940 resultados para Underwater Acoustics
Resumo:
Sound source localization (SSL) is an essential task in many applications involving speech capture and enhancement. As such, speaker localization with microphone arrays has received significant research attention. Nevertheless, existing SSL algorithms for small arrays still have two significant limitations: lack of range resolution, and accuracy degradation with increasing reverberation. The latter is natural and expected, given that strong reflections can have amplitudes similar to that of the direct signal, but different directions of arrival. Therefore, correctly modeling the room and compensating for the reflections should reduce the degradation due to reverberation. In this paper, we show a stronger result. If modeled correctly, early reflections can be used to provide more information about the source location than would have been available in an anechoic scenario. The modeling not only compensates for the reverberation, but also significantly increases resolution for range and elevation. Thus, we show that under certain conditions and limitations, reverberation can be used to improve SSL performance. Prior attempts to compensate for reverberation tried to model the room impulse response (RIR). However, RIRs change quickly with speaker position, and are nearly impossible to track accurately. Instead, we build a 3-D model of the room, which we use to predict early reflections, which are then incorporated into the SSL estimation. Simulation results with real and synthetic data show that even a simplistic room model is sufficient to produce significant improvements in range and elevation estimation, tasks which would be very difficult when relying only on direct path signal components.
Resumo:
An Ultrasound-assisted preparation of a series of novel 3,5-diaryl-4,5-dihydro-1H-pyrazole-1-carboximidamides that proceeds via the efficient reaction of chalcones with aminoguanidine hydrochloride under clean conditions is described. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
An efficient and green synthesis of thiocarbamoyl-3,5-diaryl-4,5-dihydro-1 H-pyrazoles via the condensation of chalcones with thiosemicarbazide in ethanol and KOH under ultrasound irradiation is reported. The products were isolated in good yields after short reaction times. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In order to effectively suppress the noise radiation from large electrical power transformers, both the structure-borne and air-borne sound fields need to be characterised. The characterisation can be made either from theoretical predictions or by in-situ measurements. This paper presents the study of the sound radiation from a large power transformer in a substation. The radiation pattern can be predicted from the measured acceleration distribution and the predicted value is not affected by other noise sources. Alternatively, the farfield sound pressure level can be predicted from the sound pressure level measured at NEMA locations. Both the near- and far-field power radiation can be in-situ measured using the sound intensity technique. It is shown that both the vibration of a transformer tank wall and the radiated noise consist of a series of tonal components mainly at the first few harmonic frequencies of 100 Hz. Also, the neglect of the noise radiation from the transformer (top and bottom) lids does not affects the accuracy of the transformer radiation characterisation. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
New techniques in air-displacement plethysmography seem to have overcome many of the previous problems of poor reproducibility and validity. These have made body-density measurements available to a larger range of individuals, including children, elderly and sick patients who often have difficulties in being submerged underwater in hydrodensitometry systems. The BOD POD air-displacement system (BOD POD body composition system; Life Measurement Instruments, Concord, CA, USA) is more precise than hydrodensitometry, is simple and rapid to operate (approximately 1 min measurements) and the results agree closely with those of hydrodensitometry (e.g. +/-3.4% for estimation of body fat). Body line scanners employing the principles of three-dimensional photography are potentially able to measure the surface area and volume of the body and its segments even more rapidly (approximately 10 s), but the validity of the measurements needs to be established. Advances in i.r. spectroscopy and mathematical modelling for calculating the area under the curve have improved precision for measuring enrichment of (H2O)-H-2 in studies of water dilution (CV 0.1-0.9% within the range of 400-1000 mu l/l) in saliva, plasma and urine. The technique is rapid and compares closely with mass spectrometry (bias 1 (SD 2) %). Advances in bedside bioelectrical-impedance techniques are making possible potential measurements of skinfold thicknesses and limb muscle mass electronically. Preliminary results suggest that the electronic method is more reproducible (intra-and inter-individual reproducibility for measuring skinfold thicknesses) and associated with less bias (+ 12%), than anthropometry (+ 40%). In addition to these selected examples, the 'mobility' or transfer of reference methods between centres has made the distinction between reference and bedside or field techniques less distinct than in the past.
Resumo:
General measures of reaction to noise, which assess the respondent's perceived affectedness or dissatisfaction, appear to be more valid and internally consistent than more narrow measures, such as specific assessment of noise annoyance. However, the test-retest reliability of general and specific measures has yet to be compared. As a part of the large-scale Sydney Airport Health Study, 97 respondents participated in the same interview twice, several weeks apart. Test-retest reliabilities were found to be significant (p
Resumo:
Complications related to renal transplants have been widely reported in the literature. The most common complications include acute tubular necrosis, rejection, perirenal fluid collections, vascular complications, and urinary tract obstruction, which are promptly identified by imaging studies. Here we report a case of a patient with a rare cause of obstruction: a ureteral inguinal hernia. This is the sixth report of this condition, and, to our knowledge, no previous case has been reported in which sonography played an important role in promptly identifying the underlying condition and allowing additional less hazardous studies, therefore aiding case management.
Resumo:
This study aimed at verifying the effects of phonophoresis associated with Arnica montana on the acute phase of an inflammatory muscle lesion. Forty Wistar male rats (300 +/- 50 g), of which the Tibialis Anterior muscle was surgically lesioned, were divided into four groups (n = 10 each): control group received no treatment; the ultrasound group (US) was treated in pulsed mode with 1-MHz frequency, 0.5 W/cm(2) intensity (spatial and temporal average - SATA), duty cycle of 1: 2 (2 ms on, 4 ms off, 50%), time of application 3 min per session, one session per day, for 3 days; the phonophoresis or ultrasound plus arnica (US+A) group was treated with arnica with the same US parameters plus arnica gel; and the arnica group (A) was submitted to massage with arnica gel, also for 3 min, once a day, for 3 days. Treatment started 24 h after the surgical lesion. On the 4th day after lesion creation, animals were sacrificed and sections of the lesioned, inflamed muscle were removed for quantitative (mononuclear and polymorphonuclear cell count) and qualitative histological analysis. Collected data from the 4 groups were statistically analyzed and the significance level set at p < 0.05. Results show higher mononuclear cell density in all three treated groups with no significant difference between them, but values were significantly different (p < 0.0001) when compared to control group`s. As to polymorphonuclear cell density, significant differences were found between control group (p = 0.0134) and US, US+A and A groups; the arnica group presented lesser density of polymorphonuclear cells when compared (p = 0.0134) to the other groups. No significant difference was found between US and US+A groups. While the massage with arnica gel proved to be an effective anti-inflammatory on acute muscle lesion in topic use, these results point to ineffectiveness of Arnica montana phonophoresis, US having seemingly checked or minimized its anti-inflammatory effect. (C) 2008 Elsevier B. V. All rights reserved.
Resumo:
Morbid obesity is highly prevalent in the Western World, and its consequences present a real public health challenge. Voice alterations can represent one of these consequences and represent an opportunity for interference with therapeutic methods. This particularly features of the individual`s voice was the goal of the present study. A group of 45 adult volunteers of both sexes with a BMI greater than 35 Kg/m(2) was selected among patients of the Obesity Ambulatory of the Digestive Surgery Division. The control group consisted of volunteers matched by sex, age (+/- 1 year), and smoking habits, but with a BMI bellow 30 Kg/m(2). All subjects were submitted to laryngoscopic examination, audio perceptive analysis, and voice acoustics determination. Examinations were always performed by the same doctor, and diagnoses were provided by two different physician specialists in laryngology and voice. Obese individuals exhibit the following modifications in voice feature: hoarseness, murmuring, vocal instability, altered jitter and shimmer, and reduced maximum phonation times as well the presence of voice strangulation at the end of emission. The voices of individuals with morbid obesity are different of the voice of nonobese people and demonstrate significant changes in vocal characteristics.
Resumo:
The metallic voice is usually confused with ring or nasality by singers and nontrained listeners. who are not used to perceptual vocal analysis. They believe a metallic voice results from a rise in fundamental frequency. A diagnostic error in this aspect may lead to lowering pitch, an incorrect procedure that Could Cause vocal overload and fatigue. The purpose of this article is to Study the quality of metallic voice considering the correlation between information of the physiological and acoustic plans, based on a perceptive consensual assumption. Fiberscopic video pharyngolaryngoscopy was performed on 21 professional singers while speaking vowel [e]-in normal and metallic modes to observe muscular movements and structural changes of the velopharynx, pharynx, and larynx. Vocal samples captured simultaneously to the fiberscopic examination were acoustically analyzed. Frequency and amplitude of the first four formants (F(1), F(2), F(3), and F(4)) were extracted by means of linear predictor coefficients (LPC) Spectrum and were statistically analyzed. Vocal tract adjustments such as velar lowering, pharyngeal wall narrowing, laryngeal rise, aryepiglottic, and lateral laryngeal constrictions were frequently found: there were no significant changes in frequency and amplitude of F(1) in the metallic voiced there were significant increases in amplitudes of F(2), F(3), and F(4) and in frequency for F, metallic Voice perceived as louder was correlated to an increase ill amplitude of F(3) and F(4). Physiological adjustments of velopharynx, pharynx, and larynx are combined in characterizing the metallic voice and can be acoustically related to changes in formant pattern.
Resumo:
Objective. The purpose of this study was to estimate the Down syndrome detection and false-positive rates for second-trimester sonographic prenasal thickness (PT) measurement alone and in combination with other markers. Methods. Multivariate log Gaussian modeling was performed using numerical integration. Parameters for the PT distribution, in multiples of the normal gestation-specific median (MoM), were derived from 105 Down syndrome and 1385 unaffected pregnancies scanned at 14 to 27 weeks. The data included a new series of 25 cases and 535 controls combined with 4 previously published series. The means were estimated by the median and the SDs by the 10th to 90th range divided by 2.563. Parameters for other markers were obtained from the literature. Results. A log Gaussian model fitted the distribution of PT values well in Down syndrome and unaffected pregnancies. The distribution parameters were as follows: Down syndrome, mean, 1.334 MoM; log(10) SD, 0.0772; unaffected pregnancies, 0.995 and 0.0752, respectively. The model-predicted detection rates for 1%, 3%, and 5% false-positive rates for PT alone were 35%, 51%, and 60%, respectively. The addition of PT to a 4 serum marker protocol increased detection by 14% to 18% compared with serum alone. The simultaneous sonographic measurement of PT and nasal bone length increased detection by 19% to 26%, and with a third sonographic marker, nuchal skin fold, performance was comparable with first-trimester protocols. Conclusions. Second-trimester screening with sonographic PT and serum markers is predicted to have a high detection rate, and further sonographic markers could perform comparably with first-trimester screening protocols.
Resumo:
Objective. The purpose of this study was to construct nomograms of placental volumes according to gestational age and estimated fetal weight. Methods. From March to November 2007, placental volumes were prospectively measured by ultrasonography in 295 normal pregnancies from 12 to 40 weeks` gestation and correlated with gestational age and estimated fetal weight. Inclusion criteria were healthy women, singleton pregnancies with normal fetal morphologic characteristics on ultrasonography, and confirmed gestational age by first-trimester ultrasonography. Results. The mean placental volume ranged from 83 cm(3) at 12 weeks to 427.7 cm(3) at 40 weeks. Linear regression yielded the following formula for the expected placental volumes (ePV) according to gestational age (GA): ePV` (cm(3)) = -64.68 + 12.31 x GA (r = 0.572; P < .001). Placental volumes also varied according to estimated fetal weight (EFW), and the following mathematical equation was also obtained by linear regression: ePV = 94.19 + 0.09 x EFW (r = 0.505; P < 0.001). Conclusions. Nomograms of placental volumes according to gestational age and estimated fetal weight were constructed, generating reference values.
Resumo:
Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Lymphangioma is a rare benign tumor characterized by proliferating lymph vessels and composed of large cyst spaces with endothelium-lined channels of varying dimensions. The incidence of lymphangioma is approximately one in 6000 pregnancies. Less than 1 % of lymphangiomas are purely mediastinal. The great majority of cases are of cystic lymphangioma, but very rarely there is a mixed lesion consisting of multiple cysts of dilated capillary and lymph vessels. We report a case of posterior mediastinal lymphangioma diagnosed at 28 weeks` gestation, in which three-dimensional ultrasonography was helpful in determining the precise location of the tumor. A Cesarean section was performed at 39 weeks and the tumor was resected on the 5(th) day postdelivery; histological examination revealed a mixed cystic lymphangioma. Copyright (C) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
The aim of this study was to evaluate the effect of the pulsed ultrasound therapy (PUT) in stimulating myoregeneration and collagen deposition in an experimental model of lacerative gastrocnemius muscle lesion in 30 Wistar rats. Fifteen rats were treated (TG) daily with 1 MHz pulsed ultrasound (50%) at 0.57 W/cm(2) for 5 min, and 15 were control animals (CG). Muscle samples were analyzed on postoperative days 4, 7 and 14 through H&E, Picrosirius-polarization and immunohistochemistry for desmin. The lesions presented similar inflammatory responses in both treated and control groups. The areal fraction of fibrillar collagen was larger in the TG at 4 days post-operatively (17.53 +/- 6.2% vs 6.79 +/- 1.3%, p = 0.0491), 7 days (31.07 +/- 7.45% vs 12.57 +/- 3.6%, p = 0.0021) and 14 days (30.39 +/- 7.3% vs 19.13 +/- 3.51%, p = 0.0118); the areal fraction of myoblasts and myotubes was larger in the TG at 14 days after surgery (41.66 +/- 2.97% vs 34.83 +/- 3.08%, p = 0.025). Our data suggest that the PUT increases the differentiation of muscular lineage cells, what would favor tissue regeneration. On the other hand, it is also suggested that there is a larger deposition of collagenous fibers, what could mean worse functional performance. However, the percentage of fibers seems to have stabilized at day 7 in TG and kept increasing in CG. Furthermore, the collagen supramolecular organization achieved by the TG is also significant according to the Sirius red staining results. (C) 2008 Elsevier B.V. All rights reserved.