867 resultados para Two diagnostic tests
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
In Brazil there are few studies on the occurrence of the feline immunodeficiency virus (FIV) infection and its subtypes, which are essential for the development of vaccines and new diagnostic tests. The present study investigated the occurrence of the FIV infection between 2010 and 2011 in domestic cats submitted to medical attendance in the city of Pelotas and nearby area. Total blood samples of seventy cats, suspected (28) or not (42) of infection by FIV were analyzed by nested PCR in order to perform a diagnosis. The results pointed to a FIV infection frequency of 15.7% (11/70) and the analysis of the risk factors related to infection (sex, age and clinical condition) evidenced a greater occurrence in cats up to 10 years of age with chronic and recurrent infections. Eight samples found positive by nested PCR were submitted to DNA sequencing indicating that only the subtype B was detected in the studied region.
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
The main objective of this study was to analyze the reliability of blood lactate concentration ([La]), oxygen uptake (VO2) and heart rate (FC) in an intermittent protoco, performed at 95%VO2max with passive or active recovery in untrained subjects. Participated of this study, active healthy males with 20 to 25 years, which were doing aerobic exercises witha weekly frequency of 3 sessions at least. The individulas performed, in different days, the following protocols in a cyclergometer: 1) An incremental test until exhaustion to determine maximal oxygen uptake (VO2max) and the intensity at VO2max; b) Two transitions at 95%VO2max for the determination of the VO2 kinetics parameters and; c) Two intermittent tests until exhaustion, with repetitions at 95% IVO2max and with durantion defined as being half of the duration of the slow component. The duration of the recovery was half of the duration of the effort (effort:pause of 2:1). This test was performed with passive (GP) and active recovery (GA). The VO2 and FC were measured continulously in both tests. Blood collections were performed for the determination of the [La]. There was significant correlação in both groups for VO2 (ATIVA - 0.94, PASSIVA - 0.75), [La] (ATIVA - 0.83, PASSIVA - 0.90) and FC (0.93) only for the passive group. Thus, it can be concluded that the cardiorrespiratory and metabolic responses present good realiability in an intermittent exercise with active or passive recovery
Resumo:
Frying is a widely used method of preparing food, because it is a very fast and convenient process, and because it provides specific characteristics of color, flavor, odor, and texture, besides having great consumer acceptance. Therefore, the interest in the physiological effects that oils heated at high temperatures can cause to the human body arises. The aim of this work was to analyze the levels of frying used oil alteration in different kinds of foods served at the university restaurant at “Instituto de Biociências, Letras e Ciências Exatas” (IBILCE), in São José do Rio Preto-SP. In addition, it aims to make the restaurant aware of the good ways to fry and the commitment of providing good quality food to students and professionals of the Institute. With this purpose, determination of total polar compounds, conjugated dienoic acids, peroxide value, and fatty acid profile were analyzed. Two rapid tests were also used: 3M Fat Monitor and Oil Test kit. The results were compared with limits recommended for the disposal of oils and fats used in frying by the Brazilian Health Surveillance Agency (ANVISA), by other countries, and by other researches. Thus, it was concluded that the university restaurant provides the consumers with fried food of good quality, since none of the analyses showed results above recommended, although there is a need of improvement in the quality control of the oil used, in order to avoid unnecessary costs to the university restaurant.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
This paper presents two diagnostic methods for the online detection of broken bars in induction motors with squirrel-cage type rotors. The wavelet representation of a function is a new technique. Wavelet transform of a function is the improved version of Fourier transform. Fourier transform is a powerful tool for analyzing the components of a stationary signal. But it is failed for analyzing the non-stationary signal whereas wavelet transform allows the components of a non-stationary signal to be analyzed. In this paper, our main goal is to find out the advantages of wavelet transform compared to Fourier transform in rotor failure diagnosis of induction motors.
Resumo:
To assess the pain intensity of patients administered midazolam and fentanyl citrate before undergoing transrectal ultrasound-guided prostate biopsy. This was a study in patients with different indications for prostate biopsy in whom 5 mg of midazolam and 50 µg of fentanyl citrate was administered intravenously 3 minutes before the procedure. After biopsy, pain was assessed by use of a visual analogue scale (VAS) in three stages: VAS 1, during probe introduction; VAS 2, during needle penetration into prostate tissue; and VAS 3, in the weeks following the exam. Pain intensity at these different times was tested with stratification by age, race, education, prostate volume, rebiopsy, and anxiety before biopsy. Pain was ranked according to the following scores: 0 (no pain), 1-3 (mild pain), 4-7 (moderate pain), and 8-10 (severe pain). Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon two-tailed tests with a significance of 5%. Pain intensity was not influenced by any risk factors. The mean VAS 1 score was 1.95±1.98, the mean VAS 2 score was 2.73±2.55, and the mean VAS 3 score was 0.3±0.9, showing greater pain at the time of needle penetration than in other situations (VAS 2>VAS 1>VAS 3, p=0.0013, p=0.0001, respectively). Seventy-five percent of patients reported a VAS pain scale of less than 3.1 or mild pain. Intravenous sedation and analgesia with midazolam and fentanyl citrate is a good method for reducing pain caused by prostate biopsy, even during probe insertion.