871 resultados para Pulsating heat pipe


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding how plants sense and respond to heat stress is central to improve crop tolerance and productivity. Recent findings in Physcomitrella patensdemonstrated that the controlled passage of calcium ions across the plasma membrane regulates the heat shock response (HSR). To investigate the effect of membrane lipid composition on the plant HSR, we acclimated P. patens to a slightly elevated yet physiological growth temperature and analysed the signature of calcium influx under a mild heat shock. Compared to tissues grown at 22°C, tissues grown at 32°C had significantly higher overall membrane lipid saturation level and, when submitted to a short heat shock at 35°C, displayed a noticeably reduced calcium influx and a consequent reduced heat shock gene expression. These results show that temperature differences, rather than the absolute temperature, determine the extent of the plant HSR and indicate that membrane lipid composition regulates the calcium-dependent heat-signaling pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiative heat exchange at the nanoscale presents a challenge for several areas due to its scope and nature. Here, we provide a thermokinetic description of microscale radiative energy transfer including phonon-photon coupling manifested through a non-Debye relaxation behavior. We show that a lognormal-like distribution of modes of relaxation accounts for this non-Debye relaxation behavior leading to the thermal conductance. We also discuss the validity of the fluctuation-dissipation theorem. The general expression for the thermal conductance we obtain fits existing experimental results with remarkable accuracy. Accordingly, our approach offers an overall explanation of radiative energy transfer through micrometric gaps regardless of geometrical configurations and distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined Heat and Power (CHP) refers to the onsite production of electricity and thermal energy from the same fuel source. Integrating power and thermal energy production is more efficient than separate generating systems and used in the right situation can yield several benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined Heat and Power (CHP) refers to the onsite production of electricity and thermal energy from the same fuel source. Integrating power and thermal energy production is more efficient than separate generating systems and used in the right situation can yield several benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of photosynthetic organisms to adapt to increases in environmental temperatures is becoming more important with climate change. Heat stress is known to induce heat-shock proteins (HSPs) many of which act as chaperones. Traditionally, it has been thought that protein denaturation acts as a trigger for HSP induction. However, increasing evidence has shown that many stress events cause HSP induction without commensurate protein denaturation. This has led to the membrane sensor hypothesis where the membrane's physical and structural properties play an initiating role in the heat shock response. In this review, we discuss heat-induced modulation of the membrane's physical state and changes to these properties which can be brought about by interaction with HSPs. Heat stress also leads to changes in lipid-based signaling cascades and alterations in calcium transport and availability. Such observations emphasize the importance of membranes and their lipids in the heat shock response and provide a new perspective for guiding further studies into the mechanisms that mediate cellular and organismal responses to heat stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli selvittää, kuinka kohdeyrityksessä nykyhetkellä pitkältiräätälöitynä tuotetut putkilämmönvaihtimet voitaisiin standardisoida, jotta pystyttäisiin kohdistamaan resursseja oikein ja parantamaan siten yrityksen taloudellista suorituskykyä. Tutkimuksen edetessä määräävimmäksi tekijäksi työn tuloksia ajatellen nousi taloudellinen standardisointiaste, jonka perusteeksi kohdeyrityksen putkilämmönvaihtimissa valittiin standardisoitu suunnitteluohjeisto. Suunnitteluohjeiston lisäksi tuotestandardiin liitettiin ehdotus toimintapojen automatisoimisesta parametrisen valintataulukon sekä sähköisen manuaalin avulla. Työssä tuotestandardisointia tarkastellaan rationalisointi-investointina ja sen kannattavuutta on tarkasteltu investointilaskelmien sekä herkkyys analyysin avulla. Alkuarvot investointilaskelmissa perustuvat työssä yhdelle putkilämmönvaihtimelletoteutettuun tuotestandardisointitapaan, jos tätä tapaa käytettäisiin jatkossa kaikkiin kyseisen yksikön putkilämmönvaihtimiin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In plants, the heat stress response (HSR) is highly conserved and involves multiple pathways, regulatory networks and cellular compartments. At least four putative sensors have recently been proposed to trigger the HSR. They include a plasma membrane channel that initiates an inward calcium flux, a histone sensor in the nucleus, and two unfolded protein sensors in the endoplasmic reticulum and the cytosol. Each of these putative sensors is thought to activate a similar set of HSR genes leading to enhanced thermotolerance, but the relationship between the different pathways and their hierarchical order is unclear. In this review, we explore the possible involvement of different thermosensors in the plant response to warming and heat stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proper and rapid diagnosis of orthopedic device-related infection is important for successful treatment. Sonication has been shown to improve the diagnostic performance. We hypothesized that the combination of sonication with a novel method called microcalorimetry will further improve and accelerate the diagnosis of implant infection. We prospectively included 39 consecutive patients (mean age 59 years, 62% males) at our institution from whom 29 orthopedic prostheses and 10 osteosynthesis material were explanted. The explanted device was sonicated. The resulting sonication fluid was analyzed using microcalorimetry. Using standardized criteria to define orthopedic device-related infection, 12 cases (31%) were defined as infected. In all, positive periprosthetic tissue cultures were found. The sensitivity and specificity of microcalorimetry of sonication fluid were 100% and 97%, respectively. Mean time to detection, defined as time to reach a rising heat flow signal of 20 µW measured after equilibiration needed to get accurate measurement, was 10.9 h. In summary, microcalorimetry of sonication fluid is a reliable and a fast method in detecting the presence of microorganisms in orthopedic device-related infection. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1700-1703, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In eukaryotes, heat shock protein 90 (Hsp90) is an essential ATP-dependent molecular chaperone that associates with numerous client proteins. HtpG, a prokaryotic homolog of Hsp90, is essential for thermotolerance in cyanobacteria, and in vitro it suppresses the aggregation of denatured proteins efficiently. Understanding how the non-native client proteins bound to HtpG refold is of central importance to comprehend the essential role of HtpG under stress. Here, we demonstrate by yeast two-hybrid method, immunoprecipitation assays, and surface plasmon resonance techniques that HtpG physically interacts with DnaJ2 and DnaK2. DnaJ2, which belongs to the type II J-protein family, bound DnaK2 or HtpG with submicromolar affinity, and HtpG bound DnaK2 with micromolar affinity. Not only DnaJ2 but also HtpG enhanced the ATP hydrolysis by DnaK2. Although assisted by the DnaK2 chaperone system, HtpG enhanced native refolding of urea-denatured lactate dehydrogenase and heat-denatured glucose-6-phosphate dehydrogenase. HtpG did not substitute for DnaJ2 or GrpE in the DnaK2-assisted refolding of the denatured substrates. The heat-denatured malate dehydrogenase that did not refold by the assistance of the DnaK2 chaperone system alone was trapped by HtpG first and then transferred to DnaK2 where it refolded. Dissociation of substrates from HtpG was either ATP-dependent or -independent depending on the substrate, indicating the presence of two mechanisms of cooperative action between the HtpG and the DnaK2 chaperone system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to obtain prevalence estimates of cloudy vaginal mucus in artificially inseminated Holstein cows raised under intense heat, in order to assess the effect of meteorological conditions on its occurrence during estrus and to determine its effect on conception rate. In a first study, an association was established between the occurrence of cloudy vaginal mucus during estrus and the conception rate of inseminated cows (18,620 services), raised under intense heat (mean annual temperature of 22°C), at highly technified farms, in the arid region of northern Mexico. In a second study, data from these large dairy operations were used to assess the effect of meteorological conditions throughout the year on the occurrence of cloudy vaginal mucus during artificial insemination (76,899 estruses). The overall rate of estruses with cloudy vaginal mucus was 21.4% (16,470/76,899; 95% confidence interval = 21.1-21.7%). The conception rate of cows with clean vaginal mucus was higher than that of cows with abnormal mucus (30.6 vs. 22%). Prevalence of estruses with cloudy vaginal mucus was strongly dependent on high ambient temperature and markedly higher in May and June. Acceptable conception rates in high milk-yielding Holstein cows can only be obtained with cows showing clear and translucid mucus at artificial insemination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön päämääränä on tehdä prosessiteollisuuden tarpeisiin Excel-taulukkolaskentaohjelmassa toimiva putkilämmönsiirtimen mitoitusohjelma. Prosessiteollisuudessa lämmönvaihtimien toimintaympäristöt ja olosuhteet vaihtelevat merkittävästi ja niinpä jokaisen vaihtimen suunnittelu ja mitoitus on toteutettava tapauskohtaisesti. Työssä käsitellään rekuperatiivisen ristivirtaputkilämmönvaihtimen yleinen lämpötekninen mitoitus sisältäen putken sisäpinnalle tapahtuvan mahdollisen lauhtumisen. Mitoitettava vaihdinkoostuu pystysuorista putkista, joissa lämmin ja kostea ilma virtaa putkien sisäpuolella ja kylmä kuiva ilma vaippapuolella vaakasuoraan. Vaihdinmateriaalina käytetään ruostumatonta AISI 304 -tai haponkestävää AISI 316 terästä. Kuuman ilman tila vaihtelee tarkasteltavan kohteen mukaan. Paperiteollisuuden kuivausyksiköiltä poistuva ilma on usein lämmintä ja kosteaa, ja infrakuivaimilta poistuva ilma on kuumaa. Mitoitettavalle lämmönvaihtimelle tulevan kuuman ilman lämpötila tapauksesta riippuen voi vaihdella 30°C, maksimissaan +300°C:een saakka, vesisisällön ollessa välillä 0,010...0,200 kg/kg ki tai jopa tämän ylikin. Vaihtimen mitoitus perustuu energiataseyhtälöiden käyttöön. Laskennassa määritetään vaihtimen pintalämpötila sekä mahdollinen kostean ilman lauhtuminen putken sisäpinnalle. Lisäksi teoria käsittää molempien virtausten tilanmuutosten laskennan. Työssä on esitetty esimerkkilaskelma, jossa on laskettu ilma- kostea ilma lämmönsiirrinkonstruktio. Esimerkissä on tarkasteltu vaihtimen hyötysuhdetta, virtausten lämpö- ja kosteuskäyttäytymistä ulkoilman lämpötilan funktiona. Ohjelmasta saadaan tulostettua mitoitettavanvaihtimen dimensiot; putkien lukumäärät syvyys- ja pituussuunnassa sekä kokonaisputkilukumäärä, putkien väliset etäisyydet toisiinsa nähden sekä syvyys, että pituussuunnassa, putkipituus ja putken sisä- ja ulkohalkaisijat. Nämä tiedot suunnittelija itse syöttää ohjelmalle alkuarvoina. Laskettuna tietona ohjelma antaa molempien virtausten poistolämpötilat, kuuman ilman poistuvan absoluuttisen kosteuden, kondenssivesimäärän, vaihtimen tehon ja painehäviöt vaippa- ja putkipuolelle. Lisäksi ohjelma laskee kuuman ilman ominaisentalpiat vaihtimen sisään- ja ulostulossa. Tämä mahdollistaa ilman tilapisteiden piirtämisen Mollier-piirrokseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cigar and pipe smoking are considered risk factors for head and neck cancers, but the magnitude of effect estimates for these products has been imprecisely estimated. By using pooled data from the International Head and Neck Cancer Epidemiology (INHANCE) Consortium (comprising 13,935 cases and 18,691 controls in 19 studies from 1981 to 2007), we applied hierarchical logistic regression to more precisely estimate odds ratios and 95% confidence intervals for cigarette, cigar, and pipe smoking separately, compared with reference groups of those who had never smoked each single product. Odds ratios for cigar and pipe smoking were stratified by ever cigarette smoking. We also considered effect estimates of smoking a single product exclusively versus never having smoked any product (reference group). Among never cigarette smokers, the odds ratio for ever cigar smoking was 2.54 (95% confidence interval (CI): 1.93, 3.34), and the odds ratio for ever pipe smoking was 2.08 (95% CI: 1.55, 2.81). These odds ratios increased with increasing frequency and duration of smoking (Ptrend ≤ 0.0001). Odds ratios for cigar and pipe smoking were not elevated among ever cigarette smokers. Head and neck cancer risk was elevated for those who reported exclusive cigar smoking (odds ratio = 3.49, 95% CI: 2.58, 4.73) or exclusive pipe smoking (odds ratio = 3.71, 95% CI: 2.59, 5.33). These results suggest that cigar and pipe smoking are independently associated with increased risk of head and neck cancers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The studies of flow phenomena, heat and mass transfer in microchannel reactors are beneficial to estimate and evaluate the ability of microchannel reactors to be operated for a given process reaction such as Fischer-Tropsch synthesis. The flow phenomena, for example, the flow regimes and flow patterns in microchannel reactors for both single phase and multiphase flow are affected by the configuration of the flow channel. The reviews of the previous works about the analysis of related parameters that affect the flow phenomena are shown in this report. In order to predict the phenomena of Fischer-Tropsch synthesis in microchannel reactors, the 3-dimensional computational fluid dynamic simulation with commercial software package FLUENT was done to study the flow phenomena and heat transfer for gas phase Fischer-Tropsch products flow in rectangular microchannel with hydraulic diameter 500 ¿m and length 15 cm. Numerical solution with slip boundary condition was used in the simulation and the flowphenomena and heat transfer were determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salt and heat stresses, which are often combined in nature, induce complementing defense mechanisms. Organisms adapt to high external salinity by accumulating small organic compounds known as osmolytes, which equilibrate cellular osmotic pressure. Osmolytes can also act as "chemical chaperones" by increasing the stability of native proteins and assisting refolding of unfolded polypeptides. Adaptation to heat stress depends on the expression of heat-shock proteins, many of which are molecular chaperones, that prevent protein aggregation, disassemble protein aggregates, and assist protein refolding. We show here that Escherichia coli cells preadapted to high salinity contain increased levels of glycine betaine that prevent protein aggregation under thermal stress. After heat shock, the aggregated proteins, which escaped protection, were disaggregated in salt-adapted cells as efficiently as in low salt. Here we address the effects of four common osmolytes on chaperone activity in vitro. Systematic dose responses of glycine betaine, glycerol, proline, and trehalose revealed a regulatory effect on the folding activities of individual and combinations of chaperones GroEL, DnaK, and ClpB. With the exception of trehalose, low physiological concentrations of proline, glycerol, and especially glycine betaine activated the molecular chaperones, likely by assisting local folding in chaperone-bound polypeptides and stabilizing the native end product of the reaction. High osmolyte concentrations, especially trehalose, strongly inhibited DnaK-dependent chaperone networks, such as DnaK+GroEL and DnaK+ClpB, likely because high viscosity affects dynamic interactions between chaperones and folding substrates and stabilizes protein aggregates. Thus, during combined salt and heat stresses, cells can specifically control protein stability and chaperone-mediated disaggregation and refolding by modulating the intracellular levels of different osmolytes.