921 resultados para Scaling and root planning


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars. Objectives: The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated. Material and Methods: Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1) and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p<0.05. Results: No significant differences (p>0.05) were observed between the instruments, regarding the root canal area and dentin wall thickness. Conclusion: Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this study was to evaluate the concentrations of non-structural carbohydrate (NSC) and of total nitrogen (N), as well as, to evaluate the root system in Tanzania-grass pastures fertilized with doses of urea in fall, spring and summer. The experiment was conducted at the Experimental Farm of Iguatemi, Maringa, Parana, Brazil, from March 2007 to March 2008. The experimental design was complete random blocks with subplots and four repetitions. The plots showed doses of N (50, 100 e 150 kg ha(-1) of N) plus the control (no N fertilization), and the subplots the season of the year. Root samples were taken at depths of 0-10, 10-20 and 20-40 cm. Root biomass showed a trend for mass accumulation up to a dosage of 100 kg ha(-1) for all seasons evaluated. Also, about 80% of the root system of Tanzaniagrass plants was found on the 0-10 cm layer for all dosages of N. Nitrogen fertilizer above 100 kg ha(-1) may foster fast forage plant growth reducing its NSC root storage capacity although favoring NSC and total N storage at stem base. NSC and total N concentrations were highest in fall, demonstrating that its usage is greater in spring due to the weather conditions being favorable to plant growth. In the regrowth, the largest reserve of total N was at the 0-10 cm root layer and the largest NSC reserve is at stem base.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this ex vivo study was to evaluate, by scanning electron microscopy (SEM), the presence of gaps at the interface between filling material and three root-end filling materials. Thirty human upper molars disto-buccal roots were instrumented and filled with gutta-percha and eugenol-based sealer. The apicoectomy was performed 2mm from the apex and retrograde cavities were prepared with ultrasonic points (3mm in deep). The samples were divided into three experimental groups (n=10): Group Iwhite mineral trioxide aggregate (MTA); Group IISuper EBA; and Group IIIPortland cement. The root-end filling materials were inserted into the retocavities using a MTA carrier. After 48h, the roots were transversally sectioned in order to obtain the apical 5mm. Next, each specimen was prepared longitudinally with crescent granulation of abrasives water-wet sandpapers in order to expose the filling and root-end filling materials. Then, the specimens were subjected to slow dehydration with silica gel, mounted onto specific stubs and coated with paladium coverage for SEM analysis of the interface between filling and root-end filling materials. The percentage of gaps at the interfacial area was calculated by using Image Tool 3.0 software. Super EBA presented the higher percentage of gaps (1.5 +/- 0.67%), whereas MTA presented the lowest values (0.33 +/- 0.20%; p=0.0004). Despite the statistical differences observed between Super EBA and MTA, all the root-end filling materials presented great adaptation to the filling material, presenting small amount of gaps. SCANNING 36:252-257, 2014. (c) 2013 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of the use of a high-power gallium-aluminum-arsenide diode laser (GaAlAs; 808 nm, 1 W, 20 s, 20 Hz, 10 J) alone or as adjunctive therapy to scaling and root planing in the treatment of induced periodontitis in rats. Periodontitis was induced by placing a ligature around the mandibular first molar of 60 rats. After 7 days, the ligature was removed and the animals were divided into four groups as follows: C (control), no periodontal treatment; SRP, scaling and root planing (SRP); DL, diode laser (DL) irradiation treatment; and SRP/DL, both SRP and DL irradiation treatment. Five animals from each group were euthanized at 7, 15, and 30 days posttreatment. The effectiveness of the treatments was evaluated in the furcation area using histopathological analysis, histometric analysis of alveolar bone loss (ABL), and immunohistochemical detection of tartrate-resistant acid phosphatase (TRAP), runt-related transcription factor 2 (RUNX2), and osteocalcin (OCN). DL, alone or in combination with adjunctive therapy to SRP in the treatment of experimental periodontitis, resulted in a decreased local inflammatory response. At 7-days posttreatment, the DL and SRP/DL groups had fewer TRAP-positive cells and more RUNX2-positive cells. There was greater OCN immunolabeling in the DL group than in the C and SRP groups at 15 days. There was less ABL in the DL and SRP/DL groups at 15 and 30 days. In conclusion, DL was effective in the treatment of ligature-induced periodontitis in rats, both when used alone and when used as adjunctive therapy to SRP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the insertion technique for resin cement and mechanical cycling on the bond strength between fiber posts and root dentin.Materials and Methods: Sixty-four single-rooted bovine teeth were endodontically prepared to receive glass-fiber posts. The insertion of cement into the root canal was performed using one of the following techniques: POS, insertion with the post; LEN, the use of a lentulo-type drill; EXP, insertion with a straight-tip explorer; or CEN, the use of a Centrix syringe. Half of the specimens were mechanically cycled. All specimens were sectioned into slices of 1.8 mm for the push-out test and 0.5 mm for analysis of the cement layer quality.Results: The insertion technique affected the interaction between factors (bond strength and mechanical cycling; p < 0.0001). Insertion of the Centrix syringe after mechanical cycling showed the highest bond values (13.6 +/- 3.2 MPa). Group-to-group comparisons for baseline and cycled conditions indicated that mechanical cycling significantly influenced the bond strength (p < 0.0001) of the POS and CEN groups. The quality of the cement layer did not differ between the techniques when evaluated in the middle (p = 0.0612) and cervical (p = 0.1119) regions, but did differ in the apical region (p = 0.0097), where the CEN group had better layer quality for the two conditions tested (baseline and cycled).Conclusion: The use of the Centrix syringe improved the homogeneity of the cement layer, reducing the defects in the layer and increasing adhesive strength values to dentin, even after mechanical cycling.