911 resultados para Secondary ion mass spectrometry
Resumo:
In pre-implantation embryos, lipids play key roles in determining viability, cryopreservation and implantation properties, but often their analysis is analytically challenging because of the few picograms of analytes present in each of them. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) allows obtaining individual phospholipid profiles of these microscopic organisms. This technique is sensitive enough to enable analysis of individual intact embryos and monitoring the changes in membrane lipid composition in the early stages of development serving as screening method for studies of biology and biotechnologies of reproduction. This article introduces an improved, more comprehensive MALDI-MS lipid fingerprinting approach that considerably increases the lipid information obtained from a single embryo. Using bovine embryos as a biological model, we have also tested optimal sample storage and handling conditions before the MALDI-MS analysis. Improved information at the molecular level is provided by the use of a binary matrix that enables phosphatidylcholines, sphingomyelins, phosphatidylserines, phosphatidylinositols and phosphoethanolamines to be detected via MALDI(±)-MS in both the positive and negative ion modes. An optimal MALDI-MS protocol for lipidomic monitoring of a single intact embryo is therefore reported with potential applications in human and animal reproduction, cell development and stem cell research. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
The complexity of biological samples poses a major challenge for reliable compound identification in mass spectrometry (MS). The presence of interfering compounds that cause additional peaks in the spectrum can make interpretation and assignment difficult. To overcome this issue, new approaches are needed to reduce complexity and simplify spectral interpretation. Recently, focused on unknown metabolite identification, we presented a new approach, RANSY (ratio analysis of nuclear magnetic resonance spectroscopy; Anal. Chem. 2011, 83, 7616-7623), which extracts the signals related to the same metabolite based on peak intensity ratios. On the basis of this concept, we present the ratio analysis of mass spectrometry (RAMSY) method, which facilitates improved compound identification in complex MS spectra. RAMSY works on the principle that, under a given set of experimental conditions, the abundance/intensity ratios between the mass fragments from the same metabolite are relatively constant. Therefore, the quotients of average peak ratios and their standard deviations, generated using a small set of MS spectra from the same ion chromatogram, efficiently allow the statistical recovery of the metabolite peaks and facilitate reliable identification. RAMSY was applied to both gas chromatography/MS and liquid chromatography tandem MS (LC-MS/MS) data to demonstrate its utility. The performance of RAMSY is typically better than the results from correlation methods. RAMSY promises to improve unknown metabolite identification for MS users in metabolomics or other fields.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Comprehensive two-dimensional gas chromatography (GC x GC) is a powerful technique that provides excellent separation and identification of analytes in highly complex samples with considerable increase in GC peak capacities. However, since second dimension analyses are very fast, detectors with a rapid acquisition rate are required. Over the last years, quite a number of studies have discussed the potential and limitations of the combination GC x GC with a variety of quadrupole mass spectrometers. The present research focuses on the evaluation of qMS effectiveness at a 10,000-amu/s scan speed and 20-Hz scan frequency for the identification (full scan mode acquisition-TIC) and quantification (extracted ion chromatogram) of target pesticide residues in tomato samples. The following MS parameters have been evaluated: number of data points per peak, mass spectrum quality, peak skewing, and sensitivity. The validated proposed GC x GC/qMS method presented satisfactory results in terms of repeatability (coefficient of variation lower than 15%), accuracy (84-117%), and linearity (ranging from 25 to 500 ng/g), while significant enhancement in sensitivity was observed (a factor of around 10) under scan conditions. (C) 2012 Elsevier B.V. All rights reserved.
Development of Nanoinjector Devices for Electrospray Ionization - Tandem Mass Spectrometry (ESI-MSn)
Resumo:
In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 mu L of sample.
Resumo:
A fast and sensitive method for the simultaneous determination of Sudan dyes (I, II, III, and IV) in food samples was developed for the first time using partial filling micellar electrokinectic chromatography-mass spectrometry (MEKC-MS). The use of MEKC was essential to achieve the separation of these neutral analytes, while the partial filling technique was necessary to avoid the contamination of the ion source with non-volatile micelles. MEKC separation and MS detection conditions were optimized in order to achieve a fast, efficient, and sensitive separation of the four dyes. Filling 25% of the capillary with an MEKC solution containing 40 mM ammonium bicarbonate, 25 mM SDS, and 32.5% (v/v) acetonitrile, a baseline separation of the four azo-dyes was obtained in 10 min. Tandem MS was investigated in order to improve the sensitivity and selectivity of the analysis. Limits of detection (LOD) values 5, 8, 15, and 29 times better were obtained for Sudan III, I, II, and IV, respectively, using partial filling MEKC-MS/MS instead of partial filling MEKC-MS. Under optimized conditions, LOD from 0.05 to 0.2 mu g/mL were obtained. The suitability of the developed method was demonstrated through the fast and sensitive determination of Sudan I, II, III, and IV in spiked chilli powder samples. This determination could not be achieved by MEKC-UV due to the existence of several interfering compounds from the matrix.
Resumo:
Carvedilol is an antihypertensive drug available as a racemic mixture. (-)-(S)-carvedilol is responsible for the nonselective beta-blocker activity but both enantiomers present similar activity on a1-adrenergic receptor. To our knowledge, this is the first study of carvedilol enantiomers in human plasma using a chiral stationary phase column and liquid chromatography with tandem mass spectrometry. The method involves plasma extraction with diisopropyl ether using metoprolol as internal standard and direct separation of the carvedilol enantiomers on a Chirobiotic T (R) (Teicoplanin) column. Protonated ions [M + H]+ and their respective ion products were monitored at transitions of 407 > 100 for the carvedilol enantiomers and 268 > 116 for the internal standard. The quantification limit was 0.2 ng ml-1 for both enantiomers in plasma. The method was applied to study enantioselectivity in the pharmacokinetics of carvedilol administered as a single dose of 25 mg to a hypertensive patient. The results showed a higher plasma concentration of (+)-(R)-carvedilol (AUC08 205.52 vs. 82.61 (ng h) ml-1), with an enantiomer ratio of 2.48. Chirality, 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Analytic methods were applied and validated to measure residues of chlorfenvinphos, fipronil, and cypermethrin in meat and bovine fat, using the QuEChERS method and gas chromatography-mass spectrometry. For the meat, 2 g of sample, 4mL of acetonitrile, 1.6 g of MgSO4, and 0.4 g of NaCl were used in the liquid-liquid partition, while 80 mg of C18, 80 mg of primary and secondary amine and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction. For the fat, 1 g of sample, 5 mL of hexane, 10 mL of water, 10 mL of acetonitrile, 4 g of MgSO4, and 0.5 g of NaCl were used in the liquid-liquid partition and 50 mg of primary and secondary amine and 150 mg of MgSO4 were used in the dispersive solid-phase extraction. The recovery percentages obtained for the pesticides in meat at different concentrations ranged from 81 to 129% with relative standard deviation below 27%. The corresponding results from the fat ranged from 70 to 123% with relative standard deviation below 25%. The methods showed sensitivity, precision, and accuracy according to EPA standards and quantification limits below the maximum residue limit established by European Union, except for chlorfenvinphos in the fat.
Resumo:
In order to understand the influence of alkyl side chains on the gas-phase reactivity of 1,4-naphthoquinone derivatives, some 2-hydroxy-1,4-naphthoquinone derivatives have been prepared and studied by electrospray ionization tandem mass spectrometry in combination with computational quantum chemistry calculations. Protonation and deprotonation sites were suggested on the basis of gas-phase basicity, proton affinity, gas-phase acidity (?Gacid), atomic charges and frontier orbital analyses. The nature of the intramolecular interaction as well as of the hydrogen bond in the systems was investigated by the atoms-in-molecules theory and the natural bond orbital analysis. The results were compared with data published for lapachol (2-hydroxy-3-(3-methyl-2-butenyl)-1,4-naphthoquinone). For the protonated molecules, water elimination was verified to occur at lower proportion when compared with side chain elimination, as evidenced in earlier studies on lapachol. The side chain at position C(3) was found to play important roles in the fragmentation mechanisms of these compounds. Copyright (c) 2012 John Wiley & Sons, Ltd.
Development of nanoinjector devices for electrospray ionization - tandem mass spectrometry (ESI-MSn)
Resumo:
In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 µL of sample.
Resumo:
Heutzutage gewähren hochpräzise Massenmessungen mit Penning-Fallen tiefe Einblicke in die fundamentalen Eigenschaften der Kernmaterie. Zu diesem Zweck wird die freie Zyklotronfrequenz eines Ions bestimmt, das in einem starken, homogenen Magnetfeld gespeichert ist. Am ISOLTRAP-Massenspektrometer an ISOLDE / CERN können die Massen von kurzlebigen, radioaktiven Nukliden mit Halbwertszeiten bis zu einigen zehn ms mit einer Unsicherheit in der Größenordnung von 10^-8 bestimmt werden. ISOLTRAP besteht aus einem Radiofrequenz-Quadrupol zum akkumulieren der von ISOLDE gelieferten Ionen, sowie zwei Penning-Fallen zum säubern und zur Massenbestimmung der Ionen. Innerhalb dieser Arbeit wurden die Massen von neutronenreichen Xenon- und Radonisotopen (138-146Xe und 223-229Rn) gemessen. Für elf davon wurde zum ersten Mal die Masse direkt bestimmt; 229Rn wurde im Zuge dieses Experimentes sogar erstmalig beobachtet und seine Halbwertszeit konnte zu ungefähr 12 s bestimmt werden. Da die Masse eines Nuklids alle Wechselwirkungen innerhalb des Kerns widerspiegelt, ist sie einzigartig für jedes Nuklid. Eine dieser Wechselwirkungen, die Wechselwirkung zwischen Protonen und Neutronen, führt zum Beispiel zu Deformationen. Das Ziel dieser Arbeit ist eine Verbindung zwischen kollektiven Effekten, wie Deformationen und Doppeldifferenzen von Bindungsenergien, sogenannten deltaVpn-Werten zu finden. Insbesondere in den hier untersuchten Regionen zeigen deltaVpn-Werte ein sehr ungewöhnliches Verhalten, das sich nicht mit einfachen Argumenten deuten lässt. Eine Erklärung könnte das Auftreten von Oktupoldeformationen in diesen Gebieten sein. Nichtsdestotrotz ist eine quantitative Beschreibung von deltaVpn-Werten, die den Effekt von solchen Deformationen berücksichtigt mit modernen Theorien noch nicht möglich.
Resumo:
We describe here a new reversed-phase high-performance liquid chromatography with mass spectrometry detection method for quantifying intact cytokinin nucleotides in human K-562 leukemia cells. Tandem mass spectrometry was used to identify the intracellular metabolites (cytokinin monophosphorylated, diphosphorylated, and triphosphorylated nucleotides) in riboside-treated cells. For the protein precipitation and sample preparation, a trichloroacetic acid extraction method is used. Samples are then back-extracted with diethyl ether, lyophilized, reconstituted, and injected into the LC system. Analytes were quantified in negative selected ion monitoring mode using a single quadrupole mass spectrometer. The method was validated in terms of retention time stabilities, limits of detection, linearity, recovery, and analytical accuracy. The developed method was linear in the range of 1-1,000 pmol for all studied compounds. The limits of detection for the analytes vary from 0.2 to 0.6 pmol.
Resumo:
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.
Resumo:
Collision-induced dissociation (CID) of peptides using tandem mass spectrometry (MS) has been used to determine the identity of peptides and other large biological molecules. Mass spectrometry (MS) is a useful tool for determining the identity of molecules based on their interaction with electromagnetic fields. If coupled with another method like infrared (IR) vibrational spectroscopy, MS can provide structural information, but in its own right, MS can only provide the mass-to-charge (m/z) ratio of the fragments produced, which may not be enough information to determine the mechanism of the collision-induced dissociation (CID) of the molecule. In this case, theoretical calculations provide a useful companion for MS data and yield clues about the energetics of the dissociation. In this study, negative ion electrospray tandem MS was used to study the CID of the deprotonated dipeptide glycine-serine (Gly-Ser). Though negative ion MS is not as popular a choice as positive ion MS, studies by Bowie et al. show that it yields unique clues about molecular structure which complement positive ion spectroscopy, such as characteristic fragmentations like the loss of formaldehyde from the serine residue.2 The increase in the collision energy in the mass spectrometer alters the flexibility of the dipeptide backbone, enabling isomerizations (reactions not resulting in a fragment loss) and dissociations to take place. The mechanism of the CID of Gly-Ser was studied using two computational methods, B3LYP/6-311+G* and M06-2X/6-311++G**. The main pathway for molecular dissociation was analyzed in 5 conformers in an attempt to verify the initial mechanism proposed by Dr. James Swan after examination of the MS data. The results suggest that the loss of formaldehyde from serine, which Bowie et al. indicates is a characteristic of the presence of serine in a protein residue, is an endothermic reaction that is made possible by the conversion of the translational energy of the ion into internal energy as the ion collides with the inert collision gas. It has also been determined that the M06-2X functional¿s improved description of medium and long-range correlation makes it more effective than the B3LYP functional at finding elusive transition states. M06-2X also more accurately predicts the energy of those transition states than does B3LYP. A second CID mechanism, which passes through intermediates with the same m/z ratio as the main pathway for molecular dissociation, but different structures, including a diketopiperazine intermediate, was also studied. This pathway for molecular dissociation was analyzed with 3 conformers and the M06-2X functional, due to its previously determined effectiveness. The results suggest that the latter pathway, which meets the same intermediate masses as the first mechanism, is lower in overall energy and therefore a more likely pathway of dissociation than the first mechanism.
Resumo:
Carnitine is an amino acid derivative that plays a key role in energy metabolism. Endogenous carnitine is found in its free form or esterified with acyl groups of several chain lengths. Quantification of carnitine and acylcarnitines is of particular interest for screening for research and metabolic disorders. We developed a method with online solid-phase extraction coupled to high-performance liquid chromatography and tandem mass spectrometry to quantify carnitine and three acylcarnitines with different polarity (acetylcarnitine, octanoylcarnitine, and palmitoylcarnitine). Plasma samples were deproteinized with methanol, loaded on a cation exchange trapping column and separated on a reversed-phase C8 column using heptafluorobutyric acid as an ion-pairing reagent. Considering the endogenous nature of the analytes, we quantified with the standard addition method and with external deuterated standards. Solid-phase extraction and separation were achieved within 8 min. Recoveries of carnitine and acylcarnitines were between 98 and 105 %. Both quantification methods were equally accurate (all values within 84 to 116 % of target concentrations) and precise (day-to-day variation of less than 18 %) for all carnitine species and concentrations analyzed. The method was used successfully for determination of carnitine and acylcarnitines in different human samples. In conclusion, we present a method for simultaneous quantification of carnitine and acylcarnitines with a rapid sample work-up. This approach requires small sample volumes and a short analysis time, and it can be applied for the determination of other acylcarnitines than the acylcarnitines tested. The method is useful for applications in research and clinical routine.