999 resultados para Specific ultraviolet absorbance (SUVA)
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.
Resumo:
A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.
Resumo:
This article describes the standardization and evaluation of an in-house specific IgG avidity ELISA for distinguishing recent primary from long-term human cytomegalovirus (HCMV) infection. The test was standardized with the commercial kit ETI-CYTOK G Plus (Sorin Biomedica, Italy) using 8 M urea in phosphate-buffered saline to dissociate low-avidity antibodies after the antigen-antibody interaction. The performance of the in-house assay was compared to that of the commercial automated VIDAS CMV IgG avidity test (bioMérieux, France). Forty-nine sera, 24 from patients with a recent primary HCMV infection and 25 from patients with a long-term HCMV infection and a sustained persistence of specific IgM antibodies, were tested. Similar results were obtained with the two avidity methods. All 24 sera from patients with recently acquired infection had avidity indices compatible with acute HCMV infection by the VIDAS method, whereas with the in-house method, one serum sample had an equivocal result. In the 25 sera from patients with long-term infection, identical results were obtained with the two methods, with only one serum sample having an incompatible value. These findings suggest that our in-house avidity test could be a potentially useful tool for the immunodiagnosis of HCMV infection.
Resumo:
Dissertation presented to obtain the Ph.D degree in Molecular Biology
Resumo:
In order to evaluate the potential allergenicity of Blomia tropicalis (Bt) antigen, IgE production of both specific and non-specific for Bt antigen was monitored in BALB/c mice after exposure to the antigen by nasal route. It was evidenced that B. tropicalis contains a functional allergen in its components. The allergenic components, however, when administered intranasally without any adjuvant, did not function to induce IgE response within a short period. On the other hand, intranasal inoculation of Bt antigens augmented serum IgE responses in mice pretreated by a subcutaneous priming injection of the same antigens. Inoculation of Bt antigen without subcutaneous priming injections induced IgE antibody production only when the antigen was continuously administered for a long period of over 24 weeks. Even when the priming injection was absent, the Bt antigen inoculated with cholera toxin (CT) as a mucosal adjuvant also significantly augmented the Bt antigen-specific IgE responses depending on the dose of CT co-administered. The present study also demonstrated that Bt antigen/CT-inoculated mice showed increased non-specific serum IgE level and peripheral blood eosinophil rates without noticeable elevations of the total leukocyte counts. The immunoblot analysis demonstrated 5 main antigenic components reactive to IgE antibodies induced. These components at about 44-64 kDa position were considered to be an important candidate antigen for diagnosis of the mite-related allergy.
Resumo:
Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.
Resumo:
The interaction between specific immune response to Schistosoma mansoni and praziquantel (PZQ) was studied in mice. In mice harboring concomitant immunity, 6-day-old parasites treated with PZQ were more effectively removed than 24h treated parasites despite both had a significant worm burden reduction when compared with respective treated controls. These results show that PZQ can be effective at the skin and lung stages of parasite's development mainly acting with a established specific immune response, and particularly at the lung phase.
Resumo:
In the present work, the development of a genosensor for the event-specific detection of MON810 transgenic maize is proposed. Taking advantage of nanostructuration, a cost-effective three dimensional electrode was fabricated and a ternary monolayer containing a dithiol, a monothiol and the thiolated capture probe was optimized to minimize the unspecific signals. A sandwich format assay was selected as a way of precluding inefficient hybridization associated with stable secondary target structures. A comparison between the analytical performance of the Au nanostructured electrodes and commercially available screen-printed electrodes highlighted the superior performance of the nanostructured ones. Finally, the genosensor was effectively applied to detect the transgenic sequence in real samples, showing its potential for future quantitative analysis.
Resumo:
Toxoplasmosis is an usually asymptomatic worldwide disseminated infection. In its congenital presentation it may lead to abortion or fetal malformations. Antenatal evaluation is considered of paramount importance to identify seronegative women and allow for prophylaxis. Recent improvements in sensitivity of IgM tests has made IgM detection an extremely protracted acute phase marker, and IgG avidity evaluation test became necessary. Observation has shown that a correlation can be established between IgM levels and avidity percentages, suggesting that frequently the avidity test may not be necessary. In this study we analyzed Toxoplasma gondii IgM levels of 202 samples and their IgG avidity percentages, in order to define specific levels whose IgM quantification could by itself define serodiagnosis and therefore make the avidity evaluation unnecessary. We showed that for IgM levels bellow 2.0 and above 6.0 serodiagnosis of toxoplasmosis could be established without need of IgG avidity test. IgM levels between these two parameters are associated with varying avidity indexes highlighting the importance of its evaluation as a means to confirm toxoplasmosis. Following this demonstration it was possible to avoid the avidity test for 75% of the cases, to reduce the turnaround time and to reduce costs.
Resumo:
In South Brazil the circulation of two HIV-1 subtypes with different characteristics represents an important scenario for the study of the impact of HIV-1 diversity on the evolution of the HIV-1 epidemic and AIDS disease. HIV-1 B, the predominant variant in industrialized countries and HIV-1 C, the most prevalent subtype in areas with rapid epidemic growth, are implicated in most infections. We evaluated blood samples from 128 antiretroviral (ARV) naïve patients recruited at entry to the largest HIV outpatient service in Porto Alegre. Based on partial pol region sequencing, HIV-1 C was observed in 29%, HIV-1 B in 22.6% and, the recently identified CRF31_BC, in 23.4% of 128 volunteers. Other variants were HIV-1 F in 10% and other mosaics in 5.5%. In order to evaluate the association of socio-behavioral characteristics and HIV-1 subtypes, interviews and laboratory evaluation were performed at entry. Our data suggest an established epidemic of the three major variants, without any evidence of partitioning in either of the subgroups analyzed. However, anal sex practices were associated with subtype B, which could indicate a greater transmissibility of non-B variants by vaginal intercourse. This study provides baseline information for epidemiologic surveillance of the changes of the molecular characteristics of HIV-1 epidemics in this region.
Resumo:
The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.
Resumo:
This dissertation is presented to obtain a Master degree in Structural and Functional Biochemistry