946 resultados para Steam injection.
Resumo:
This paper presents a study of the three-dimensional flow field within the blade rows of a high-pressure axial flow steam turbine stage. Compound lean angles have been employed to achieve relatively low blade loading for hub and tip section and so reduce the secondary losses. The flow field is investigated in a Low-Speed Research Turbine using pneumatic and hot-wire probes downstream of the blade row. Steady and unsteady numerical simulations were performed using structured 3D Navier-Stokes solver to further understand the flow field. Agreement between the simulations and the measurements has been found. The unsteady measurements indicate that there is a significant effect of the stator flow interaction in the downstream rotor blade. The transport of the stator viscous flow through the rotor blade row is described. Unsteady numerical simulations were found to be successful in predicting accurately the flow near the secondary flow interaction regions compared to steady simulations. A method to calculate the unsteady loss generated inside the blade row was developed from the steady numerical simulations. The contribution of various regions in the blade to the unsteady loss generation was evaluated. This method can assist the designer in identifying and optimizing the features of the flow that are responsible for the majority of the unsteady loss production. An analytical model was developed to quantify this effect for the vortex transport inside the downstream blade.
Resumo:
Numerical techniques for non-equilibrium condensing flows are presented. Conservation equations for homogeneous gas-liquid two-phase compressible flows are solved by using a finite volume method based on an approximate Riemann solver. The phase change consists of the homogeneous nucleation and growth of existing droplets. Nucleation is computed with the classical Volmer-Frenkel model, corrected for the influence of the droplet temperature being higher than the steam temperature due to latent heat release. For droplet growth, two types of heat transfer model between droplets and the surrounding steam are used: a free molecular flow model and a semi-empirical two-layer model which is deemed to be valid over a wide range of Knudsen number. The computed pressure distribution and Sauter mean droplet diameters in a convergent-divergent (Laval) nozzle are compared with experimental data. Both droplet growth models capture qualitatively the pressure increases due to sudden heat release by the non-equilibrium condensation. However the agreement between computed and experimental pressure distributions is better for the two-layer model. The droplet diameter calculated by this model also agrees well with the experimental value, whereas that predicted by the free molecular model is too small. Condensing flows in a steam turbine cascade are calculated at different Mach numbers and inlet superheat conditions and are compared with experiments. Static pressure traverses downstream from the blade and pressure distributions on the blade surface agree well with experimental results in all cases. Once again, droplet diameters computed with the two-layer model give best agreement with the experiments. Droplet sizes are found to vary across the blade pitch due to the significant variation in expansion rate. Flow patterns including oblique shock waves and condensation-induced pressure increases are also presented and are similar to those shown in the experimental Schlieren photographs. Finally, calculations are presented for periodically unsteady condensing flows in a low expansion rate, convergent-divergent (Laval) nozzle. Depending on the inlet stagnation subcooling, two types of self-excited oscillations appear: a symmetric mode at lower inlet subcooling and an asymmetric mode at higher subcooling. Plots of oscillation frequency versus inlet sub-cooling exhibit a hysteresis loop, in accord with observations made by other researchers for moist air flow. Copyright © 2006 by ASME.
Resumo:
A compact trench-gate IGBT model that captures MOS-side carrier injection is developed. The model retains the simplicity of a one-dimensional solution to the ambipolar diffusion equation, but at the same time captures MOS-side carrier injection and its effects on steady-state carrier distribution in the drift region and on switching waveforms. © 2007 IEEE.
Resumo:
This paper describes an experimental investigation into the effect of unsteady fuel injection on the performance of a valveless pulse combustor. Two fuel systems were used. The first delivered a steady flow of ethylene through choked nozzles, and the second delivered ethylene in discrete pulses using high-frequency fuel injectors. Both fuel systems injected directly into the combustion chamber. The high-frequency fuel injectors were phase locked to the unsteady pressure measured on the inlet pipe. The phase and opening pulse width of the injectors and the time-averaged fuel mass flow rate through the injectors were independently varied. For a given fuel mass flow rate, it is shown that the maximum pressure amplitude occurs when fuel is injected during flow reversal in the inlet pipe, i.e. flow direction is out of the combustor. The optimal fuel injection pulse width is shown to be approximately 2/9th of the cycle. It should, however, be noted that this is the shortest time in which the injectors can reliably be fully opened and closed. It is shown that by using unsteady fuel injection the mass flow rate of fuel needed to achieve a given amplitude of unsteady pressure can be reduced by up to 65% when compared with the steady fuel injection case. At low fuel mass flow rates unsteady fuel injection is shown to raise the efficiency of the combustor by a factor of 7 decreasing to a factor of 2 at high fuel mass flow rates. Copyright © 2008 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
Research has begun on Microbial Carbonate Precipitation (MCP), which shows promise as a soil improvement method because of its low carbon dioxide emission compared to cement stabilized agents. MCP produces calcium carbonate from carbonates and calcium in soil voids through ureolysis by "Bacillus Pasteurii". This study focuses on how the amount of calcium carbonate precipitation is affected by the injection conditions of the microorganism and nutrient salt, such as the number of injections and the soil type. Experiments were conducted to simulate soil improvement by bio-grouting soil in a syringe. The results indicate that the amount of precipitation is affected by injection conditions and soil type, suggesting that, in order for soil improvement by MCP to be effective, it is necessary to set injection conditions that are in accordance with the soil conditions. © 2011 ASCE.