79], respectively. Conclusions The Freedom SOLO stentless aortic valve is safe to implant and shows excellent early and mid-term hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5 ̶ 6 years and the need for explantation increased markedly, suggesting low durability.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES Long-term follow-up reports after implantation of the Shelhigh® (Shelhigh, Inc., NJ, USA) No-React® aortic valved conduit used for aortic root replacement do not exist. METHODS Between November 1998 and December 2007, the Shelhigh® No-React® aortic valved conduit was implanted in 291 consecutive patients with a mean age of 69.6 ± 9.1 years, and 33.7% were female (n = 98). Indications were annulo-aortic ectasia (n = 202), aortic valve stenosis combined with ascending aortic aneurysm (n = 67), acute type A aortic dissection (n = 29), endocarditis (n = 26) and other related pathologies (n = 48) including 62 patients with previous cardiac surgery. Data from two cardiac institutions were analysed retrospectively using SPSS (SPSS Software IBM, Inc., 2014, NY, USA). RESULTS Operative mortality was 10% (n = 29). Main cause of death was cardiac failure in 15 patients (51.8%), neurological events in 6 patients (20.7%), respiratory failure in 4 patients (13.8%), bleeding complications in 2 patients (6.9%) and gastrointestinal ischaemia in 2 cases (6.9%). There were 262 hospital survivors and all were entered in the follow-up study (100% complete). During the long-term follow-up (mean 70.3 ± 53.1 in months), a total of 126/262 patients (44.3%) died. Main causes of death in patients after discharge were cardiac (n = 37, 14.1%), neurological (n = 15, 5.7%) respiratory (n = 12, 4.6%), endocarditis (n = 12, 4.6%) and peripheral vascular disease (n = 5, 1.9%). In 29 (11.1%) patients, the cause of death could not be determined. Reoperation was required in 25 (8.6%) patients due to infection of the conduit (n = 9), aortoventricular disconnection (n = 4), pseudoaneurysm formation (n = 4) and structural valve degeneration (n = 8). Reoperations were performed 5.0 ± 3.8 (range 0.1-11.7) years after index surgery. CONCLUSIONS The Shelhigh® No-React® aortic valved conduit showed satisfactory short-term operative results. However, the long-term follow-up revealed a relatively high rate of deaths, which may be explained by the epidemiology of the patient group, but a substantial proportion of deaths could not be clarified. The overall rate of reoperation (8.6%) during the mid-term follow-up is worrisome and the failures due to aortoventricular disconnection, endocarditis and pseudoaneurysm formation remain unexplained. The redo-procedures were technically demanding. We recommend close follow-up of patients with the Shelhigh® No-React® aortic valved conduit, because besides classical structural valve degeneration, unexpected findings may be observed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) has been established as a less invasive alternative to open-heart surgery in inoperable or high-risk patients presenting with symptomatic severe aortic valve stenosis. The feasibility and efficacy of valve-in-valve implantation in degenerated surgical aortic bioprostheses have also been described and can currently be considered a valuable treatment option in patients deemed unsuitable for repeat cardiac surgery. However, the clinical use of TAVR devices is not limited to the treatment of the tricuspid stenotic aortic valve. Several additional indications including treatment of the bicuspid stenotic aortic valve, aortic regurgitation, and valve-in-valve or valve-in-ring implantation in the mitral or tricuspid position as well as treatment of pure mitral, tricuspid, or pulmonary regurgitation have been described. The purpose of the present review is to summarize the available evidence concerning the emerging off-label use of TAVR devices in current clinical practice. Case examples have been selected to highlight the main procedural steps of each particular intervention.