984 resultados para Thoracic Aorta


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Jeune asphyxiating thoracic dystrophy (JATD) is a rare, often lethal, recessively inherited chondrodysplasia characterised by shortened ribs and long bones, sometimes accompanied by polydactyly, and renal, liver and retinal disease. Mutations in intraflagellar transport (IFT) genes cause JATD, including the IFT dynein-2 motor subunit gene DYNC2H1. Genetic heterogeneity and the large DYNC2H1 gene size have hindered JATD genetic diagnosis. AIMS AND METHODS: To determine the contribution to JATD we screened DYNC2H1 in 71 JATD patients JATD patients combining SNP mapping, Sanger sequencing and exome sequencing. RESULTS AND CONCLUSIONS: We detected 34 DYNC2H1 mutations in 29/71 (41%) patients from 19/57 families (33%), showing it as a major cause of JATD especially in Northern European patients. This included 13 early protein termination mutations (nonsense/frameshift, deletion, splice site) but no patients carried these in combination, suggesting the human phenotype is at least partly hypomorphic. In addition, 21 missense mutations were distributed across DYNC2H1 and these showed some clustering to functional domains, especially the ATP motor domain. DYNC2H1 patients largely lacked significant extra-skeletal involvement, demonstrating an important genotype-phenotype correlation in JATD. Significant variability exists in the course and severity of the thoracic phenotype, both between affected siblings with identical DYNC2H1 alleles and among individuals with different alleles, which suggests the DYNC2H1 phenotype might be subject to modifier alleles, non-genetic or epigenetic factors. Assessment of fibroblasts from patients showed accumulation of anterograde IFT proteins in the ciliary tips, confirming defects similar to patients with other retrograde IFT machinery mutations, which may be of undervalued potential for diagnostic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Control of hemorrhage in patients with active bleeding from rupture of the aortic arch is difficult, because of the location of the bleeding and the impossibility of cross-clamping the aorta without interfering with cerebral perfusion. A precise and swift plan of management helped us salvage some patients and prompted us to review our experience. METHODS: Six patients with active bleeding of the aortic arch in the mediastinum and pericardial cavity (5 patients) or left pleural cavity (1 patient), treated between 1992 and 1996, were reviewed. Bleeding was reduced by keeping the mediastinum under local tension (3 patients) or by applying compression on the bleeding site (2 patients), or both (1 patient) while circulatory support, retransfusion of aspirated blood, and hypothermia were established. The diseased aortic arch was replaced during deep hypothermic circulatory arrest, which ranged from 25 to 40 minutes. In 3 patients, the brain was further protected by retrograde (2 patients) or antegrade (1 patient) cerebral perfusion. RESULTS: Hemorrhage from the aortic arch was controlled in all patients. Two patients died postoperatively, one of respiratory failure and the other of abdominal sepsis. Recovery of neurologic function was assessed and complete in all patients. The 4 survivors are well 8 to 49 months after operation. CONCLUSIONS: An approach relying on local tamponade to reduce bleeding, rapid establishment of circulatory support and hypothermia, retransfusion of aspirated blood, and swift repair of the aortic arch under circulatory arrest allows salvage of patients with active bleeding from an aortic arch rupture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resection of lung metastases from colorectal cancer (CRC) is increasingly performed with a curative intent. This strategy was made possible in the 1990s by the development of new chemotherapeutic approaches, improved surgical techniques and better imaging modalities. However, evidence-based data showing clinical benefits of lung metastasectomy in this setting are nonexistent, and there are no prospective randomized trials to support the routine performance of these procedures for stage IV CRC. Current evidence suggests that resection of pulmonary metastases in combination with new cytotoxic agents, such as oxaliplatin, irinotecan and bevacizumab, may result in prolonged survival for many, and cure for a small minority of CRC patients who experienced tumor spread beyond the limits of the abdomen. This review focuses on the results of surgical management of CRC patients with lung metastases: we report the outcome of published series according to the presence or the absence of liver metastasis (and hepatic resection) prior to lung resection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi retrospectiu de pacients tractats d'aneurisma d'aorta abdominal, mitjangant reparació endovascular. Període reclutament: 2006 a 201,2. Van ser dividits en dos grups depenen de les característiques anatómiques del coll aórtic proximal, considerant si eren o no favorables pel tractament endovascular. L'objectiu de l'estudi és avaluar els resultats immediats del tractament en funció de la morfologia del coll aórtic. 95 pacients van ser inclosos (62 favorable, 33 hostil). S'analitzen els motius per considerar el coll com hostil, aixícom els resultats d'aquestes técniques. Conclusió: el tractament endovascular és una técriica válida per aquest tipus pacient amb colls aórtics no favorables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Prevalence of abdominal aortic aneurysms (AAA) is not exactly known among patients with coronary artery disease (CAD) who are considered for surgical revascularisation. We evaluated the value of screening AAA among coronary patients admitted in our cardiovascular surgery unit. METHODS: Over a 24-month period, an abdominal echography was proposed to male patients aged 60 or more while hospitalised for surgical coronary revascularisation. Patients with previous investigation of the aorta were excluded. The aorta was considered aneurysmal when the anterior-posterior diameter was of 30 mm or more. RESULTS: Three hundred and ninety-five consecutive patients all accepted a proposed abdominal echographic screening for AAA. Forty unsuspected AAA were detected (10.1%). The mean diameter was 38.9 +/- 1.3 mm. Four AAA were larger than 50 mm and considered for surgery after the CABG procedure. Surveillance was proposed to the other 36, especially the 10 patients with an AAA larger than 40 mm. Patients with AAA were significantly older than those without AAA (71.3 +/- 0.8 vs. 69.4 +/- 0.3 years, P<0.05). Smoking history (P<0.05) and hypertension (P<0.05) were also associated more frequently with AAA. More than 16% of the patients being smokers and suffering hypertension presented with unsuspected AAA. CONCLUSIONS: In-hospital screening of AAA is very efficient among patients with coronary artery disease. Therefore, patients with CAD may be considered for routine AAA screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 9-month-old girl presented with life-threatening acute respiratory failure 1 week after the surgical correction of a double aortic arch, which was due to a severe bulging of the pars membranacea into the lumen of the trachea that produced a complete obstruction of the lower trachea. Under cardiopulmonary bypass, a Y-shaped posterior biodegradable splint was placed behind the trachea and sutured to the posterior trachea, and a simultaneous right aortic arch aortopexy was performed. Thereafter, the child recovered normal respiratory function. Follow-up bronchoscopy showed a posterior dip at the splint level and an asymptomatic persistent posterior compression of the right main bronchus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chylothorax is an uncommon disorder with respiratory, nutritional and immunological manifestations. Surgical management is indicated in case of recurrence or failure after conservative treatment. We report our experience with video-assisted right-sided supradiaphragmatic thoracic duct ligation for non-traumatic, non-postoperative persistent or recurrent chylothorax. PATIENTS AND METHODS: The medical records of six patients operated at our institution between 1999 and 2004 were retrospectively reviewed. A right-sided chylothorax was found in four patients, a left-sided in one, and a bilateral in one. Three patients developed chylothorax after chemotherapy and chest irradiation for malignant diseases (lymphoma in two patients and breast cancer in one), one in the context of lymphangioleiomyomatosis, one due to a non-diagnosed lymphoma, and one after heart transplantation. RESULTS: The mean operative time was 102 min, with an average length of hospital stay of 14 days. Persistent cessation of chylous effusion within 7 days after surgery was observed in 5/6 patients without recurrence during a mean follow-up time of 41 months. One patient with undiagnosed mediastinal lymphoma required re-operation and thoracic duct ligation on day 8 by right-sided thoracotomy due to persistent chylothorax. No 30-day mortality was recorded. Two patients presented postoperative complications including respiratory insufficiency requiring mechanical ventilation in one, and chylous ascites development requiring peritoneo-venous LeVeen shunting in one patient. CONCLUSIONS: Recurrent or persistent non-traumatic chylothorax may be successfully treated by video-assisted right supradiaphragmatic thoracic duct ligation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary rib involvement accounts for 16% of paediatric Ewing sarcoma (ES). Neo-adjuvant chemotherapy and surgical tumor resection may leave large thoracic wall defects requiring complex reconstruction in a growing individual. We report our experience in three children aged 3, 10, and 12 years, in whom single-stage resection and reconstruction were performed using a Gore-Tex Dualmesh patch, covered by a latissimus dorsi rotation flap harvested in continuity with the thoracolumbar fascia. The youngest patient also had a vertical expandable prosthetic titanium rib (VEPTR) anchored to help prevent subsequent scoliosis throughout growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assess outcome of patients with descending thoracic aortic aneurysms complicated by aortobronchial and aortoesophageal fistulae in comparison to patients undergoing repair of aortic aneurysms without fistulae. METHODS: In a consecutive series of 145 patients (age 60 +/- 12 years) with repair of descending thoracic and thoracoabdominal aortic aneurysms, 11 patients (8%; age 63 +/- 9; NS) primarily presented for hematemesis and/or hemoptysis. In 8/11 patients (73%) an aortobronchial fistula was identified, and 3/11 patients (27%) suffered from an aortoesophageal fistula. Five of 11 patients (45%) had undergone previous aortic surgery in the same region. RESULTS: Extent of aortic segments (range 1-8) replaced was 3.1 +/- 1.4 for all versus 2.6 +/- 0.9 for fistulae (NS). Aortic cross clamp time was 38 +/- 22 min for all versus 45 +/- 15 min for fistulae (NS). Mortality at 30 days was 18/145 (12%) for all versus 16/134 (12%) without fistulae versus 2/11 (18%) with fistulae (NS). Paraparesis and or paraplegia was observed in 11/145 (8%) for all versus 10/134 (7%) without fistulae versus 1/11 (9%) for cases with fistulae (NS). Nine additional patients died after hospital discharge, seven without fistulae and two with fistulae (days 80, and 120) bringing the 1-year mortality up to 23/134 (17%) without fistulae versus 4/11 (36%) with fistulae (NS). Further analysis shows that the 1-year mortality accounts for 1/8 patients (13%) with aorto-bronchial fistulae versus to 3/3 patients (100%) with aorto-esophageal fistulae (esophageal versus bronchial fistula: P = 0.018; esophageal versus no fistula: P = 0.006). CONCLUSIONS: Outcome of patients suffering from descending thoracic aortic aneurysms complicated by aorto-bronchial fistulae can be similar to that without fistulae, whereas for cases complicated by aorto-esophageal fistulae the prognosis seems to remain poor even after successful hospital discharge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.