812 resultados para Stereotaxic Techniques.
Resumo:
Chest physiotherapy (CP) using passive expiratory manoeuvres is widely used in Western Europe for the treatment of bronchiolitis, despite lacking evidence for its efficacy. We undertook an open randomised trial to evaluate the effectiveness of CP in infants hospitalised for bronchiolitis by comparing the time to clinical stability, the daily improvement of a severity score and the occurrence of complications between patients with and without CP. Children <1 year admitted for bronchiolitis in a tertiary hospital during two consecutive respiratory syncytial virus seasons were randomised to group 1 with CP (prolonged slow expiratory technique, slow accelerated expiratory flow, rarely induced cough) or group 2 without CP. All children received standard care (rhinopharyngeal suctioning, minimal handling, oxygen for saturation ≥92%, fractionated meals). Ninety-nine eligible children (mean age, 3.9 months), 50 in group 1 and 49 in group 2, with similar baseline variables and clinical severity at admission. Time to clinical stability, assessed as primary outcome, was similar for both groups (2.9 ± 2.1 vs. 3.2 ± 2.8 days, P = 0.45). The rate of improvement of a clinical and respiratory score, defined as secondary outcome, only showed a slightly faster improvement of the respiratory score in the intervention group when including stethoacoustic properties (P = 0.044). Complications were rare but occurred more frequently, although not significantly (P = 0.21), in the control arm. In conclusion, this study shows the absence of effectiveness of CP using passive expiratory techniques in infants hospitalised for bronchiolitis. It seems justified to recommend against the routine use of CP in these patients.
Resumo:
Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.
Resumo:
This paper presents a pattern recognition method focused on paintings images. The purpose is construct a system able to recognize authors or art styles based on common elements of his work (here called patterns). The method is based on comparing images that contain the same or similar patterns. It uses different computer vision techniques, like SIFT and SURF, to describe the patterns in descriptors, K-Means to classify and simplify these descriptors, and RANSAC to determine and detect good results. The method are good to find patterns of known images but not so good if they are not.
Resumo:
In European countries and North America, people spend 80 to 90% of time inside buildings and thus breathe indoor air. In Switzerland, special attention has been devoted to the 16 stations of the national network of observation of atmospheric pollutants (NABEL). The results indicate a reduction in outdoor pollution over the last ten years. With such a decrease in pollution over these ten years the question becomes: how can we explain an increase of diseases? Indoor pollution can be the cause. Indoor contaminants that may create indoor air quality (IAQ) problems come from a variety of sources. These can include inadequate ventilation, temperature and humidity dysfunction, and volatile organic compounds (VOCs). The health effects from these contaminants are varied and can range from discomfort, irritation and respiratory diseases to cancer. Among such contaminants, environmental tobacco smoke (ETS) could be considered the most important in terms of both health effects and engineering controls of ventilation. To perform indoor pollution monitoring, several selected ETS tracers can be used including carbon monoxide (CO), carbon dioxide (CO2), respirable particles (RSP), condensate, nicotine, polycyclic aromatic hydrocarbons (PAHs), nitrosamines, etc. In this paper, some examples are presented of IAQ problems that have occurred following the renewal of buildings and energy saving concerns. Using industrial hygiene sampling techniques and focussing on selected priority pollutants used as tracers, various problems have been identified and solutions proposed. [Author]
Resumo:
Often practical performance of analytical redundancy for fault detection and diagnosis is decreased by uncertainties prevailing not only in the system model, but also in the measurements. In this paper, the problem of fault detection is stated as a constraint satisfaction problem over continuous domains with a big number of variables and constraints. This problem can be solved using modal interval analysis and consistency techniques. Consistency techniques are then shown to be particularly efficient to check the consistency of the analytical redundancy relations (ARRs), dealing with uncertain measurements and parameters. Through the work presented in this paper, it can be observed that consistency techniques can be used to increase the performance of a robust fault detection tool, which is based on interval arithmetic. The proposed method is illustrated using a nonlinear dynamic model of a hydraulic system
Resumo:
The speed of fault isolation is crucial for the design and reconfiguration of fault tolerant control (FTC). In this paper the fault isolation problem is stated as a constraint satisfaction problem (CSP) and solved using constraint propagation techniques. The proposed method is based on constraint satisfaction techniques and uncertainty space refining of interval parameters. In comparison with other approaches based on adaptive observers, the major advantage of the presented method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements and model errors and without the monotonicity assumption. In order to illustrate the proposed approach, a case study of a nonlinear dynamic system is presented
Resumo:
Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.
Resumo:
Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.
Resumo:
La faiblesse des muscles respiratoires peut entraîner une dyspnée, un encombrement bronchique et une insuffisance respiratoire potentiellement fatale. L'évaluation de la force musculaire respiratoire s'impose donc dans les affections neuro-musculaires, mais également dans les situations de dyspnée inexpliquée par une première évaluation cardiaque et pulmonaire. À la spirométrie, une faiblesse musculaire est suspectée sur la base de la boucle débit-volume montrant un débit de pointe émoussé et une fin prématurée de l'expiration. Une diminution importante de la capacité vitale en position couchée suggère une paralysie diaphragmatique. La force inspiratoire est mesurée par la pression inspiratoire maximale (PImax) contre une quasi-occlusion des voies aériennes. Ce test relativement difficile est d'interprétation délicate en cas de collaboration insuffisante. La mesure de la pression nasale sniff (SNIP) est une alternative utile, car elle élimine le problème des fuites autour de l'embout buccal et la réalisation du reniflement est facile. De même, la pression trans-diaphragmatique sniff mesure la force du diaphragme au moyen de sondes oesophagienne et gastrique. En cas de collaboration insuffisante, on peut recourir à la stimulation magnétique des nerfs phréniques qui induit une contraction non-volontaire du diaphragme. La force expiratoire est mesurée par la pression expiratoire maximale (PEmax) contre une quasi-occlusion. La force disponible pour tousser est mesurée par la pression gastrique à la toux, ou plus simplement par le débit de pointe à la toux. Chez les patients à risque, la mesure de la force des muscles respiratoires permet d'instaurer à temps une assistance ventilatoire ou à la toux.
Analysis and evaluation of techniques for the extraction of classes in the ontology learning process
Resumo:
This paper analyzes and evaluates, in the context of Ontology learning, some techniques to identify and extract candidate terms to classes of a taxonomy. Besides, this work points out some inconsistencies that may be occurring in the preprocessing of text corpus, and proposes techniques to obtain good terms candidate to classes of a taxonomy.
Investigation into Improved Pavement Curing Materials and Techniques: Part 2 - Phase III, March 2003
Resumo:
Appropriate curing is important for concrete to obtain the designed properties. This research was conducted to evaluate the curing effects of different curing materials and methods on pavement properties. At present the sprayed curing compound is a common used method for pavement and other concrete structure construction. Three curing compounds were selected for testing. Two different application rates were employed for the white-pigmented liquid curing compounds. The concrete properties of temperature, moisture content, conductivity, and permeability were examined at several test locations. It was found, in this project, that the concrete properties varied with the depth. Of the tests conducted (maturity, sorptivity, permeability, and conductivity), conductivity appears to be the best method to evaluate the curing effects in the field and bears potential for field application. The results indicated that currently approved curing materials in Iowa, when spread uniformly in a single or double application, provide adequate curing protection and meet the goals of the Iowa Department of Transportation. Experimental curing methods can be compared to this method through the use of conductivity testing to determine their application in the field.
Resumo:
Concrete curing is closely related to cement hydration, microstructure development, and concrete performance. Application of a liquid membrane-forming curing compound is among the most widely used curing methods for concrete pavements and bridge decks. Curing compounds are economical, easy to apply, and maintenance free. However, limited research has been done to investigate the effectiveness of different curing compounds and their application technologies. No reliable standard testing method is available to evaluate the effectiveness of curing, especially of the field concrete curing. The present research investigates the effects of curing compound materials and application technologies on concrete properties, especially on the properties of surface concrete. This report presents a literature review of curing technology, with an emphasis on curing compounds, and the experimental results from the first part of this research—lab investigation. In the lab investigation, three curing compounds were selected and applied to mortar specimens at three different times after casting. Two application methods, single- and double-layer applications, were employed. Moisture content, conductivity, sorptivity, and degree of hydration were measured at different depths of the specimens. Flexural and compressive strength of the specimens were also tested. Statistical analysis was conducted to examine the relationships between these material properties. The research results indicate that application of a curing compound significantly increased moisture content and degree of cement hydration and reduced sorptivity of the near-surface-area concrete. For given concrete materials and mix proportions, optimal application time of curing compounds depended primarily upon the weather condition. If a sufficient amount of a high-efficiency-index curing compound was uniformly applied, no double-layer application was necessary. Among all test methods applied, the sorptivity test is the most sensitive one to provide good indication for the subtle changes in microstructure of the near-surface-area concrete caused by different curing materials and application methods. Sorptivity measurement has a close relation with moisture content and degree of hydration. The research results have established a baseline for and provided insight into the further development of testing procedures for evaluation of curing compounds in field. Recommendations are provided for further field study.
Resumo:
Standards for the construction of full-depth patching in portland cement concrete pavement usually require replacement of all deteriorated based materials with crushed stone, up to the bottom of the existing pavement layer. In an effort to reduce the time of patch construction and costs, the Iowa Department of Transportation and the Department of Civil, Construction and Environmental Engineering at Iowa State University studied the use of extra concrete depth as an option for base construction. This report compares the impact of additional concrete patching material depth on rate of strength gain, potential for early opening to traffic, patching costs, and long-term patch performance. This report also compares those characteristics in terms of early setting and standard concrete mixes. The results have the potential to change the method of Portland cement concrete pavement patch construction in Iowa.