924 resultados para Tricuspid valve
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.
Resumo:
BACKGROUND Anticoagulation is required during transcatheter aortic valve replacement (TAVR) procedures. Although an optimal regimen has not been determined, heparin is mainly used. Direct thrombin inhibition with bivalirudin may be an effective alternative to heparin as the procedural anticoagulant agent in this setting. OBJECTIVES The goal of this study was to determine whether bivalirudin offers an alternative to heparin as the procedural anticoagulant agent in patients undergoing TAVR. METHODS A total of 802 patients with aortic stenosis were randomized to undergo transfemoral TAVR with bivalirudin versus unfractionated heparin during the procedure. The 2 primary endpoints were major bleeding within 48 h or before hospital discharge (whichever occurred first) and 30-day net adverse clinical events, defined as the combination of major adverse cardiovascular events (all-cause mortality, myocardial infarction, or stroke) and major bleeding. RESULTS Anticoagulation with bivalirudin versus heparin did not meet superiority because it did not result in significantly lower rates of major bleeding at 48 h (6.9% vs. 9.0%; relative risk: 0.77; 95% confidence interval [CI]: 0.48 to 1.23; p = 0.27) or net adverse cardiovascular events at 30 days (14.4% vs. 16.1%; relative risk: 0.89; 95% CI: 0.64 to 1.24; risk difference: -1.72; 95% CI: -6.70 to 3.25; p = 0.50); regarding the latter, the prespecified noninferiority hypothesis was met (pnoninferiority < 0.01). Rates of major adverse cardiovascular events at 48 h were not significantly different (3.5% vs. 4.8%; relative risk: 0.73; 95% CI: 0.37 to 1.43; p = 0.35). At 48 h, the bivalirudin group had significantly fewer myocardial infarctions but more acute kidney injury events than the heparin group; at 30 days, these differences were no longer significant. CONCLUSIONS In this randomized trial of TAVR procedural pharmacotherapy, bivalirudin did not reduce rates of major bleeding at 48 h or net adverse cardiovascular events within 30 days compared with heparin. Although superiority was not shown, the noninferiority hypothesis was met with respect to the latter factor. Given the lower cost, heparin should remain the standard of care, and bivalirudin can be an alternative anticoagulant option in patients unable to receive heparin in TAVR. (International, Multi-center, Open-label, Randomized Controlled Trial in Patients Undergoing TAVR to Determine the Treatment Effect [Both Safety and Efficacy] of Using Bivalirudin Instead of UFH [BRAVO-2/3]; NCT01651780).
Resumo:
Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.
Resumo:
BACKGROUND Biomarkers of myocardial injury increase frequently during transcatheter aortic valve implantation (TAVI). The impact of postprocedural cardiac troponin (cTn) elevation on short-term outcomes remains controversial, and the association with long-term prognosis is unknown. METHODS AND RESULTS We evaluated 577 consecutive patients with severe aortic stenosis treated with TAVI between 2007 and 2012. Myocardial injury, defined according to the Valve Academic Research Consortium (VARC)-2 as post-TAVI cardiac troponin T (cTnT) >15× the upper limit of normal, occurred in 338 patients (58.1%). In multivariate analyses, myocardial injury was associated with higher risk of all-cause mortality at 30 days (adjusted hazard ratio [HR], 8.77; 95% CI, 2.07-37.12; P=0.003) and remained a significant predictor at 2 years (adjusted HR, 1.98; 95% CI, 1.36-2.88; P<0.001). Higher cTnT cutoffs did not add incremental predictive value compared with the VARC-2-defined cutoff. Whereas myocardial injury occurred more frequently in patients with versus without coronary artery disease (CAD), the relative impact of cTnT elevation on 2-year mortality did not differ between patients without CAD (adjusted HR, 2.59; 95% CI, 1.27-5.26; P=0.009) and those with CAD (adjusted HR, 1.71; 95% CI, 1.10-2.65; P=0.018; P for interaction=0.24). Mortality rates at 2 years were lowest in patients without CAD and no myocardial injury (11.6%) and highest in patients with complex CAD (SYNTAX score >22) and myocardial injury (41.1%). CONCLUSIONS VARC-2-defined cTnT elevation emerged as a strong, independent predictor of 30-day mortality and remained a modest, but significant, predictor throughout 2 years post-TAVI. The prognostic value of cTnT elevation was modified by the presence and complexity of underlying CAD with highest mortality risk observed in patients combining SYNTAX score >22 and evidence of myocardial injury.
Resumo:
The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry (PIV). Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.
Resumo:
The purpose of this study was to elucidate the relationship between mitral valve prolapse and stroke. A population-based historical cohort investigation was conducted among residents of Olmsted County, Minnesota who had an initial echocardiographic diagnosis of mitral valve prolapse from 1975 through 1989. This cohort (N = 1085) was followed for stroke outcomes using the resources of an operational medical record linkage system. There was an overall two-fold increase in the incidence of stroke among individuals with mitral valve prolapse relative to a standard population (standardized morbidity ratio = 2.12, 95% confidence limits = 1.33-3.21). When the data were partitioned by duration of follow-up from the diagnosis of mitral valve prolapse, or by the calendar years at echocardiographic diagnosis, respectively, the association between mitral valve prolapse and stroke was not modified. Mitral valve prolapse subjects 85 years and older were at highest increased risk of developing strokes relative to the general population (standardized morbidity ratio = 5.47, 95% confidence limits = 2.20-11.24). Coronary heart disease, atrial fibrillation, diabetes mellitus and hypertension, were unlikely to have confounded the association between mitral valve prolapse and stroke.^ The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 15 to 64 years, given survival to 15.2 years of follow-up, was 4.0%. The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 65 to 74 years, given survival to 11.2 years of follow-up, was 13.2%. The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 75 years and older, given survival to 6.7 years of follow-up, was 30.6%.^ Among individuals with mitral valve prolapse, age, diabetes, and atrial fibrillation were associated with an increased risk of stroke. Atrial fibrillation was associated with a four-fold rate of stroke and diabetes associated with a seven-fold rate of stroke.^ Findings from this research support the hypothesis that mitral valvular heart prolapse is linked with a stroke sequela. ^
Resumo:
Heart valve prostheses are used to replace native heart valves which that are damaged because of congenital diseases or due to ageing. Biological prostheses made of bovine pericardium are similar to native valves and do not require any anticoagulation treatment, but are less durable than mechanical prostheses and usually fail by tearing. Researches are oriented in improving the resistance and durability of biological heart valve prostheses in order to increase their life expectancy. To understand the mechanical behaviour of bovine pericardium and relate it to its microstructure (mainly collagen fibres concentration and orientation) uniaxial tensile tests have been performed on a model material made of collagen fibres. Small Angle Light Scattering (SALS) has been also used to characterize the microstructure without damaging the material. Results with the model material allowed us to obtain the orientation of the fibres, relating the microstructure to mechanical performance