946 resultados para TO-NOISE RATIO


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel cantilever pressure sensor was developed in the Department of Physics at the University of Turku in order to solve the sensitivity problems which are encountered when condenser microphones are used in photoacoustic spectroscopy. The cantilever pressure sensor, combined with a laser interferometer for the measurement of the cantilever movements, proved to be highly sensitive. The original aim of this work was to integrate the sensor in a photoacoustic gas detector working in a differential measurement scheme. The integration was made successfully into three prototypes. In addition, the cantilever was also integrated in the photoacoustic FTIR measurement schemes of gas-, liquid-, and solid-phase samples. A theoretical model for the signal generation in each measurement scheme was created and the optimal celldesign discussed. The sensitivity and selectivity of the differential method were evaluated when a blackbody radiator and a mechanical chopper were used with CO2, CH4, CO, and C2H4 gases. The detection limits were in the sub-ppm level for all four gases with only a 1.3 second integration time and the cross interference was well below one percent for all gas combinations other than those between hydrocarbons. Sensitivity with other infrared sources was compared using ethylene as an example gas. In the comparison of sensitivity with different infrared sources the electrically modulated blackbody radiator gave a 35 times higher and the CO2-laser a 100 times lower detection limit than the blackbody radiator with a mechanical chopper. As a conclusion, the differential system is well suited to rapid single gas measurements. Gas-phase photoacoustic FTIR spectroscopy gives the best performance, when several components have to be analyzed simultaneously from multicomponent samples. Multicomponent measurements were demonstrated with a sample that contained different concentrations of CO2, H2O, CO, and four different hydrocarbons. It required an approximately 10 times longer measurement time to achieve the same detection limit for a single gas as with the differential system. The properties of the photoacoustic FTIR spectroscopy were also compared to conventional transmission FTIR spectroscopy by simulations. Solid- and liquid-phase photoacoustic FTIR spectroscopy has several advantages compared to other techniques and therefore it also has a great variety of applications. A comparison of the signal-to-noise ratio between photoacoustic cells with a cantilever microphone and a condenser microphone was done with standard carbon black, polyethene, and sunflower oil samples. The cell with the cantilever microphone proved to have a 5-10 times higher signal-to-noise ratio than the reference detector, depending on the sample. Cantilever enhanced photoacoustics will be an effective tool for gas detection and analysis of solid- and liquid-phase samples. The preliminary prototypes gave good results in all three measurement schemes that were studied. According to simulations, there are possibilities for further enhancement of the sensitivity, as well as other properties, of each system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of analytical procedures based on multivariate calibration models has been limited in several areas due to requirements of validation and certification of the model. Procedures for validation are presented based on the determination of figures of merit, such as precision (mean, repeatability, intermediate), accuracy, sensitivity, analytical sensitivity, selectivity, signal-to-noise ratio and confidence intervals for PLS models. An example is discussed of a model for polymorphic purity control of carbamazepine by NIR diffuse reflectance spectroscopy. The results show that multivariate calibration models can be validated to fulfill the requirements imposed by industry and standardization agencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The validation of an analytical procedure must be certified through the determination of parameters known as figures of merit. For first order data, the acuracy, precision, robustness and bias is similar to the methods of univariate calibration. Linearity, sensitivity, signal to noise ratio, adjustment, selectivity and confidence intervals need different approaches, specific for multivariate data. Selectivity and signal to noise ratio are more critical and they only can be estimated by means of the calculation of the net analyte signal. In second order calibration, some differentes approaches are necessary due to data structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Steady-State Free Precession (SSFP) sequence has been widely used in low-field and low-resolution imaging NMR experiments to increase the signal-to-noise ratio (s/n) of the signals. Here, we analyzed the Scrambled Steady State - SSS and Unscrambled Steady State - USS sequences to suppress phase anomalies and sidebands of the 13C NMR spectrum acquired in the SSFP regime. The results showed that the application of the USS sequence allowed a uniform distribution of the time interval between pulses (Tp), in the established time range, allowing a greater suppression of phase anomalies and sidebands, when compared with the SSS sequence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In many industrial applications, such as the printing and coatings industry, wetting of porous materials by liquids includes not only imbibition and permeation into the bulk but also surface spreading and evaporation. By understanding these phenomena, valuable information can be obtained for improved process control, runnability and printability, in which liquid penetration and subsequent drying play important quality and economic roles. Knowledge of the position of the wetting front and the distribution/degree of pore filling within the structure is crucial in describing the transport phenomena involved. Although exemplifying paper as a porous medium in this work, the generalisation to dynamic liquid transfer onto a surface, including permeation and imbibition into porous media, is of importance to many industrial and naturally occurring environmental processes. This thesis explains the phenomena in the field of heatset web offset printing but the content and the analyses are applicable in many other printing methods and also other technologies where water/moisture monitoring is crucial in order to have a stable process and achieve high quality end products. The use of near-infrared technology to study the water and moisture response of porous pigmented structures is presented. The use of sensitive surface chemical and structural analysis, as well as the internal structure investigation of a porous structure, to inspect liquid wetting and distribution, complements the information obtained by spectroscopic techniques. Strong emphasis has been put on the scale of measurement, to filter irrelevant information and to understand the relationship between interactions involved. The near-infrared spectroscopic technique, presented here, samples directly the changes in signal absorbance and its variation in the process at multiple locations in a print production line. The in-line non-contact measurements are facilitated by using several diffuse reflectance probes, giving the absolute water/moisture content from a defined position in the dynamic process in real-time. The nearinfrared measurement data illustrate the changes in moisture content as the paper is passing through the printing nips and dryer, respectively, and the analysis of the mechanisms involved highlight the roles of the contacting surfaces and the relative liquid carrier properties of both non-image and printed image areas. The thesis includes laboratory studies on wetting of porous media in the form of coated paper and compressed pigment tablets by mono-, dual-, and multi-component liquids, and paper water/moisture content analysis in both offline and online conditions, thus also enabling direct sampling of temporal water/moisture profiles from multiple locations. One main focus in this thesis was to establish a measurement system which is able to monitor rapid changes in moisture content of paper. The study suggests that near-infrared diffuse reflectance spectroscopy can be used as a moisture sensitive system and to provide accurate online qualitative indicators, but, also, when accurately calibrated, can provide quantification of water/moisture levels, its distribution and dynamic liquid transfer. Due to the high sensitivity, samples can be measured with excellent reproducibility and good signal to noise ratio. Another focus of this thesis was on the evolution of the moisture content, i.e. changes in moisture content referred to (re)wetting, and liquid distribution during printing of coated paper. The study confirmed different wetting phases together with the factors affecting each phase both for a single droplet and a liquid film applied on a porous substrate. For a single droplet, initial capillary driven imbibition is followed by equilibrium pore filling and liquid retreat by evaporation. In the case of a liquid film applied on paper, the controlling factors defining the transportation were concluded to be the applied liquid volume in relation to surface roughness, capillarity and permeability of the coating giving the liquid uptake capacity. The printing trials confirmed moisture gradients in the printed sheet depending on process parameters such as speed, fountain solution dosage and drying conditions as well as the printed layout itself. Uneven moisture distribution in the printed sheet was identified to be one of the sources for waving appearance and the magnitude of waving was influenced by the drying conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates defect detection methodologies for rolling element bearings through vibration analysis. Specifically, the utility of a new signal processing scheme combining the High Frequency Resonance Technique (HFRT) and Adaptive Line Enhancer (ALE) is investigated. The accelerometer is used to acquire data for this analysis, and experimental results have been obtained for outer race defects. Results show the potential effectiveness of the signal processing technique to determine both the severity and location of a defect. The HFRT utilizes the fact that much of the energy resulting from a defect impact manifests itself in the higher resonant frequencies of a system. Demodulation of these frequency bands through use of the envelope technique is then employed to gain further insight into the nature of the defect while further increasing the signal to noise ratio. If periodic, the defect frequency is then present in the spectra of the enveloped signal. The ALE is used to enhance the envelope spectrum by reducing the broadband noise. It provides an enhanced envelope spectrum with clear peaks at the harmonics of a characteristic defect frequency. It is implemented by using a delayed version of the signal and the signal itself to decorrelate the wideband noise. This noise is then rejected by the adaptive filter that is based upon the periodic information in the signal. Results have been obtained for outer race defects. They show the effectiveness of the methodology to determine both the severity and location of a defect. In two instances, a linear relationship between signal characteristics and defect size is indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interferometer for low resolution portable Fourier Transform middle infrared spectrometer was developed and studied experimentally. The final aim was a concept for a commercial prototype. Because of the portability, the interferometer should be compact sized and insensitive to the external temperature variations and mechanical vibrations. To minimise the size and manufacturing costs, Michelson interferometer based on plane mirrors and porch swing bearing was selected and no dynamic alignment system was applied. The driving motor was a linear voice coil actuator to avoid mechanical contact of the moving parts. The driving capability for low mirror driving velocities required by the photoacoustic detectors was studied. In total, four versions of such an interferometer were built and experimentally studied. The thermal stability during the external temperature variations and the alignment stability over the mirror travel were measured using the modulation depth of the wide diameter laser beam. Method for estimating the mirror tilt angle from the modulation depth was developed to take account the effect from the non-uniform intensity distribution of the laser beam. The spectrometer stability was finally studied also using the infrared radiation. The latest interferometer was assembled for the middle infrared spectrometer with spectral range from 750 cm−1 to 4500 cm−1. The interferometer size was (197 × 95 × 79) mm3 with the beam diameter of 25 mm. The alignment stability as the change of the tilt angle over the mirror travel of 3 mm was 5 μrad, which decreases the modulation depth only about 0.7 percent in infrared at 3000 cm−1. During the temperature raise, the modulation depth at 3000 cm−1 changed about 1 . . . 2 percentage units per Celsius over short term and even less than 0.2 percentage units per Celsius over the total temperature raise of 30 °C. The unapodised spectral resolution was 4 cm−1 limited by the aperture size. The best achieved signal to noise ratio was about 38 000:1 with commercially available DLaTGS detector. Although the vibration sensitivity requires still improving, the interferometer performed, as a whole, very well and could be further developed to conform all the requirements of the portable and stable spectrometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An interesting fact about language cognition is that stimulation involving incongruence in the merge operation between verb and complement has often been related to a negative event-related potential (ERP) of augmented amplitude and latency of ca. 400 ms - the N400. Using an automatic ERP latency and amplitude estimator to facilitate the recognition of waves with a low signal-to-noise ratio, the objective of the present study was to study the N400 statistically in 24 volunteers. Stimulation consisted of 80 experimental sentences (40 congruous and 40 incongruous), generated in Brazilian Portuguese, involving two distinct local verb-argument combinations (nominal object and pronominal object series). For each volunteer, the EEG was simultaneously acquired at 20 derivations, topographically localized according to the 10-20 International System. A computerized routine for automatic N400-peak marking (based on the ascendant zero-cross of the first waveform derivative) was applied to the estimated individual ERP waveform for congruous and incongruous sentences in both series for all ERP topographic derivations. Peak-to-peak N400 amplitude was significantly augmented (P < 0.05; one-sided Wilcoxon signed-rank test) due to incongruence in derivations F3, T3, C3, Cz, T5, P3, Pz, and P4 for nominal object series and in P3, Pz and P4 for pronominal object series. The results also indicated high inter-individual variability in ERP waveforms, suggesting that the usual procedure of grand averaging might not be considered a generally adequate approach. Hence, signal processing statistical techniques should be applied in neurolinguistic ERP studies allowing waveform analysis with low signal-to-noise ratio.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to determine the adequate cortical regions based on the signal-to-noise ratio (SNR) for somatosensory evoked potential (SEP) recording. This investigation was carried out using magnitude-squared coherence (MSC), a frequency domain objective response detection technique. Electroencephalographic signals were collected (International 10-20 System) from 38 volunteers, without history of neurological pathology, during somatosensory stimulation. Stimuli were applied to the right posterior tibial nerve at the rate of 5 Hz and intensity slightly above the motor threshold. Response detection was based on rejecting the null hypothesis of response absence (significance level α= 0.05 and M = 500 epochs). The best detection rates (maximum percentage of volunteers for whom the response was detected for the frequencies between 4.8 and 72 Hz) were obtained for the parietal and central leads mid-sagittal and ipsilateral to the stimulated leg: C4 (87%), P4 (82%), Cz (89%), and Pz (89%). The P37-N45 time-components of the SEP can also be observed in these leads. The other leads, including the central and parietal contralateral and the frontal and fronto-polar leads, presented low detection capacity. If only contralateral leads were considered, the centro-parietal region (C3 and P3) was among the best regions for response detection, presenting a correspondent well-defined N37; however, this was not observed in some volunteers. The results of the present study showed that the central and parietal regions, especially sagittal and ipsilateral to the stimuli, presented the best SNR in the gamma range. Furthermore, these findings suggest that the MSC can be a useful tool for monitoring purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Différentes méthodes ayant pour objectif une utilisation optimale d'antennes radio-fréquences spécialisées en imagerie par résonance magnétique sont développées et validées. Dans un premier temps, il est démontré qu'une méthode alternative de combinaison des signaux provenant des différents canaux de réception d'un réseau d'antennes mène à une réduction significative du biais causé par la présence de bruit dans des images de diffusion, en comparaison avec la méthode de la somme-des-carrés généralement utilisée. Cette réduction du biais engendré par le bruit permet une amélioration de l'exactitude de l'estimation de différents paramètres de diffusion et de diffusion tensorielle. De plus, il est démontré que cette méthode peut être utilisée conjointement avec une acquisition régulière sans accélération, mais également en présence d'imagerie parallèle. Dans une seconde perspective, les bénéfices engendrés par l'utilisation d'une antenne d'imagerie intravasculaire sont étudiés. Suite à une étude sur fantôme, il est démontré que l'imagerie par résonance magnétique intravasculaire offre le potentiel d'améliorer significativement l'exactitude géométrique lors de mesures morphologiques vasculaires, en comparaison avec les résultats obtenus avec des antennes de surface classiques. Il est illustré qu'une exactitude géométrique comparable à celle obtenue grâce à une sonde ultrasonique intravasculaire peut être atteinte. De plus, plusieurs protocoles basés sur une acquisition de type balanced steady-state free-precession sont comparés dans le but de mettre en évidence différentes relations entre les paramètres utilisés et l'exactitude géométrique obtenue. En particulier, des dépendances entre la taille du vaisseau, le rapport signal-sur-bruit à la paroi vasculaire, la résolution spatiale et l'exactitude géométrique atteinte sont mises en évidence. Dans une même optique, il est illustré que l'utilisation d'une antenne intravasculaire permet une amélioration notable de la visualisation de la lumière d'une endoprothèse vasculaire. Lorsque utilisée conjointement avec une séquence de type balanced steady-state free-precession utilisant un angle de basculement spécialement sélectionné, l'imagerie par résonance magnétique intravasculaire permet d'éliminer complètement les limitations normalement engendrées par l'effet de blindage radio-fréquence de l'endoprothèse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cette thèse porte sur l’amélioration des techniques d’imagerie à haut-contraste permettant la détection directe de compagnons à de faibles séparations de leur étoile hôte. Plus précisément, elle s’inscrit dans le développement du Gemini Planet Imager (GPI) qui est un instrument de deuxième génération pour les télescopes Gemini. Cette caméra utilisera un spectromètre à champ intégral (SCI) pour caractériser les compagnons détectés et pour réduire le bruit de tavelure limitant leur détection et corrigera la turbulence atmosphérique à un niveau encore jamais atteint en utilisant deux miroirs déformables dans son système d’optique adaptative (OA) : le woofer et le tweeter. Le woofer corrigera les aberrations de basses fréquences spatiales et de grandes amplitudes alors que le tweeter compensera les aberrations de plus hautes fréquences ayant une plus faible amplitude. Dans un premier temps, les performances pouvant être atteintes à l’aide des SCIs présentement en fonction sur les télescopes de 8-10 m sont investiguées en observant le compagnon de l’étoile GQ Lup à l’aide du SCI NIFS et du système OA ALTAIR installés sur le télescope Gemini Nord. La technique de l’imagerie différentielle angulaire (IDA) est utilisée pour atténuer le bruit de tavelure d’un facteur 2 à 6. Les spectres obtenus en bandes JHK ont été utilisés pour contraindre la masse du compagnon par comparaison avec les prédictions des modèles atmosphériques et évolutifs à 8−60 MJup, où MJup représente la masse de Jupiter. Ainsi, il est déterminé qu’il s’agit plus probablement d’une naine brune que d’une planète. Comme les SCIs présentement en fonction sont des caméras polyvalentes pouvant être utilisées pour plusieurs domaines de l’astrophysique, leur conception n’a pas été optimisée pour l’imagerie à haut-contraste. Ainsi, la deuxième étape de cette thèse a consisté à concevoir et tester en laboratoire un prototype de SCI optimisé pour cette tâche. Quatre algorithmes de suppression du bruit de tavelure ont été testés sur les données obtenues : la simple différence, la double différence, la déconvolution spectrale ainsi qu’un nouvel algorithme développé au sein de cette thèse baptisé l’algorithme des spectres jumeaux. Nous trouvons que l’algorithme des spectres jumeaux est le plus performant pour les deux types de compagnons testés : les compagnons méthaniques et non-méthaniques. Le rapport signal-sur-bruit de la détection a été amélioré d’un facteur allant jusqu’à 14 pour un compagnon méthanique et d’un facteur 2 pour un compagnon non-méthanique. Dernièrement, nous nous intéressons à certains problèmes liés à la séparation de la commande entre deux miroirs déformables dans le système OA de GPI. Nous présentons tout d’abord une méthode utilisant des calculs analytiques et des simulations Monte Carlo pour déterminer les paramètres clés du woofer tels que son diamètre, son nombre d’éléments actifs et leur course qui ont ensuite eu des répercussions sur le design général de l’instrument. Ensuite, le système étudié utilisant un reconstructeur de Fourier, nous proposons de séparer la commande entre les deux miroirs dans l’espace de Fourier et de limiter les modes transférés au woofer à ceux qu’il peut précisément reproduire. Dans le contexte de GPI, ceci permet de remplacer deux matrices de 1600×69 éléments nécessaires pour une séparation “classique” de la commande par une seule de 45×69 composantes et ainsi d’utiliser un processeur prêt à être utilisé plutôt qu’une architecture informatique plus complexe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il est bien connu que les enfants qui présentent un trouble de traitement auditif (TTA) ont de la difficulté à percevoir la parole en présence de bruit de fond. Cependant, il n’existe aucun consensus quant à l’origine de ces difficultés d’écoute. Ce programme de recherche est consacré à l’étude des incapacités sous-jacentes aux problèmes de perception de la parole dans le bruit chez les enfants présentant un TTA. Le Test de Phrases dans le Bruit (TPB) a été développé afin d’examiner si les difficultés de perception de la parole dans le bruit d’enfants ayant un TTA relèvent d’incapacités auditives, d’incapacités cognitivo-linguistiques ou des deux à la fois. Il comprend cinq listes de 40 phrases, composées de 20 phrases hautement prévisibles (HP) et de 20 phrases faiblement prévisibles (FP), de même qu’un bruit de verbiage. Le niveau de connaissance du mot clé (mot final) de chaque phrase a été vérifié auprès d’un groupe d’enfants âgés entre 5 et 7 ans. De plus, le degré d’intelligibilité des phrases dans le bruit et le niveau de prévisibilité ont été mesurées auprès d’adultes pour assurer l’équivalence entre les listes. Enfin, le TPB a été testé auprès d’un groupe de 15 adultes et d’un groupe de 69 enfants sans trouble auditif avant de l’administrer à des enfants ayant un TTA. Pour répondre à l’objectif général du programme de recherche, dix enfants présentant un TTA (groupe TTA) et dix enfants jumelés selon le genre et l’âge sans difficulté auditive (groupe témoin) ont été soumis aux listes de phrases du TPB selon différentes conditions sonores. Le groupe TTA a obtenu des performances significativement plus faibles comparativement au groupe témoin à la tâche de reconnaissance du mot final des phrases présentées en même temps qu’un bruit de verbiage compétitif, aux rapports signal-sur-bruit de 0, +3 et +4 dB. La moyenne de la différence des scores obtenue entre les phrases HP et FP à chaque condition expérimentale de bruit était similaire entre les deux groupes. Ces résultats suggèrent que les enfants ayant un TTA ne se distinguent pas des enfants du groupe témoin au plan de la compétence cognitivo-linguistique. L’origine des difficultés d’écoute de la parole dans le bruit dans le cas de TTA serait de nature auditive. Toutefois, les résultats des analyses de groupe diffèrent de ceux des analyses individuelles. Les divers profils de difficultés d’écoute identifiés auprès de cette cohorte appuient l’importance de continuer les investigations afin de mieux comprendre l’origine des problèmes de perception de la parole dans le bruit dans le cas de TTA. En connaissant mieux la nature de ces difficultés, il sera possible d’identifier les stratégies d’intervention de réadaptation spécifiques et efficaces.