876 resultados para Visual Analog Scale


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The activation of 5-hydroxytryptamine-3 (5-HT-3) receptors in spinal cord can enhance intrinsic spinal mechanisms of central hypersensitivity, possibly leading to exaggerated pain responses. Clinical studies suggest that 5-HT-3 receptor antagonists may have an analgesic effect. This randomized, double-blind, placebo-controlled crossover study tested the hypothesis that the 5-HT-3 receptor antagonist tropisetron attenuates pain and central hypersensitivity in patients with chronic low back pain. Thirty patients with chronic low back pain, 15 of whom were women (aged 53 ± 14 years) and 15 men (aged 48 ± 14 years), were studied. A single intravenous injection of 0.9% saline solution, tropisetron 2mg, and tropisetron 5mg was administrated in 3 different sessions, in a double-blind crossover manner. The main outcome was the visual analogue scale (VAS) score of spontaneous low back pain before, and 15, 30, 60, and 90 minutes after drug administration. Secondary outcomes were nociceptive withdrawal reflexes to single and repeated electrical stimulation, area of reflex receptive fields, pressure pain detection and tolerance thresholds, conditioned pain modulation, and area of clinical pain. The data were analyzed by analysis of variance and panel multiple regressions. All 3 treatments reduced VAS scores. However, there was no statistically significant difference between tropisetron and placebo in VAS scores. Compared to placebo, tropisetron produced a statistically significant increase in pain threshold after single electrical stimulation, but no difference in all other secondary outcomes was found. A single-dose intravenous administration of tropisetron in patients with chronic low back pain had no significant specific effect on intensity of pain and most parameters of central hypersensitivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate implant accuracy and cosmetic outcome of a new intraoperative patient-specific cranioplasty method after convexity meningioma resection. METHODS: The patient's own bone flap served as a template to mold a negative form with the use of polymethyl methacrylate (PMMA). The area of bone invasion was determined and broadly excised under white light illumination with a safety margin of at least 1 cm. The definitive replica was cast within the remaining bone flap frame and the imprint. Clinical and radiologic follow-up examinations were performed 3 months after surgery. RESULTS: Four women and two men (mean age 51.4 years ± 12.8) underwent reconstruction of bone flap defects after meningioma resection. Mean duration of intraoperative reconstruction of the partial bone flap defects was 19 minutes ± 4 (range 14-24 minutes). Implant sizes ranged from 17-35 cm(2) (mean size 22 cm(2) ± 8). Radiologic and clinical follow-up examinations revealed excellent implant alignment and favorable cosmesis (visual analogue scale for cosmesis [VASC] = 97 ± 5) in all patients. CONCLUSIONS: Patient-specific reconstruction of partial bone flap defects after convexity meningioma resection using the presented intraoperative PMMA cast method resulted in excellent bony alignment and a favorable cosmetic outcome. Relatively low costs and minimized operation time for adjustment and insertion of the cranioplasty implant justify use of this method in small bony defects as well.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gynecomastia is the most common breast pathology. Numerous excisions and liposuction techniques have been described to correct bilateral male breast enlargement. Recently, there has been a shift from the open approach to minimally invasive techniques. This article reports a 5-year experience using laser-assisted lipolysis (LAL) to treat gynecomastia, and describes the surgical technique. Between January 2006 and December 2010, a total of 28 patients with bilateral gynecomastia were treated with LAL. Patients had a mean age of 36.5 years (range 24 to 56 years). LAL was performed with a 980-nm diode laser (continuous emission, 15 W power, 8-12 kJ total energy per breast) after tumescent anesthetic infiltration. The breast was evaluated objectively by two physicians who compared chest circumference and photographs. Patients were also asked to score the results using a visual analogue scale: 75 to 100 (very good), 50-74 (good), 25 to 49 (fair) and 0 to 24 (poor). The postoperative period for all patients was incident-free. After 6 months, 18 patients (64.3%) scored the results as "very good", 6 as "good" (21.4%), 3 as "fair" (10.7%) and 1 "poor" (3.6%). Mean chest circumferences pre- and postoperatively were, respectively, 117.4 ± 11.1 cm and 103.3 ± 7.5 cm (p < 0.001), corresponding to a mean difference of 14.1 cm. Physicians scored the photographs as "very good" in 22 patients (78.6%), as "good" in five patients (17.9%), and as "fair" in one patient (3.6%). LAL in gynecomastia is safe and produces significant effects on fatty tissue, with a reduction in breast volume, together with significant skin tightening. Provided an appropriate amount of energy is delivered by an experienced operator, the results are both significant and consistent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the study was to analyse the aesthetic evaluation of head photographs of treated individuals with clefts by laypeople and professionals and to investigate how certain cephalometric variables could be related to their rating. A set of five standardized head photos (frontal, both laterals, three-quater right and left) of 12 Caucasian patients with treated unilateral cleft lip and palate were presented to 12 adult laypeople, 12 orthodontists, and 12 maxillofacial surgeons. For each set of photos the judges had to answer four questions on a visual analogue scale (VAS). The answers were analysed for intra- and inter-panel level of agreement and correlations of assessments with certain cephalometric parameters were determined. There was a high level of agreement for all assessments of each panel of raters. However, laypeople were less satisfied with lip and nose aesthetics compared to professionals. The three groups were similarly satisfied with the aesthetics of the jaws and the face. The anterior position of the maxilla (SNA) influenced positively professionals' ratings of facial aesthetics. Orthodontists were negatively influenced when the vertical dimension of the face or the distance of the lower lip to E-plane were relatively increased. The latter was the only cephalometric parameter correlated with lower aesthetic scores obtained from laypeople. Professionals report greater satisfaction from the treatment outcome and evaluate cleft consequences with less severity than laypeople. According to cephalometric findings, the relative positions of the lips seem to dominate facial aesthetics' appreciation by laypeople, while specialists appear to focus on different features of the face.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to describe the sciatic-femoral nerve block (SFNB) in goats and to evaluate the peri-operative analgesia when the goats underwent stifle arthrotomy. The animals were randomly assigned to one of four treatment groups: groups 0.25, 0.5 and 0.75 received 0.25%, 0.5% and 0.75% of bupivacaine, respectively, while group C (control group) received 0.9% NaCl. In all groups, the volume administered was 0.2 mL/kg. Intra-operatively, the proportion of animals receiving rescue propofol was significantly lower in groups 0.5 and 0.75, compared to group C. Post-operatively, the visual analogue scale (VAS) and total pain score were significantly higher in group C than in the other groups. Group 0.75 had the highest percentage of animals showing motor blockade. SFNB performed with bupivacaine resulted in better intra- and post-operative analgesia than SFNB performed with saline. Compared to the other concentrations, 0.5% bupivacaine resulted in satisfactory analgesia with acceptable side effects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Efficacy of medications for recurrent airway obstruction is typically tested using clinical, cytological and lung function examinations of severely affected animals. These trials are technically challenging and may not adequately reflect the spectrum of disease and owner complaints encountered in clinical practice. OBJECTIVE: To determine if owners of horses with chronic airway disease are better able to detect drug efficacy than a veterinarian who clinically examines horses infrequently. METHOD: In a double-blinded randomised controlled trial, owners and a veterinarian compared the efficacy of dexamethasone (0.1 mg/kg bwt per os, q. 24 h, for 3 weeks; n = 9) to placebo (n = 8) in horses with chronic airway disease. Before and after treatment, owners scored performance, breathing effort, coughing and nasal discharge using a visual analogue scale (VAS). The clinician recorded vital parameters, respiratory distress, auscultation findings, cough and nasal discharge, airway mucus score, bronchoalveolar lavage fluid (BALF) cytology and arterial blood gases. RESULTS: The VAS score improved significantly in dexamethasone- but not placebo-treated horses. In contrast, the clinician failed to differentiate between dexamethasone- and placebo-treated animals based on clinical observations, BALF cytology or endoscopic mucus score. Respiratory rate (RR) and arterial oxygen pressure (PaO(2)) improved with dexamethasone but not placebo. CONCLUSIONS AND CLINICAL RELEVANCE: In the design of clinical trials of airway disease treatments, more emphasis should be placed on owner-assessed VAS than on clinical, cytological and endoscopic observations made during brief examinations by a veterinarian. Quantifiable indicators reflecting lung function such as RR and PaO(2) provide a good assessment of drug efficacy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cranioplasty is a common neurosurgical procedure. Free-hand molding of polymethyl methacrylate (PMMA) cement into complex three-dimensional shapes is often time-consuming and may result in disappointing cosmetic outcomes. Computer-assisted patient-specific implants address these disadvantages but are associated with long production times and high costs. In this study, we evaluated the clinical, radiological, and cosmetic outcomes of a time-saving and inexpensive intraoperative method to mold custom-made implants for immediate single-stage or delayed cranioplasty. Data were collected from patients in whom cranioplasty became necessary after removal of bone flaps affected by intracranial infection, tumor invasion, or trauma. A PMMA replica was cast between a negative form of the patient's own bone flap and the original bone flap with exactly the same shape, thickness, and dimensions. Clinical and radiological follow-up was performed 2 months post-surgery. Patient satisfaction (Odom criteria) and cosmesis (visual analogue scale for cosmesis) were evaluated 1 to 3 years after cranioplasty. Twenty-seven patients underwent intraoperative template-molded patient-specific cranioplasty with PMMA. The indications for cranioplasty included bone flap infection (56%, n = 15), calvarian tumor resection (37%, n = 10), and defect after trauma (7%, n = 2). The mean duration of the molding procedure was 19 ± 7 min. Excellent radiological implant alignment was achieved in 94% of the cases. All (n = 23) but one patient rated the cosmetic outcome (mean 1.4 years after cranioplasty) as excellent (70%, n = 16) or good (26%, n = 6). Intraoperative cast-molded reconstructive cranioplasty is a feasible, accurate, fast, and cost-efficient technique that results in excellent cosmetic outcomes, even with large and complex skull defects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this prospective multicenter study, tinnitus loudness and tinnitus-related distress were investigated in 174 cochlear implant (CI) candidates who underwent CI surgery at a Swiss cochlear implant center. All subjects participated in two session, one preoperatively and one 6 months after device activation. In both sessions, tinnitus loudness was assessed using a visual analogue scale and tinnitus distress using a standardized tinnitus questionnaire. The data were compared with unaided pre- and postoperative pure tone thresholds, and postoperative speech reception scores. 71.8% of the subjects reported tinnitus preoperatively. Six months after CI surgery 20.0% of these reported abolition of their tinnitus, 51.2% a subjective improvement, 21.6% no change and 7.2% a deterioration. Of the 49 (28.2%) subjects with no tinnitus preoperatively, 5 developed tinnitus 6 months after CI. These 5 had poorer speech understanding after CI surgery with their device than the group who remained tinnitus free. We found no correlation between tinnitus improvement, age, duration of tinnitus, or change in unaided hearing thresholds between the two sessions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although a reduced olfactory/gustatory function affects patients in all parts of life, this problem has not received much attention in Wegener's granulomatosis (WG). The aim of this study was to assess the smell/taste function of WG patients. Demographic data of 16 WG patients (9 males, 7 females) were obtained. They all subjectively assessed their taste/smell function on visual analogue scale. Olfactory/gustatory functions of the patients were tested with 'Sniffin' Sticks and 'Taste' strips, respectively. The results were then compared with those from sex and age-matched control group (n = 16) and normative data. WG patients subjectively assessed their olfactory (p = 0.03) and gustatory (p = 0.02) function to be lower than control group. All the olfactory scores (odour identification, odour discrimination and threshold) in both genders were significantly below the scores in the control group. WG patients were hyposmic. For taste (total taste score, as well as scores for the qualities sweet, sour, salty and bitter), WG patients did not significantly differ from controls and were normogeusic. However, the gustatory scores showed the tendency of reduction as compared to the control group. In conclusion, WG patients truly suffer from olfactory/taste dysfunction, but this is worse with olfaction. It is, therefore, imperative that physicians should make their patients to be aware of these sensory dysfunctions and educate them on methods to cope with it for better quality of life.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: In the present cohort study, overdentures with a combined root and implant support were evaluated and compared with either exclusively root- or implant-supported overdentures. Results of a 2-year follow-up period are reported, namely survival of implants, root copings, and prostheses, plus prosthetic complications, maintenance service, and patient satisfaction. MATERIALS AND METHODS: Fourteen patients were selected for the combined overdenture therapy and were compared with 2 patient groups in which either roots or implants provided overdenture support. Altogether, 14, 17, and 15 patients (in groups 1, 2, and 3, respectively) were matched with regard to age, sex, treatment time, and observation period. The mean age was around 67 years. Periodontal parameters were recorded, radiographs were taken, and all complications and failures were registered during the entire observation time. The patients answered a 9-item questionnaire by means of a visual analogue scale (VAS). RESULTS: One implant failed and 1 tooth root was removed following longitudinal root fracture. Periodontal/peri-implant parameters gave evidence of good oral hygiene for roots and implants, and slight crestal bone resorption was measured for both. Technical complications and service performed were significantly higher in the first year (P < .04) in all 3 groups and significantly higher in the tooth root group (P < .03). The results of the VAS indicated significantly lower scores for satisfaction, speaking ability, wearing comfort, and denture stability with combined or exclusive root support (P < .05 and .02, respectively). Initial costs of overdentures with combined or root support were 10% lower than for implant overdentures. CONCLUSION: The concept of combined root and implant support can be integrated into treatment planning and overdenture design for patients with a highly reduced dentition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes the results of a unique "natural experiment" of the operation and cessation of a broadcast transmitter with its short-wave electromagnetic fields (6-22 MHz) on sleep quality and melatonin cycle in a general human population sample. In 1998, 54 volunteers (21 men, 33 women) were followed for 1 week each before and after shut-down of the short-wave radio transmitter at Schwarzenburg (Switzerland). Salivary melatonin was sampled five times a day and total daily excretion and acrophase were estimated using complex cosinor analysis. Sleep quality was recorded daily using a visual analogue scale. Before shut down, self-rated sleep quality was reduced by 3.9 units (95% CI: 1.7-6.0) per mA/m increase in magnetic field exposure. The corresponding decrease in melatonin excretion was 10% (95% CI: -32 to 20%). After shutdown, sleep quality improved by 1.7 units (95% CI: 0.1-3.4) per mA/m decrease in magnetic field exposure. Melatonin excretion increased by 15% (95% CI: -3 to 36%) compared to baseline values suggesting a rebound effect. Stratified analyses showed an exposure effect on melatonin excretion in poor sleepers (26% increase; 95% CI: 8-47%) but not in good sleepers. Change in sleep quality and melatonin excretion was related to the extent of magnetic field reduction after the transmitter's shut down in poor but not good sleepers. However, blinding of exposure was not possible in this observational study and this may have affected the outcome measurements in a direct or indirect (psychological) way.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Transsexualism occurs with an estimated prevalence of 2.4:100,000 male-to-female (MTF) and 1:100,000 female-to-male (FTM) transsexuals. As sex reassignment surgery involves surgery of the urethra and transsexuals are substituted life-long with the cross gender hormones there could possibly arise micturition disorders. Aim of the study was to determine if transsexuals have an increased risk of micturition disorders and if so which. STUDY DESIGN: Between January and July 2003 we examined 25 transsexuals whereof 18 were MTF and 7 were FTM transsexuals using King's Health Questionnaire, visual analogue scale for patient's well being, perineal and transabdominal ultrasound, urine dipstick and uroflow measurement. RESULTS: 17 out of 25 patients considered themselves very happy. In MTF transsexuals, a diverted stream, overactive bladder and stress urinary incontinence was a common problem. Prostate volume was small with 20 g and palpation did not confirm and solid or suspicious lesions. None of the patients had significant residual urine but MTF transsexuals had a reduced urinary flow. We could not detect a current urinary tract infections in any of the patients. CONCLUSION: Transsexuals have an increased risk for the development of micturition disorders including stress urinary incontinence and overactive bladder compared to age-matched control groups and should be counselled preoperatively. Reasons for the development of incontinence might be surgery including pudendal nerve damage, hormonal reasons and ageing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The technique of the osteotome-mediated transcrestal sinus floor elevation is described in a series of case reports. Fifty-five patients received a total of 66 implants over a period of 6 years. Bio-Oss was added in more than 60% of cases to increase the stability of the lifted area. The surgical procedure appeared to be a safe method that was well supported by the patients. It was applied for different prosthetic indications in partially and completely edentulous situations. The survival rate of the implants during the healing phase was 98.5%, and it was 100% after loading. The patients' responses to the Summers technique were evaluated by means of short interviews and visual analog scales (VAS), and the answers were compared with those from a group of patients who had received implants in the same location during the same period but without the osteotome technique. The answers regarding pain were not different between the groups. However, significantly more patients who had received the implants by means of the osteotome technique judged the surgical procedure as highly uncomfortable. It is concluded that patients need to be well prepared for the procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Previous meta-analyses described moderate to large benefits of chondroitin in patients with osteoarthritis. However, recent large-scale trials did not find evidence of an effect. PURPOSE: To determine the effects of chondroitin on pain in patients with osteoarthritis. DATA SOURCES: The authors searched the Cochrane Central Register of Controlled Trials (1970 to 2006), MEDLINE (1966 to 2006), EMBASE (1980 to 2006), CINAHL (1970 to 2006), and conference proceedings; checked reference lists; and contacted authors. The last update of searches was performed on 30 November 2006. STUDY SELECTION: Studies were included if they were randomized or quasi-randomized, controlled trials that compared chondroitin with placebo or with no treatment in patients with osteoarthritis of the knee or hip. There were no language restrictions. DATA EXTRACTION: The authors extracted data in duplicate. Effect sizes were calculated from the differences in means of pain-related outcomes between treatment and control groups at the end of the trial, divided by the pooled SD. Trials were combined by using random-effects meta-analysis. DATA SYNTHESIS: 20 trials (3846 patients) contributed to the meta-analysis, which revealed a high degree of heterogeneity among the trials (I2 = 92%). Small trials, trials with unclear concealment of allocation, and trials that were not analyzed according to the intention-to-treat principle showed larger effects in favor of chondroitin than did the remaining trials. When the authors restricted the analysis to the 3 trials with large sample sizes and an intention-to-treat analysis, 40% of patients were included. This resulted in an effect size of -0.03 (95% CI, -0.13 to 0.07; I2 = 0%) and corresponded to a difference of 0.6 mm on a 10-cm visual analogue scale. A meta-analysis of 12 trials showed a pooled relative risk of 0.99 (CI, 0.76 to 1.31) for any adverse event. LIMITATIONS: For 9 trials, the authors had to use approximations to calculate effect sizes. Trial quality was generally low, heterogeneity among the trials made initial interpretation of results difficult, and exploring sources of heterogeneity in meta-regression and stratified analyses may be unreliable. CONCLUSIONS: Large-scale, methodologically sound trials indicate that the symptomatic benefit of chondroitin is minimal or nonexistent. Use of chondroitin in routine clinical practice should therefore be discouraged.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Family needs and expectations are often unmet in the intensive care unit (ICU), leading to dissatisfaction. This study assesses cross-cultural adaptability of an instrument evaluating family satisfaction in the ICU. MATERIALS AND METHODS: A Canadian instrument on family satisfaction was adapted for German language and central European culture and then validated for feasibility, validity, internal consistency, reliability, and sensitivity. RESULTS: Content validity of a preliminary translated version was assessed by staff, patients, and next of kin. After adaptation, content and comprehensibility were considered good. The adapted translation was then distributed to 160 family members. The return rate was 71.8%, and 94.4% of questions in returned forms were clearly answered. In comparison with a Visual Analogue Scale, construct validity was good for overall satisfaction with care (Spearman rho = 0.60) and overall satisfaction with decision making (rho = 0.65). Cronbach alpha was .95 for satisfaction with care and .87 for decision-making. Only minor differences on repeated measurements were found for interrater and intrarater reliability. There was no floor or ceiling effect. CONCLUSIONS: A cross-cultural adaptation of a questionnaire on family satisfaction in the ICU can be feasible, valid, internally consistent, reliable, and sensitive.