909 resultados para PEAK TORQUE
Resumo:
The reduction of the power loss generated in mechanical transmissions and the use of low friction biodegradable lubricants has been attracting considerable attention in recent times. Therefore, it is necessary to develop methods to test and evaluate the performance of such lubricants and compare them with conventional ones. In this sense, a Four-Ball Machine was modified allowing the test of rolling bearings. A 51107 thrust ball bearing was used to test two different greases and the corresponding base oils. Friction torque and operating temperatures were continuously monitored to quantify the power loss and the heat evacuation for each lubricant tested. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
Thrust ball bearings lubricated with several different greases were tested on a modified Four-Ball Machine, where the Four-Ball arrangement was replaced by a bearing assembly. The friction torque and operating temperatures in a thrust ball bearing were measured during the tests. At the end of each test a grease sample was analyzed through ferrographic techniques in order to quantify and evaluate bearing wear. A rolling bearing friction torque model was used and the coefficient of friction in full film lubrication was determined for each grease, depending on the operating conditions. The experimental results obtained showed that grease formulation had a very significant influence on friction torque and operating temperature. The friction torque depends on the viscosity of the grease base oil, on its nature (mineral, ester, PAO, etc.), on the coefficient of friction in full film conditions, but also on the interaction between grease thickener and base oil, which affected contact replenishment and contact starvation, and thus influenced the friction torque.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Resumo Objectivos: Avaliação da Tosse em doentes com Doença Pulmonar Obstrutiva Crónica (DPOC). Identificar e determinar a relação dos factores preditivos que contribuem para a deterioração da capacidade de tosse nestes indivíduos. Tipo de estudo: Estudo observacional descritivo de natureza transversal. Definição dos casos: Os critérios de diagnóstico da DPOC são o quadro clínico e o Gold standard para diagnóstico da DPOC – a espirometria. População-alvo: Todos os utentes com patologia primária de DPOC diagnosticada que se desloquem ao serviço de função respiratória do Hospital de Viseu, para realizar provas. Método de Amostragem: Foi utilizada uma amostra aleatória constituída por todos os indivíduos, que cumpriram os critérios de inclusão, conscientes e colaborantes, que aceitaram participar neste estudo. Dimensão da amostra: Uma amostra de 55 indivíduos que se deslocaram ao serviço de função respiratória, entre Janeiro e Junho de 2009, para realizar provas de função respiratória. Condução do estudo: Os utentes que aceitaram participar neste estudo foram sujeitos a um questionário de dados clínicos e realizaram 5 testes: índice de massa corporal (IMC), estudo funcional respiratório e gasometria arterial, avaliação da força dos músculos respiratórios (PImax e PEmax) e avaliação do débito máximo da tosse (Peak Cough Flow). Análise estatística: Foram obtidos dados caracterizadores da amostra em estudo, sendo posteriormente correlacionado o valor de débito máximo da tosse (Peak Cough Flow) com os resultados obtidos para as avaliações do IMC, estudo funcional respiratório, PImax e PEmax, gasometria, avaliação da capacidade de Tosse e número de internamentos no último ano por agudização da DPOC. Tendo sido encontrados os valores de correlação entre o Peak Cough Flow e os restantes parâmetros. Resultados: Após análise dos resultados, foram obtidos os valores de Peak Cough Flow para a população com DPOC e verificou-se valores diminuídos em comparação com os valores normais da população, tendo-se verificado maiores valores de PCF em indivíduos do sexo masculino, em comparação aos valores do sexo feminino. Foi analisada a relação entre o PCF e a idade, peso, altura e IMC, não tendo sido encontrada relação, dado que a tosse não apresenta uma variação segundo os valores antropométricos, tal como a relação com os valores espirométricos. Quanto aos parâmetros funcionais respiratórios foram analisadas as relações com o PCF. Verificou-se relações significativas entre o PCF e o FEV1, a FVC, o PEF, apresentando uma relação positiva, onde maiores valores destes parâmetros estão correlacionados com maiores picos de tosse. Quanto a RAW e RV, o PCF apresenta uma relação negativa, onde uma maior resistência da via aérea ou doentes mais hiperinsuflados leva a menores valores de PCF. Por outro lado não foi encontrada relação entre o PCF e a FRC e o TLC. Quanto à força dos músculos respiratórios, verificou-se relação significativa com o PImax e a PEmax em que a fraqueza ao nível dos músculos respiratórios contribuem para um menor valor de PCF. Relativamente aos valores da gasometria arterial, verificou-se relação entre o PCF e a PaO2 de forma positiva, em que doentes hipoxémicos apresentam menores valores de tosse, e a PaCO2, de forma negativa, em que os doentes hipercápnicos apresentam menores valores de PCF tendo sido verificada relação entre o PCF e o pH e sO2. Quanto à relação entre o número de internamentos por agudização da DPOC no último ano e o PCF verificou-se uma relação significativa, onde um menor valor de PCF contribui para uma maior taxa de internamento por agudização da DPOC. Conclusão: Este conjunto de conclusões corrobora a hipótese inicialmente formulada, de que o Peak Cough Flow se encontra diminuído nos indivíduos com Doença Pulmonar Obstrutiva Crónica onde a variação do PCF se encontra directamente relacionada com os parâmetros funcionais respiratórios, com a força dos músculos respiratórios e com os valores de gasometria arterial. ABSTRACT: Aims: Cough evaluation in Chronic Obstructive Pulmonary Disease (COPD) patients. Identify and determine the relation of the predictive factors that contribute to the cough capacity degradation in this type of patients. Type of study: Descriptive observational study of transversal nature. Case definition: The COPD diagnosis criteria are the clinical presentation and the gold standard to the COPD diagnosis- the Spirometry. Target Population: Every patients, with primary pathology of COPD diagnosed, who went to the respiratory function service of Viseu hospital to perform tests. Sampling Method: It was used a random sample constituted by all the, conscious and cooperating individuals, who complied with the inclusion criteria and who accepted to make part of this study. Sample size: A sample of 55 individuals that went to the respiratory function service between January and June 2009 to perform respiratory function tests. Study: The patients who accepted to make part of this study were submitted to a clinical data questionary and performed 5 tests: body mass index (BMI), respiratory functional study, arterial blood gas level, evaluation of respiratory muscles strength (maximal inspiratory pressure (MIP) and maximum expiratory pressure (MEP)), and Peak Cough Flow evaluation. Statistic Analysis: Were obtained characterizing data of the sample in study, and later correlated the value of the Peak Cough Flow with the results from the evaluation of the body mass index (BMI), the respiratory functional study the MIP and MEP, the arterial blood gas level and also with the ability to cough evaluation and the number of hospitalizations in the last year for COPD exacerbations. The values of correlation between the Peak Cough Flow and the other parameters were found. Results: After analyzing the results, were obtained the values of Peak Cough Flow for the population with COPD. There were decreased values compared with the population normal values, having been found higher values of PCF in males compared to female values. It was analyzed the relation between the PCF and the age, weight, height and BMI but no relation was found on account of the fact that the cough does not show a variation according to anthropometric parameters, such as the relation with spirometric values. As for the respiratory functional parameters were analyzed relations with the PCF. There were significant relations between the PCF and FEV1, the FVC, the PEF, presenting a positive relation, where higher values of these parameters are correlated with higher incidence of cough. Concerning the RAW and RV, the PCF has a negative relation, in which a higher airway resistance or in more hyperinflated patients, leads to lower values of PCF. On the other hand no correlation was found between the PCF and the FRC and TLC. Regarding the respiratory muscle strength, there was a significant relation with the MIP and MEP, in which the weakness at the level of respiratory muscles contribute to a lower value of PCF. For values of arterial blood gas level, there was no relation between the PCF and PaO2, in a positive way, in which patients with hypoxemia present lower values of cough, and PaCO2, in a negative way in which hypercapnic patients had lower values of PCF, having being founded a relation between the PCF and the pH and sO2. As for the relation between the number of hospitalizations for COPD exacerbation in the last year and the PCF was found a significant relation, in which a smaller value of PCF contributes to a higher rate of hospitalization for COPD exacerbation. Conclusion: This set of findings supports the hypothesis first formulated that Peak Cough Flow is decreased in individuals with Chronic Obstructive Pulmonary Disease, in which the variation of the PCF is directly related to the respiratory function parameters, the strength of respiratory muscles and the values of arterial blood gases.
Resumo:
The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.
Resumo:
Terror Management Theory (TMT) suggests that human beings battle to protect ourselves from the potential terror resulting from the juxtaposition of our need for selfpreservation and our unique human ability to realize that we cannot avoid death. Over 150 studies have shown that when people are primed with the awareness of mortality they grasp onto their cultural world view more tenaciously than when they are primed with another unpleasant stimulus (i.e., show "cultural world view defense"). Applying the principles ofTMT, the first purpose of the present research was to examine whether the amount of peak experiences reduce the tendency to show cultural world view defense (an indicator of unconscious death fear) after a death prime. The second purpose was to examine a new model of implicit spirituality, by testing proposed relationships between implicit spirituality, peak experiences and intrinsic religiosity, and by testing whether peak experiences and/or intrinsic religiosity mediate the relationship between implicit spirituality and conscious and/or unconscious death fears. Skydivers were chosen as the primary participants for this research because of their unique characteristics in the context of TMT research. Previous research suggests that veteran skydivers have peak experiences as they skydive, and I assumed that their peak experiences would not be influenced by intrinsic religious beliefs. Novice skydivers may have their implicit spirituality brought forth because of their proximity to possible death. The willingness of both groups to place themselves close to death allowed their reactions to unconscious and conscious death fears to be assessed in a real setting. Novice skydivers' proximity to death made them an ideal group to study to see whether intrinsic religiosity mediated the relationship between their implicit spirituality and conscious and/or unconscious death fears. One hundred and twenty-five people participated in this research: 38 veteran and 46 novice skydivers, as well as 41 people who accompanied them to the drop zone. Of these, 23 veterans, 19 novices, and 22 friends returned a follow-up packet of questionnaires three weeks later. As expected, the veterans' unconscious death fear scores remained stable from pre-jump to post-jump (after the death prime), and three weeks later, whereas the novices' scores increased, but only marginally. As predicted, the novice skydivers' implicit spirituality was significantly higher than the veterans' and was negatively correlated with their conscious death fear, which was not mediated by their intrinsic religiosity. Only the novices' follow-up (trait) implicit spirituality correlated negatively with their pre-jump unconscious death fear. Among both groups of skydivers, there were significant relationships between implicit spirituality and peak experiences, and although the novices were significantly higher on peak experiences after the jump, peak experiences did not mediate the relationship between implicit spirituality and unconscious death fear for either group. In both groups follow-up intrinsic religiosity correlated with implicit spirituality. Peak experiences and intrinsic religiosity were not related with one another, suggesting that these are different ways of accessing an implicit spirituality. Results imply that implicit spirituality was brought forth (in the case of novice skydivers who were consciously close to death) and can be accessed through both peak experiences and intrinsic religiosity.
Resumo:
Regulatory light chain (RLC) phosphorylation in fast twitch muscle is catalyzed by skeletal myosin light chain kinase (skMLCK), a reaction known to increase muscle force, work, and power. The purpose of this study was to explore the contribution of RLC phosphorylation on the power of mouse fast muscle during high frequency (100 Hz) concentric contractions. To determine peak power shortening ramps (1.05 to 0.90 Lo) were applied to Wildtype (WT) and skMLCK knockout (skMLCK-/-) EDL muscles at a range of shortening velocities between 0.05-0.65 of maximal shortening velocity (Vmax), before and after a conditioning stimulus (CS). As a result, mean power was increased to 1.28 ± 0.05 and 1.11 ± .05 of pre-CS values, when collapsed for shortening velocity in WT and skMLCK-/-, respectively (n = 10). In addition, fitting each data set to a second order polynomial revealed that WT mice had significantly higher peak power output (27.67 ± 1.12 W/ kg-1) than skMLCK-/- (25.97 ± 1.02 W/ kg-1), (p < .05). No significant differences in optimal velocity for peak power were found between conditions and genotypes (p > .05). Analysis with Urea Glycerol PAGE determined that RLC phosphate content had been elevated in WT muscles from 8 to 63 % while minimal changes were observed in skMLCK-/- muscles: 3 and 8 %, respectively. Therefore, the lack of stimulation induced increase in RLC phosphate content resulted in a ~40 % smaller enhancement of mean power in skMLCK-/-. The increase in power output in WT mice suggests that RLC phosphorylation is a major potentiating component required for achieving peak muscle performance during brief high frequency concentric contractions.
Resumo:
UANL
Resumo:
Laser-induced plasma generated from a silver target under partial vacuum conditions using the fundamental output of nanosecond duration from a pulsed Nd:yttrium aluminum garnet laser is studied using a Langmuir probe. The time of flight measurements show a clear twin peak distribution in the temporal profile of electron emission. The first peak has almost the same duration as the laser pulse while the second lasts for several microseconds. The prompt electrons are energetic enough ('60 eV) to ionize the ambient gas molecules or atoms. The use of prompt electron pulses as sources for electron impact excitation is demonstrated by taking nitrogen, carbon dioxide, and argon as ambient gases.
Resumo:
Many approaches to force control have assumed the ability to command torques accurately. Concurrently, much research has been devoted to developing accurate torque actuation schemes. Often, torque sensors have been utilized to close a feedback loop around output torque. In this paper, the torque control of a brushless motor is investigated through: the design, construction, and utilization of a joint torque sensor for feedback control; and the development and implementation of techniques for phase current based feedforeward torque control. It is concluded that simply closing a torque loop is no longer necessarily the best alternative since reasonably accurate current based torque control is achievable.
Resumo:
This report explores the design and control issues associated with a brushless actuator capable of achieving extremely high torque accuracy. Models of several different motor - sensor configurations were studied to determine dynamic characteristics. A reaction torque sensor fixed to the motor stator was implemented to decouple the transmission dynamics from the sensor. This resulted in a compact actuator with higher bandwidth and precision than could be obtained with an inline or joint sensor. Testing demonstrated that closed-loop torque accuracy was within 0.1%, and the mechanical bandwidth approached 300 Hz.
Resumo:
This thesis details the development of a model of a seven degree of freedom manipulator for position control. Then, it goes on to discuss the design and construction of a the PHD, a robot built to serve two purposes: first, to perform research on joint torque control schemes, and second, to determine the important dynamic characteristics of the Harmonic Drive. The PHD, is a planar, three degree of freedom arm with torque sensors integral to each joint. Preliminary testing has shown that a simple linear spring model of the Harmonic Drive's flexibility is suitable in many situations.
Resumo:
This report describes development of micro-fabricated piezoelectric ultrasonic motors and bulk-ceramic piezoelectric ultrasonic motors. Ultrasonic motors offer the advantage of low speed, high torque operation without the need for gears. They can be made compact and lightweight and provide a holding torque in the absence of applied power, due to the traveling wave frictional coupling mechanism between the rotor and the stator. This report covers modeling, simulation, fabrication and testing of ultrasonic motors. Design of experiments methods were also utilized to find optimal motor parameters. A suite of 8 mm diameter x 3 mm tall motors were machined for these studies and maximum stall torques as large as 10^(- 3) Nm, maximum no-load speeds of 1710 rpm and peak power outputs of 27 mW were realized. Aditionally, this report describes the implementation of a microfabricated ultrasonic motor using thin-film lead zirconate titanate. In a joint project with the Pennsylvania State University Materials Research Laboratory and MIT Lincoln Laboratory, 2 mm and 5 mm diameter stator structures were fabricated on 1 micron thick silicon nitride membranes. Small glass lenses placed down on top spun at 100-300 rpm with 4 V excitation at 90 kHz. The large power densities and stall torques of these piezoelectric ultrasonic motors offer tremendous promis for integrated machines: complete intelligent, electro-mechanical autonomous systems mass-produced in a single fabrication process.