959 resultados para Vertical load influence
Resumo:
In canine visceral leishmaniasis (CVL), the abnormalities most commonly observed in clinical examination on the animals are lymphadenomegaly and skin lesions. Dogs are the main domestic reservoir for the protozoon Leishmania (L.) chagasi and the skin is the main site of contamination by the vector insect. Some protozoa use apoptosis as an immunological escape mechanism. The aim of this study was to correlate the presence of apoptosis with the parasite load and with the inflammatory response in the skin and lymph nodes of dogs naturally infected with Leishmania (L.) chagasi. Thirty-three dogs from the municipality of Araçatuba (São Paulo, Brazil) were used, an endemic area for CVL. Muzzle, ear and abdominal skin and the popliteal, subscapular, iliac and mesenteric lymph nodes of symptomatic (S), oligosymptomatic (O) and asymptomatic (A) dogs were analyzed histologically. The parasite load and percentage apoptosis were evaluated using an immunohistochemical technique. Microscopically, the lymph nodes presented chronic lymphadenitis and the skin presented plasmacytic infiltrate and granulomatous foci in the superficial dermis, especially in the ear and muzzle regions. The inflammation was most severe in group S. The parasite load and apoptotic cell density were also greatest in this group. The cause of the lymphoid atrophy in these dogs was correlated with T lymphocyte apoptosis, thus leaving the dogs more susceptible to CVL. The peripheral lymph nodes presented the greatest inflammatory response. Independent of the clinical picture, the predominant inflammatory response was granulomatous and plasmacytic, both in the skin and in the peripheral lymph nodes. The ear skin presented the greatest intensity of inflammation and parasite load, followed by the muzzle skin, in group S. The ear skin area presented a non-significant difference in cell profile, with predominance of macrophages, and a significant difference from group A to groups O and S. It was seen that in these areas, there were high densities of parasites and cells undergoing apoptosis, in group S. The association between apoptosis and parasite load was not significant in the lymph nodes, but in the muzzle regions and at the ear tips, a positive correlation was seen between the parasite load and the density of cells undergoing apoptosis. The dogs in group S had the highest parasite load and the greatest number of apoptotic cells, thus suggesting that the parasite had an immune evasion mechanism, which could be proven statistically in the skin. © 2012 Elsevier B.V.
Resumo:
Objective: To investigate the influence of the convergence angle of tooth preparation on the fracture load of Y-TZP-based ceramic (YZ-Vita YZ) substructure (SB) veneered with a feldspathic porcelain (VM9-Vita VM9). Methods: Finite element stress analysis (FEA) was performed to examine the stress distribution of the system. Eighty YZ SB were fabricated using a CAD-CAM system and divided into four groups (n = 20), according to the total occlusal convergence (TOC) angle: G6-6° TOC; G12-12° TOC; G20-20° TOC; and G20MOD-20° TOC with modified SB. All SB were veneered with VM9, cemented in a fiber reinforced epoxy resin die, and loaded to failure. Half of the specimens from each group (n = 10) were cyclic fatigued (106 cycles) before testing. Failure analysis was performed to determine the fracture origin. Data were statistically analyzed using Anova and Tukey's tests (α = 0.05). Results: The greatest mean load to fracture value was found for the G20MOD, which was predicted by the FEA. Cyclic fatigue did not significantly affect the load of fracture. Catastrophic failure originating from the internal occlusal surface of the SB was the predominant failure mode, except for G20MOD. Significance: The YZ-VM9 restorations resisted greater compression load than the usual physiological occlusal load, regardless of the TOC angle of preparations. Yet, the G20MOD design produced the best performance among the experimental conditions evaluated. © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: To investigate the influence of the presence or absence of keratinized mucosa on the alveolar bony crest level as it relates to different buccal marginal bone thicknesses. Material and methods: In six beagle dogs, the mandibular premolars and first molars were extracted bilaterally. In the right side of the mandible (test), flaps were elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. The flap was released coronally to allow a primary wound closure. In the left side, the wounds were left unsutured with the keratinized mucosa remaining (control). After 3 months of healing, a complete absence of keratinized mucosa was found at the test sites. Two recipient sites were prepared at each side of the mandible, one in the premolar and one in the molar region. A buccal bony ridge width of approximately 1 and 2 mm was obtained at the premolar and molar region, respectively. Implants were installed with the shoulder flush with the buccal alveolar bony crest, and abutments were connected to allow a nonsubmerged healing. At least 2 mm of keratinized mucosa was surrounding the control sites, while at the test sites, the implants were bordered by alveolar mucosa. After 3 months, the animals were euthanized and ground sections obtained. Results: A higher vertical bony crest resorption was observed at the test compared with the control sites both at the premolar and molar regions, the differences being statistically significant. The top of the peri-implant mucosa was located more coronally at the control compared with the test sites. The horizontal resorption measured 1 mm below the implant shoulder was similar at the test and control sites. Only limited differences were found between premolar and molar sites, with the exclusion of the horizontal resorption that was higher at the test compared with the control sites. Conclusions: A higher alveolar buccal bony crest resorption and a more apical soft tissue marginal position should be expected, when implants are surrounded with thin alveolar mucosa at the time of installation, independently of the thickness of the buccal bony crest. © 2013 John Wiley & Sons A/S.
Resumo:
The aim of this study was to evaluate the stress distribution in implants of regular platforms and of wide diameter with different sizes of hexagon by the 3-dimensional finite element method. We used simulated 3-dimensional models with the aid of Solidworks 2006 and Rhinoceros 4.0 software for the design of the implant and abutment and the InVesalius software for the design of the bone. Each model represented a block of bone from the mandibular molar region with an implant 10 mm in length and different diameters. Model A was an implant 3.75 mm/regular hexagon, model B was an implant 5.00 mm/regular hexagon, and model C was an implant 5.00 mm/ expanded hexagon. A load of 200 N was applied in the axial, lateral, and oblique directions. At implant, applying the load (axial, lateral, and oblique), the 3 models presented stress concentration at the threads in the cervical and middle regions, and the stress was higher for model A. At the abutment, models A and B showed a similar stress distribution, concentrated at the cervical and middle third; model C showed the highest stresses. On the cortical bone, the stress was concentrated at the cervical region for the 3 models and was higher for model A. In the trabecular bone, the stresses were less intense and concentrated around the implant body, and were more intense for model A. Among the models of wide diameter (models B and C), model B (implant 5.00 mm/regular hexagon) was more favorable with regard to distribution of stresses. Model A (implant 3.75 mm/regular hexagon) showed the largest areas and the most intense stress, and model B (implant 5.00 mm/regular hexagon) showed a more favorable stress distribution. The highest stresses were observed in the application of lateral load.
Resumo:
Objectives: This study evaluated the gloss behaviour of experimental resin composites loaded with different filler percentages, immediately after polishing and after toothbrushing simulation. Methods: Sixteen disc-shaped specimens were fabricated for each different-charged composite (40%, 50%, 60%, 70% and 75%) and polished with SiC abrasive papers. Gloss measurements were made prior to simulated toothbrushing. The specimens were subjected to the simulation for 5, 15, 30 and 60 min using an electrical toothbrush with a standardized pressure while being immersed in a toothpaste/artificial saliva slurry. Results: Baseline composite gloss values ranged from 69.7 (40%) to 81.3 (75%) GU (gloss units) and from 18.1 (40%) to 32.3 (75%) GU after 1 h of brushing. Highest gloss values were obtained by 75%-charged resin, while the lowest values were obtained by the 40%-charged one. Conclusions: All tested materials showed a gloss decrease. However, the higher filler load a composite resin has, the higher gloss it can achieve. Clinical significance: Gloss of resin composite materials is an important factor in determining aesthetic success of anterior restorations, and this property may vary according to the filler charge of the restorative material. Higher filler load of a composite resin results in higher gloss values. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O puncionamento é normalmente uma situação crítica no projeto de lajes lisas de concreto armado. Segundo várias normas de projeto, o puncionamento se desenvolve de maneira ainda mais desfavorável nos casos onde o carregamento atua de forma assimétrica, graças a momentos desbalanceados na ligação laje-pilar. Visando avaliar as recomendações normativas para estas situações, foram ensaiadas 12 lajes lisas unidirecionais de concreto armado ( c f ' entre 36 e 58 MPa) submetidas a puncionamento simétrico ou assimétrico. As lajes apresentavam dimensões de (1.800 x 1.800 x 110) mm com carregamento sendo aplicado através de uma chapa metálica simulando um pilar quadrado com (85 x 85 x 50) mm. O trabalho teve como variáveis, além da posição de carregamento, a taxa de armadura na direção transversal, objetivando avaliar a influência destas armaduras na resistência última ao puncionamento de lajes lisas unidirecionais. São apresentados e analisados os resultados dos deslocamentos verticais, deformações na superfície de concreto e nas armaduras de flexão, mapas de fissuração, cargas últimas e modos de ruptura observados. Apresentam-se ainda os resultados da avaliação das recomendações de 6 normas de projeto, sendo 3 européias e 1 norte americana, além das versões de 1978 e 2003 da norma brasileira para projeto de estruturas de concreto. Foi realizada também uma análise numérica utilizando o Método dos Elementos Finitos para idealizar o comportamento das lajes, comparando-se os resultados desta análise elástica com aqueles verificados experimentalmente. Os resultados indicaram que, ao contrário do que as normas prescrevem, a resistência ao puncionamento não diminui de forma linear com o aumento da excentricidade do carregamento, com a flexão influenciando significativamente na resistência última ao puncionamento. Os resultados indicam também que, mesmo em lajes unidirecionais, a taxa de armadura transversal apresenta influência significativa na distribuição dos esforços na laje, interferindo na resistência à punção.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)