943 resultados para RR variability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores analytically the contemporary pottery-making community of Pereruela (north-west Spain) that produces cooking pots from a mixture of red clay and kaolin. Analyses by different techniques (XRF, NAA, XRD, SEM and petrography) showed an extremely high variability for cooking ware pottery produced in a single production centre, by the same technology and using local clays. The main source of chemical variation is related to the use of different red clays and the presence of non-normally distributed inclusions of monazite. These two factors induce a high chemical variability, not only in the output of a single production centre, but even in the paste of a single pot, to an extent to which chemical compositions from one"workshop", or even one"pot", could be classified as having different provenances. The implications for the chemical characterization and for provenance studies of archaeological ceramics are addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Describimos la distribución espacial de individuos de Pinus uncinata clasificados según su forma de crecimiento y tamaño en dos ecotonos poco perturbados del límite altitudinal del árbol situados en los Pirineos Centrales españoles (Ordesa, O; Tessó, T). En cada sitio situamos una parcela rectangular (30 140 m), que incluía los límites del árbol y del bosque, y cuyo lado mayor seguía el gradiente altitudinal. En ambos sitios, los individuos vivos eran más grandes y tenían un mayor número de cohortes de acículas pendiente abajo. La distribución de las clases de individuos según su forma de crecimiento y tamaño en el sitio O seguía una secuencia de mayor tamaño pendiente abajo, desde abundantes individuos policórmicos arbustivos (krummholz) con pocas cohortes de acículas (1-3) hasta individuos arbóreos mayores unicórmicos con varias cohortes de acículas (4-12). Por el contrario, los cambios estructurales en el ecotono del sitio T fueron graduales y no siguieron de forma tan clara dicha secuencia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sagitta setosa is a neritic Chaetognath exhibiting a discontinuous geographic distribution. To assess the influence of its discontinuous geographic distribution on morphometric variability between isolated populations, we conducted a biometric study of S. setosa from three different locations: Goteborg and Plymouth (North Atlantic) and Barcelona ( Western Mediterranean). Out results do indicate some disparity between the populations that is reflected not in size differences, largely determined by water temperature, but in shape (body proportions).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a simulation based on a pharmacokinetic model we demonstrated that increasing the erythropoiesis stimulating agents (ESAs) half-life or shortening their administration interval decreases hemoglobin variability. The benefit of reducing the administration interval was however lessened by the variability induced by more frequent dosage adjustments. The purpose of this study was to analyze the reticulocyte and hemoglobin kinetics and variability under different ESAs and administration intervals in a collective of chronic hemodialysis patients. METHODS: The study was designed as an open-label, randomized, four-period cross-over investigation, including 30 patients under chronic hemodialysis at the regional hospital of Locarno (Switzerland) in February 2010 and lasting 2 years. Four subcutaneous treatment strategies (C.E.R.A. every 4 weeks Q4W and every 2 weeks Q2W, Darbepoetin alfa Q4W and Q2W) were compared with each other. The mean square successive difference of hemoglobin, reticulocyte count and ESAs dose was used to quantify variability. We distinguished a short- and a long-term variability based respectively on the weekly and monthly successive difference. RESULTS: No difference was found in the mean values of biological parameters (hemoglobin, reticulocytes, and ferritin) between the 4 strategies. ESAs type did not affect hemoglobin and reticulocyte variability, but C.E.R.A induced a more sustained reticulocytes response over time and increased the risk of hemoglobin overshooting (OR 2.7, p = 0.01). Shortening the administration interval lessened the amplitude of reticulocyte count fluctuations but resulted in more frequent ESAs dose adjustments and in amplified reticulocyte and hemoglobin variability. Q2W administration interval was however more favorable in terms of ESAs dose, allowing a 38% C.E.R.A. dose reduction, and no increase of Darbepoetin alfa. CONCLUSIONS: The reticulocyte dynamic was a more sensitive marker of time instability of the hemoglobin response under ESAs therapy. The ESAs administration interval had a greater impact on hemoglobin variability than the ESAs type. The more protracted reticulocyte response induced by C.E.R.A. could explain both, the observed higher risk of overshoot and the significant increase in efficacy when shortening its administration interval.Trial registrationClinicalTrials.gov NCT01666301.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is evidence across several species for genetic control of phenotypic variation of complex traits, such that the variance among phenotypes is genotype dependent. Understanding genetic control of variability is important in evolutionary biology, agricultural selection programmes and human medicine, yet for complex traits, no individual genetic variants associated with variance, as opposed to the mean, have been identified. Here we perform a meta-analysis of genome-wide association studies of phenotypic variation using ∼170,000 samples on height and body mass index (BMI) in human populations. We report evidence that the single nucleotide polymorphism (SNP) rs7202116 at the FTO gene locus, which is known to be associated with obesity (as measured by mean BMI for each rs7202116 genotype), is also associated with phenotypic variability. We show that the results are not due to scale effects or other artefacts, and find no other experiment-wise significant evidence for effects on variability, either at loci other than FTO for BMI or at any locus for height. The difference in variance for BMI among individuals with opposite homozygous genotypes at the FTO locus is approximately 7%, corresponding to a difference of ∼0.5 kilograms in the standard deviation of weight. Our results indicate that genetic variants can be discovered that are associated with variability, and that between-person variability in obesity can partly be explained by the genotype at the FTO locus. The results are consistent with reported FTO by environment interactions for BMI, possibly mediated by DNA methylation. Our BMI results for other SNPs and our height results for all SNPs suggest that most genetic variants, including those that influence mean height or mean BMI, are not associated with phenotypic variance, or that their effects on variability are too small to detect even with samples sizes greater than 100,000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated possible relations among four common neonatal manifestations of diabetic pregnancy (macrosomia, hypoglycemia, hypocalcemia, jaundice) and four enzyme polymorphisms (PGM1, ADA, AK1, ACP1 in a sample of infants born of diabetic mothers. The pattern of associations observed between the two sets of variables is consistent with known differences in enzymatic activity within phenotypes of each system, suggesting that low enzymatic activity may have unfavorable effects on fetal development and on adaptability of the neonate to the extrauterine environment, Some of the polymorphic enzymes studied influence fetal growth in normal pregnancy as well. Analysis of relations between genetic polymorphisms and the clinical pattern of common diseases may provide a better understanding of the genetic basis of the clinical variability of diseases within and between human populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The physical-chemical testing of fly ashes indicates that, under normal operating conditions, a low variability of results can be expected from a particular generating plant unit. However, unannounced changes in coal source and/or plant operations do occur and they may result in an ash with undesirable properties. Since these properties can be detected by physical-chemical testing, it is recommended that this testing be performed on a lot-by-lot basis when a plant is supplying fly ash to a construction project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two species of wild potato Solanum commersonii, subspecies commersonii and malmeanum, and S. chacoense, subspecies muelleri occur in southern Brazil. Their rusticity and easy adaptation to extreme climatic conditions make them valuable for breeding programs. The objective of this work was to analyze the isoenzymatic variability of 113 clones of wild potato subspecies. They were collected and maintained at Embrapa-Centro de Pesquisa Agropecuária de Clima Temperado, at Pelotas, RS, Brazil. Enzymes involved in energetic (group I) or in peripherical (group II) metabolism constituted the material used. Polyacrylamide horizontal gel electrophoresis was used to analyze peroxidase, aspartate transaminase, phosphoglucomutase and isocitrate dehydrogenase isoenzymes. Solanum spp. has considerable genetic variability for isoenzymatic patterns. Cluster analysis classified the clones into 51 subgroups, based on electrophoretic variants of group I enzymes, and into 89, when group II enzyme variants were added. Genotypic differentiation of S. chacoense muelleri in relation to S. commersonii commersonii and S. commersonii malmeanum is evident when expressed through similarity and cluster analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.