914 resultados para Power Network in Loop Simulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power systems require a reliable supply and good power quality. The impact of power supply interruptions is well acknowledged and well quantified. However, a system may perform reliably without any interruptions but may have poor power quality. Although poor power quality has cost implications for all actors in the electrical power systems, only some users are aware of its impact. Power system operators are much attuned to the impact of low power quality on their equipment and have the appropriate monitoring systems in place. However, over recent years certain industries have come increasingly vulnerable to negative cost implications of poor power quality arising from changes in their load characteristics and load sensitivities, and therefore increasingly implement power quality monitoring and mitigation solutions. This paper reviews several historical studies which investigate the cost implications of poor power quality on industry. These surveys are largely focused on outages, whilst the impact of poor power quality such as harmonics, short interruptions, voltage dips and swells, and transients is less well studied and understood. This paper examines the difficulties in quantifying the costs of poor power quality, and uses the chi-squared method to determine the consequences for industry of power quality phenomenon using a case study of over 40 manufacturing and data centres in Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The expansion of a magnetized high-pressure plasma into a low-pressure ambient medium is examined with particle-in-cell simulations. The magnetic field points perpendicular to the plasma's expansion direction and binary collisions between particles are absent. The expanding plasma steepens into a quasi-electrostatic shock that is sustained by the lower-hybrid (LH) wave. The ambipolar electric field points in the expansion direction and it induces together with the background magnetic field a fast E cross B drift of electrons. The drifting electrons modify the background magnetic field, resulting in its pile-up by the LH shock. The magnetic pressure gradient force accelerates the ambient ions ahead of the LH shock, reducing the relative velocity between the ambient plasma and the LH shock to about the phase speed of the shocked LH wave, transforming the LH shock into a nonlinear LH wave. The oscillations of the electrostatic potential have a larger amplitude and wavelength in the magnetized plasma than in an unmagnetized one with otherwise identical conditions. The energy loss to the drifting electrons leads to a noticeable slowdown of the LH shock compared to that in an unmagnetized plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies have shown that large geographical spreading can reduce the wind power variability and smooth production. It is frequently assumed that storage and interconnection can manage wind power variability and are totally flexible. However, constraints do exist. In the future more and more electricity will be provided by renewable energy sources and more electricity interconnectors will be built between European Union (EU) countries, as outlines in many of the Projects of Common Interests. It is essential to understand the correlation of wind generation throughout Europe considering power system constraints. In this study the spatial and temporal correlation of wind power production across several countries is examined in order to understand how “the wind ‘travels’ across Europe”. Three years of historical hourly wind power generation from ten EU countries is analysed to investigate the geographic diversity and time scales influence on correlation of wind power variations. Results are then compared with two other studies and show similar general characteristics of correlation between EU country pairs to identify opportunities for storage optimisation, power system operations, and trading.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Illinois State Water Survey

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lake Ovan with about 9 hectares is regarded a semi-shallow lake with an average depth 5.2 meter. It is situated in Ghazvin Province, with a 1910 m high in mountainous regime. A monthly sampling was done at 3 stations studying the physicochemical and biological parameters in water and sediment at the Lake for a year. The temperature annual was measured 12.3°C and other parameters are pH as 8.8, oxygen 10, with total mean phosphate and nitrate as 0.14 & 0.8 mg/lit respectively. The chl.a mean was also measured 1.94 mg/lit. The ratio of N to P was calculated as 1:59, indicating a limiting factor for growth. Considering the trophic statues of the lake taking into account as above parameters, it is a mesotrophic lake with medium trophy. Altogether, 53 phytoplankton species were identified mostly diatoms, green algae and cyanobacteria. Although, 14 zooplankton species were identified with daphnia dominating the group. Macrobenthoses were also surveyed and 11 families were identified comprising mainly by Annelids, Gastropod, Bivalves and Insect Larvae. Other organisms were 2 dominate water plant including Phragmites australis covering at the edge of the lake and potamogeton sp in the inner parts, and also 2 fish species, common carp and Pike Perch. The diversity Shannon—Wiener index was calculated for main taxa groups with all figures lower than 3. Regarding the fish potential production of the lake based on Bramic & Lemke and morphoedophic index, it was calculated to be 20.4 kg/ha fish and a total of about 150 kg for the entire lake.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sporulation is a process in which some bacteria divide asymmetrically to form tough protective endospores, which help them to survive in a hazardous environment for a quite long time. The factors which can trigger this process are diverse. Heat, radiation, chemicals and lacking of nutrition can all lead to the formation of endospores. This phenomenon will lead to low productivity during industrial production. However, the sporulation mechanism in a spore-forming bacterium, Clostridium theromcellum, is still unclear. Therefore, if a regulation network of sporulation can be built, we may figure out ways to inhibit this process. In this study, a computational method is applied to predict the sporulation network in Clostridium theromcellum. A working sporulation network model with 40 new predicted genes and 4 function groups is built by using a network construction program, CINPER. 5 sets of microarray expression data in Clostridium theromcellum under different conditions have been collected. The analysis shows the predicted result is reasonable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the problem of coordinated trading of wind and photovoltaic systems in order to find the optimal bid to submit in a pool-based electricity market. The coordination of wind and photovoltaic systems presents uncertainties not only due to electricity market prices, but also with wind and photovoltaic power forecast. Electricity markets are characterized by financial penalties in case of deficit or excess of generation. So, the aim o this work is to reduce these financial penalties and maximize the expected profit of the power producer. The problem is formulated as a stochastic linear programming problem. The proposed approach is validated with real data of pool-based electricity market of Iberian Peninsula.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This PhD dissertation envisages the design of innovative power converters exploiting WBG devices to get state-of-the-art performance in products intended for industrial applications of automotive field. The collaborations with different specialized companies, provided the opportunity to access commercially-available state-of-the-art SiC and GaN technologies and the possibility to realize innovative converter prototypes. Concerning SiC technology, the complete design of a $350kW$ Battery Emulator instrument in collaboration with a company leader in the automotive testing sector, was carried out from scratch exploiting state-of-the-art SiC power-modules, planar magnetics and top-notch MCU technologies. Discrete high-voltage GaN switches were exploited in the Power Supplies design for automotive charger application to target improved performances compared to the market state-of-the-art. Specifically, two high-efficiency prototypes, an AC/DC converter and a DC/DC converter of $7.5kW$, have been realized for this purpose. To further investigate the characteristics of state-of-the-art GaN power devices two measurement set-ups have been designed. In particular, the trapping phenomenon causing the collapse of drain current during ON-state with a consequent degradation of ON-resistance has been analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the aim of heading towards a more sustainable future, there has been a noticeable increase in the installation of Renewable Energy Sources (RES) in power systems in the latest years. Besides the evident environmental benefits, RES pose several technological challenges in terms of scheduling, operation, and control of transmission and distribution power networks. Therefore, it raised the necessity of developing smart grids, relying on suitable distributed measurement infrastructure, for instance, based on Phasor Measurement Units (PMUs). Not only are such devices able to estimate a phasor, but they can also provide time information which is essential for real-time monitoring. This Thesis falls within this context by analyzing the uncertainty requirements of PMUs in distribution and transmission applications. Concerning the latter, the reliability of PMU measurements during severe power system events is examined, whereas for the first, typical configurations of distribution networks are studied for the development of target uncertainties. The second part of the Thesis, instead, is dedicated to the application of PMUs in low-inertia power grids. The replacement of traditional synchronous machines with inertia-less RES is progressively reducing the overall system inertia, resulting in faster and more severe events. In this scenario, PMUs may play a vital role in spite of the fact that no standard requirements nor target uncertainties are yet available. This Thesis deeply investigates PMU-based applications, by proposing a new inertia index relying only on local measurements and evaluating their reliability in low-inertia scenarios. It also develops possible uncertainty intervals based on the electrical instrumentation currently used in power systems and assesses the interoperability with other devices before and after contingency events.