950 resultados para Scaling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

"UILU-ENG 84 1703"--Cover.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On cover: Saline water conversion research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Project No. 1426, Task No. 142612."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Contract no. DA-30-069-ORD-3443. ARPA order no. 253-62."

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding, and controlling, the conditions under which calcite precipitates within geothermal energy production systems is a key step in maintaining production efficiency. In this study, I apply methods of bulk and clumped isotope thermometry to an operating geothermal energy facility in northern Nevada to see how those methods can better inform the facility owner, AltaRock Energy, Inc., about the occurrence of calcite scale in their power plant. I have taken water samples from five production wells, the combined generator effluent, shallow cold-water wells, monitoring wells, and surface water. I also collected calcite scale samples from within the production system. Water samples were analyzed for stable oxygen isotope composition (d18O). Calcite samples were analyzed for stable oxygen and carbon (d13C) composition, and clumped isotope composition (D47). With two exceptions, the water compositions are very similar, likely indicating common origin and a well-mixed hydrothermal system. The calcite samples are likewise similar to one another. Apparent temperatures calculated from d18O values of water and calcite are lower than those recorded for the system. Apparent temperatures calculated from D47 are several degrees higher than the recorded well temperatures. The lower temperatures from the bulk isotope data are consistent with temperatures that could be expected during a de-pressurization of the production system, which would cause boiling in the pipes, a reduction in system temperature, and rapid precipitation of calcite scale. However, the high apparent temperature indicated by the D47 data suggests that the calcite is depleted in clumped isotopes given the known temperature of the system, which is inconsistent with this hypothesis. This depletion could instead result from disequilibrium isotopic fractionation during the aforementioned boil events, which would make both the apparent d18O-based and D47-based temperatures unrepresentative of the actual water temperature. This research can help improve our understanding of how isotopic analyses can better inform us about the movement of water through geothermal systems of the past and how it now moves through modern systems. Increased understanding of water movement in these systems could potentially allow for more efficient utilization of geothermal energy as a renewable resource.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scaling of decoherence rates with qubit number N is studied for a simple model of a quantum computer in the situation where N is large. The two state qubits are localized around well-separated positions via trapping potentials and vibrational centre of mass motion of the qubits occurs. Coherent one and two qubit gating processes are controlled by external classical fields and facilitated by a cavity mode ancilla. Decoherence due to qubit coupling to a bath of spontaneous modes, cavity decay modes and to the vibrational modes is treated. A non-Markovian treatment of the short time behaviour of the fidelity is presented, and expressions for the characteristic decoherence time scales obtained for the case where the qubit/cavity mode ancilla is in a pure state and the baths are in thermal states. Specific results are given for the case where the cavity mode is in the vacuum state and gating processes are absent and the qubits are in (a) the Hadamard state (b) the GHZ state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the European lesser-spotted dogfish Scyliorhinus canicula, rectal gland mass in mg (M-Rg) followed the allometric relationship: M-Rg = 1.15 M-0.68, where M is body mass (g). The concept of allometric scaling is an important consideration in studies investigating the function Of osmoregulatory organs. (C) 2003 the Fisheries Society of the British Isles.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

0We study the exact solution for a two-mode model describing coherent coupling between atomic and molecular Bose-Einstein condensates (BEC), in the context of the Bethe ansatz. By combining an asymptotic and numerical analysis, we identify the scaling behaviour of the model and determine the zero temperature expectation value for the coherence and average atomic occupation. The threshold coupling for production of the molecular BEC is identified as the point at which the energy gap is minimum. Our numerical results indicate a parity effect for the energy gap between ground and first excited state depending on whether the total atomic number is odd or even. The numerical calculations for the quantum dynamics reveals a smooth transition from the atomic to the molecular BEC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that interesting multigate circuits can be constructed using a postselected controlled-sign gate that works with a probability (1/3)(n), where n-1 is the number of controlled-sign gates in the circuit, rather than (1/9)(n-1), as would be expected from a sequence of such gates. We suggest some quantum information tasks which could be demonstrated using these circuits, such as parity checking and cluster-state computation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, very massive compact stellar systems have been discovered in the intracluster regions of galaxy clusters and in the nuclear regions of late-type disk galaxies. It is unclear how these compact stellar systems - known as ultracompact dwarf (UCD) galaxies or nuclear clusters (NCs) - form and evolve. By adopting a formation scenario in which these stellar systems are the product of multiple merging of star clusters in the central regions of galaxies, we investigate, numerically, their physical properties. We find that physical correlations among velocity dispersion, luminosity, effective radius, and average surface brightness in the stellar merger remnants are quite different from those observed in globular clusters. We also find that the remnants have triaxial shapes with or without figure rotation, and these shapes and their kinematics depend strongly on the initial number and distribution of the progenitor clusters. These specific predictions can be compared with the corresponding results of ongoing and future observations of UCDs and NCs, thereby providing a better understanding of the origin of these enigmatic objects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patient discomfort is one reason for poor compliance with supportive periodontal therapy (SPT). The aim of this study was to compare the levels of discomfort during SPT, using the Vector (TM) system and treatment with a conventional ultrasonic scaler. Methods: Forty-six patients with an SPT programme were debrided using both the Vector (TM) system and a conventional piezo-electric scaler (Sirona (TM)) in a split mouth design. A visual analogue scale was used to evaluate of pain scores upon completion of treatment. A verbal response scale(VRS) was used to assess discomfort, vibration and noise associated with the scaling system, as well as the volume and taste of the coolant used by these systems. Results: Patients instrumented with the Vector (TM) system experienced approximately half the amount of pain compared with the conventional ultrasonic scaling system. The VRS showed that the Vector (TM) system caused less discomfort than the conventional ultrasonic scaling system when assessed for pain, vibration, noise and volume of coolant. These findings were all statistically significant. There was, however, no statistically significant difference between the two systems when assessed for taste. Conclusion: During SPT the Vector (TM) system caused reduced discomforting sensations compared with conventional methods and may be useful in improving compliance with SPT programmes.