896 resultados para Ultra-high-pressure
Resumo:
The selective hydrogenation of acetylene from ethylene rich streams was conducted at high pressure and in the presence of CO over two 1 wt% loaded Pd/TiO2 catalysts with differing dispersions. Although, the more poorly dispersed sample did not result in high acetylene conversion only a small proportion of the total available ethylene was hydrogenated to ethane. The more highly dispersed sample was able to remove acetylene to a level below the detection limit but this was at the expense of significant proportion (ca. 30%) of the available ethylene. Modification of the catalysts by exposure to triphenyl phosphine or diphenyl sulfide and subsequent reduction at 393 K led to improved performance with increased conversion of acetylene and decreased propensity to hydrogenate ethylene resulting in an overall net gain in ethylene. The higher dispersed sample which had been ligand modified provided the best results overall and in particular for the diphenyl sulfide treated sample which was able to completely eliminate acetylene and still obtain a net gain in ethylene. The differences observed are thought to be due to the creation of appropriate active ensembles of Pd atoms which are able to accommodate acetylene but have limited ability to adsorb ethylene. Sub-surface hydrogen formation was suppressed, but not eliminated, by exposure to modifier.
Resumo:
The objective of this research was to determine the surface temperature of a high pressure die casting die during casting conditions. This was achieved by instrumentation of an insert which was placed in the shotplate region of the die. This research overcame the challenge of directly measuring the die surface temperature during a HPDC production casting cycle and shows that this is an effective method to determine the die surface temperature during the casting cycle. The instrumentation results gave a peak and minimum temperature of 500 C and 240 C respectively during steady state running conditions with a molten aluminium casting temperature of 660 C. Stress analysis from the steady state measured temperature of the die surface was calculated through a simple FEA model and the resulting stress uctuation was applied to a fatigue equation for the die material, the predicted number of cycles for cracking to start was found to correlate well with observed die damage.
Resumo:
The densities of five imidazolium-based ionic liquids (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate, [CiC4-Im][BF 4]; 1-butyl-3-methylimidazolium hexafluorophosphate, [CiC 4Im][PF6]; 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}imide, [C1C4Im][Tf 2N]; 1-ethyl-3-methylimidazoliumbis{(trifluoromethyl)sulfonyl}-imide, [C1C2Im][Tf2N]; l-ethyl-3-methylimidazolium ethylsulfate, [C1C2Im][EtSO4]) were measured as a function of temperature from (293 to 415) K and over an extended pressure range from (0.1 to 40) MPa using a vibratingtube densimeter. Knowledge of the variation of the density with temperature and pressure allows access to the mechanical coefficients: thermal expansion coefficient and isothermal compressibility. The effects of the anion and of the length of the alkyl chain on the imidazolium ring on the volumetric properties were particularly examined. The mechanical coefficients were compared with those of common organic solvents, water and liquid NaCl. Finally, a prediction model, based on an "ideal" volumetric behavior of the ILs, is proposed to allow calculation of the molar volume of imidazolium-based ionic liquids as a function of temperature. ©2007 American Chemical Society.
Resumo:
A strain gauge instrumentation trial on a high pressure die casting ‘HPDC’ die was compared to a corresponding simulation model using Magmasoft® casting simulation software at two strain gauge rosette locations. The strains were measured during the casting cycle, from which the von Mises stress was determined and then compared to the simulation model. The von Mises stress from the simulation model correlated well with the findings from the instrumentation trial, showing a difference of 5.5%, ~ 10 MPa for one strain gauge rosette located in an area of low stress gradient. The second rosette was in a region of steep stress gradient, which resulted in a difference of up to 40%, ~40 MPa between the simulation and instrumentation results. Factors such as additional loading from die closure force or metal injection pressure which are not modelled by Magmasoft® were seen to have very little influence on the stress in the die, less than 7%.
Resumo:
Spherical, ultra-high specific surface area monodisperse polymer particles with diameters in the low micrometer size range are disclosed for the first time. The polymer particles are able to sorb significant levels of both hydrocarbon solvents and water, acting in effect as amphipathic micro-sponges. Exciting possibilities for exploitation of the particles in chromatography, diagnostics, sensors, delivery vehicles and catalysis are suggested.
Resumo:
This works follows a publication of our group in J. Chem. Eng. Data2007, 52, 2204–2211 presenting high temperature and pressure density data for five imidazolium-based ionic liquids. At this period, very few ionic liquid density data were available in the literature, especially at high pressure, and the uncertainty of published results was calculated with respect to the literature data available for three of the five ionic liquids studied. Since 2007, the ionic liquid density databank has largely increased. In this work, a comparison of our published data in J. Chem. Eng. Data2007, 52, 2204–2211, with more than 1800 high pressure data coming from the literature up to December 2011 is presented to assess the uncertainty of our published values. The claimed uncertainty is close to 0.31 % for all IL density data sets except in the case of the [C1C2Im][EtSO4], where the uncertainty is up to 1.1 %. Reported data in J. Chem. Eng. Data2007, 52, 2204–2211, for this particular ionic liquid cannot be used as a reference. For this ionic liquid, new density measurements of the same sample batch have been remeasured by using the same experimental technique, and new experimental data presented herein are clearly higher than our previous published results. A 1H NMR analysis of the sample has confirmed hydrolysis of the ethylsulfate anion to ethanol and hydrogenate anion which explains the differences observed between our density data and the literature.
Resumo:
We report the magnetic and electrical characteristics of polycrystalline FeTiO3 synthesized at high pressure that is isostructural with acentric LiNbO3 (LBO). Piezoresponse force microscopy, optical second harmonic generation, and magnetometry demonstrate ferroelectricity at and below room temperature and weak ferromagnetism below ~120??K. These results validate symmetry-based criteria and first-principles calculations of the coexistence of ferroelectricity and weak ferromagnetism in a series of transition metal titanates crystallizing in the LBO structure.
Resumo:
A combined experimental-computational study on the CO absorption on 1-butyl-3-methylimidazolium hexafluophosphate, 1-ethyl-3-methylimidazolium bis[trifluoromethylsulfonyl]imide, and 1-butyl-3-methylimidazolium bis[trifluoromethylsulfonyl]imide ionic liquids is reported. The reported results allowed to infer a detailed nanoscopic vision of the absorption phenomena as a function of pressure and temperature. Absorption isotherms were measured at 318 and 338K for pressures up to 20MPa for ultrapure samples using a state-of-the-art magnetic suspension densimeter, for which measurement procedures are developed. A remarkable swelling effect upon CO absorption was observed for pressures higher than 10MPa, which was corrected using a method based on experimental volumetric data. The experimental data reported in this work are in good agreement with available literature isotherms. Soave-Redlich-Kwong and Peng-Robinson equations of state coupled with bi-parametric van der Waals mixing rule were used for successful correlations of experimental high pressure absorption data. Molecular dynamics results allowed to infer structural, energetic and dynamic properties of the studied CO+ionic liquids mixed fluids, showing the relevant role of the strength of anion-cation interactions on fluid volumetric properties and CO absorption. © 2012 Elsevier B.V.
Resumo:
The potential that laser based particle accelerators offer to solve sizing and cost issues arising with conventional proton therapy has generated great interest in the understanding and development of laser ion acceleration, and in investigating the radiobiological effects induced by laser accelerated ions. Laser-driven ions are produced in bursts of ultra-short duration resulting in ultra-high dose rates, and an investigation at Queen's University Belfast was carried out to investigate this virtually unexplored regime of cell rdaiobiology. This employed the TARANIS terawatt laser producing protons in the MeV range for proton irradiation, with dose rates exceeding 10 Gys on a single exposure. A clonogenic assay was implemented to analyse the biological effect of proton irradiation on V79 cells, which, when compared to data obtained with the same cell line irradiated with conventionally accelerated protons, was found to show no significant difference. A Relative Biological effectiveness of 1.4±0.2 at 10 % Survival Fraction was estimated from a comparison with a 225 kVp X-ray source. © 2013 SPIE.
Resumo:
An endocrine disruptor (ED) is an exogenous compound that interferes with the body's endocrine system. Exposure to EDs may result in adverse health effects such as infertility and cancer. EDs are composed of a vast group of chemicals including compounds of natural origin such as phytoestrogens or mycotoxins and a wide range of man-made chemicals such as pesticides. Synthetic compounds may find their way into the food chain where a number of them can biomagnify. Additionally, processing activities and food contact materials may add further to the already existing pool of food contaminants. Thus, our diet is considered to be one of the main exposure routes to EDs. Some precautionary legislation has already been introduced to control production and/or application of some persistent organic pollutants with ED characteristics. However, newly emerging EDs with bioaccumulative properties have recently been reported to appear at lower tiers of the food chain but have not been monitored at the grander scale. Milk and dairy products are a major component of our diet, thus it is important to monitor them for EDs. However, most methods developed to date are devoted to one group of compounds at a time. The UHPLC-MS/MS method described here has been validated according to EC decision 2002/657/EC and allows simultaneous extraction, detection, quantitation and confirmation of 19 EDs in milk. The method calibration range is between 0.50 and 20.0 μg kg with coefficients of determination above 0.99 for all analytes. Precision varied from 4.7% to 23.4% in repeatability and reproducibility studies. Established CCα and CCβ values (0.11-0.67 μg kg) facilitate fast, reliable, quantitative and confirmatory analysis of sub μg kg levels of a range of EDs in milk.