973 resultados para Oxford Readings in Aristophanes


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Com o objetivo de contribuir para a democratização da memória escolar no Brasil, em especial, da história da formação de professores primários nas décadas finais do século XIX brasileiro (caso paulista) e francês, apresentam-se, resultados de pesquisas de doutorado, desenvolvidas mediante abordagem histórica centrada na análise da configuração textual de três documentos: 1. lista de livros da caixa nº 1 adquirida por Paulo Bourroul, Diretor da Escola Normal de São Paulo (1882-1884), quando de sua viagem à Paris em 1883; 2. lista de livros contidos no relatório de José Estacio Corrêa de Sá e Benevides, Diretor interino da Escola Normal de São Paulo em 1884; 3. Catalogue des bibliothèques des Écoles Normales (1887), publicados pelo Ministro da Instrução Pública e de Belas Artes da França, Jules Ferry. Constatou-se importantes aspectos da cultura escolar relativos ao “ensinar normalistas a ensinar” leitura e escrita decorrentes das transferências culturais e de modelos pedagógicos na relação/representação Brasil-França.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To examine whether high levels of self-efficacy for problem-focused coping were significantly related to several resting BP measures in spousal Alzheimer's disease caregivers. Design. Cross-sectional. Methods. Participants included 100 older caregivers (mean age = 73.8 ± 8.14 years) providing in home care for a spouse with Alzheimer's disease. All participants completed a 13-item short form of the Coping Self-Efficacy Scale and underwent an in-home assessment where a visiting nurse took the average of three serial BP readings. Multiple regression was used to examine the relationship between self-efficacy and mean arterial pressure (MAP), systolic BP (SBP), diastolic BP (DBP), and pulse pressure (PP) after controlling for age, gender, smoking history, body mass index, the care recipient's clinical dementia rating, diabetes, alcohol use, and the use of antihypertensive medications. Results. Overall, high levels of self-efficacy for problem-focused coping were associated with lower MAP, SBP, and PP. Self-efficacy for problem-focused coping was marginally associated with resting DBP, but not significant. In addition, we conducted secondary analyses of the other two self-efficacy scales to explore the relationship between each dimension and MAP. We found that there were no significant relationships found between MAP and self-efficacy for stopping unpleasant thoughts/emotions or self-efficacy for getting social support. Conclusions. The present study adds to the current body of literature by illustrating the possibility that higher self-efficacy can have physiological advantages, perhaps by buffering chronic stress's impact on resting BP. Another contribution of the current study is its attempt to understand the role of each individual component of self-efficacy. These findings invite future research to investigate whether caregivers might experience cardiovascular benefits from interventions aimed at enhancing self-efficacy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To assess influence of durotomy on spinal cord blood flow (SCBF) in chondrodystrophic dogs with thoracolumbar disk extrusion. STUDY DESIGN: Prospective cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n = 11). METHODS: Diagnosis was based on neurologic signs, magnetic resonance imaging (MRI) findings, and surgical confirmation. Regional SCBF was measured 3 times intraoperatively by laser-Doppler flowmetry: (1) before surgical decompression; (2) immediately after decompression by hemilaminectomy-durotomy; and (3) after 15 minutes of lesion lavage. A standardized hemilaminectomy and durotomy performed by the same neurosurgeon, was used to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found immediately after spinal cord decompression and durotomy in dogs but SCBF returned to previous levels or lower after 15 minutes of lavage. Changes in SCBF were not associated with duration of clinical signs; neurologic status, degree of spinal cord compression, or signal intensity changes as assessed by MRI. CONCLUSION: Durotomy does not increase SCBF in dogs with disk extrusion associated spinal cord compression.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. MATERIAL AND METHODS: This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. RESULTS: 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. DISCUSSION: The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To assess the bleeding on probing (BOP) tendency and periodontal probe penetration when applying various probing forces at implant sites in patients with a high standard of oral hygiene with well-maintained peri-implant tissues. MATERIAL AND METHODS: Seventeen healthy patients with excellent oral hygiene in a maintenance program after having been treated for periodontitis or gingivitis were recruited. Missing teeth had been replaced using oral implants. The BOP and probing depth (PPD) were assessed at the mid-buccal, mid-oral, mesial and distal aspects of the buccal surfaces of each implant. Moreover, contralateral teeth were designated and assessed for BOP and PPD in the same locations and at the same observation visits. At each visit, implants and contralateral teeth were randomly assigned to one of the standardized probing forces (0.15 or 0.25 N). The second probing force was applied at the repetition of the examination 7 days later. RESULTS: Increasing the probing pressure by 0.1 N from 0.15 N resulted in an increase of BOP percentage by 13.7% and 6.6% for implants and contralateral teeth, respectively. There appeared to be a significant difference of the mean BOP percentage at implant and tooth sites when a probing pressure of 0.25 N was applied. A significantly deeper mean PPD at implant sites compared with tooth sites was found irrespective of the probing pressure applied. CONCLUSIONS: The results of the present study demonstrated that 0.15 N might represent the threshold pressure to be applied to avoid false positive BOP readings around oral implants. Hence, probing around implants demonstrated a higher sensitivity compared with probing around teeth.