908 resultados para Uncertainty propagation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The citriculture consists in several environmental risks, as weather changes and pests, and also consists in considerable financial risk, mainly due to the period ofreturn on the initial investment. This study was motivated by the need to assess the risks of a business activity such as citriculture. Our objective was to build a stochastic simulation model to achieve the economic and financial analysis of an orange producer in the Midwest region of the state of Sao Paulo, under conditions of uncertainty. The parameters used were the Net Present Value (NPV), the Modified Internal Rate of Return(MIRR), and the Discounted Payback. To evaluate the risk conditions we built a probabilistic model of pseudorandom numbers generated with Monte Carlo method. The results showed that the activity analyzed provides a risk of 42.8% to reach a NPV negative; however, the yield assessed by MIRR was 7.7%, higher than the yield from the reapplication of the positive cash flows. The financial investment pays itself after the fourteenth year of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose using the affinity propagation (AP) clustering algorithm for detecting multiple disjoint shoals, and we present an extension of AP, denoted by STAP, that can be applied to shoals that fusion and fission across time. STAP incorporates into AP a soft temporal constraint that takes cluster dynamics into account, encouraging partitions obtained at successive time steps to be consistent with each other. We explore how STAP performs under different settings of its parameters (strength of the temporal constraint, preferences, and distance metric) by applying the algorithm to simulated sequences of collective coordinated motion. We study the validity of STAP by comparing its results to partitioning of the same data obtained from human observers in a controlled experiment. We observe that, under specific circumstances, AP yields partitions that agree quite closely with the ones made by human observers. We conclude that using the STAP algorithm with appropriate parameter settings is an appealing approach for detecting shoal fusion-fission dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the progress in the field of front propagation in recent years. We survey many physical, biophysical and cross-disciplinary applications, including reduced-variable models of combustion flames, Reid's paradox of rapid forest range expansions, the European colonization of North America during the 19th century, the Neolithic transition in Europe from 13 000 to 5000 years ago, the description of subsistence boundaries, the formation of cultural boundaries, the spread of genetic mutations, theory and experiments on virus infections, models of cancer tumors, etc. Recent theoretical advances are unified in a single framework, encompassing very diverse systems such as those with biased random walks, distributed delays, sequential reaction and dispersion, cohabitation models, age structure and systems with several interacting species. Directions for future progress are outlined

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses basic theoretical strategies used to deal with measurement uncertainties arising from different experimental situations. It attempts to indicate the most appropriate method of obtaining a reliable estimate of the quantity to be evaluated depending on the characteristics of the data available. The theoretical strategies discussed are supported by experimental detail, and the conditions and results have been taken from examples in the field of radionuclide metrology. Special care regarding the correct treatment of covariances is emphasized because of the unreliability of the results obtained if these are neglected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the Bayes factor (BF) or likelihood ratio as a metric to assess the probative value of forensic traces is largely supported by operational standards and recommendations in different forensic disciplines. However, the progress towards more widespread consensus about foundational principles is still fragile as it raises new problems about which views differ. It is not uncommon e.g. to encounter scientists who feel the need to compute the probability distribution of a given expression of evidential value (i.e. a BF), or to place intervals or significance probabilities on such a quantity. The article here presents arguments to show that such views involve a misconception of principles and abuse of language. The conclusion of the discussion is that, in a given case at hand, forensic scientists ought to offer to a court of justice a given single value for the BF, rather than an expression based on a distribution over a range of values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.