965 resultados para Objective measurement
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Background It is noteworthy that there is a clear clinical, epidemiological and pathophysiological association between upper and lower airway inflammation in rhinitis and asthma. Objective The aim of this study was to compare the eosinophil counts in induced sputum and nasal lavage fluids in asthma, checking their association and the accuracy of nasal eosinophilia as a predictor of sputum eosinophilia by a cross-sectional study. Methods The clinical evaluation, asthma control questionnaire (ACQ), pre- and post-bronchodilator spirometry, nasal and sputum sample was performed. The nasal eosinophilia was analysed by a receiver operating curve and logistic regression model. Results In 140 adults, the post-bronchodilator forced expiratory volume in 1 s (FEV(1)) did not differ between patients with or without sputum eosinophilia (0.18). After adjusted for upper airway symptoms, age, ACQ score and post-bronchodilator FEV(1), sputum eosinophilia was associated with 52 times increase in odds of nasal eosinophilia, whereas each 1% increase in bronchodilator response was associated with 7% increase in odds of nasal eosinophilia. Conclusion This study brings further evidence that upper airway diseases are an important component of the asthma syndrome. Furthermore, monitoring of nasal eosinophilia by quantitative cytology may be useful as a surrogate of sputum cytology in as a component of composite measurement for determining airway inflammation.
Resumo:
OBJECTIVE To evaluate the effect of the environment and the observer on the measurement of blood pressure (BP) as well as to compare home BP (HBP) and ambulatory BP (ABP) measurements in the diagnosis of white coat hypertension (WCH) and masked hypertension (MH) in children and adolescents with hypertension (HT). METHODS BP of 40 patients with HT (75% of which had secondary HT and were on antihypertensive medication), mean age 12.1 years was evaluated through casual measurements at the clinic and at the HT unit, HBP for 14 days with the OMRON HEM 705 CP monitor (Omron, Tokyo, Japan) and ABP performed with SPACELABS 90207 (Spacelabs, Redmond, WA), for 24 h. RESULTS HT was diagnosed at the doctor`s office by ABP and HBP in 30/40, 27/40, and 31/40 patients, respectively. Based on office BP and ABP, 60% of patients were normotensive, 17.5% HT, 7.5% had WCH, and 15% had MH, whereas based on office BP and HBP 65, 12.5, 10, and 12.5% of patients were classified according to these diagnoses, respectively. There was considerable diagnostic agreement of HT by ABP and HBP (McNemar test, P < 0.01) (kappa = 0.56). CONCLUSION In hypertensive children and adolescents, HBP and ABP present comparable results. HBP appears to be a useful diagnostic test for the detection of MH and WCH in pediatric patients.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We have examined MC1R variant allele frequencies in the general population of South East Queensland and in a collection of adolescent dizygotic and monozygotic twins and family members to define statistical associations with hair and skin color, freckling, and mole count. Results of these studies are consistent with a linear recessive allelic model with multiplicative penetrance in the inheritance of red hair. Four alleles, D84E, R151C, R160W, and D294H, are strongly associated with red hair and fair skin with multinomial regression analysis showing odds ratios of 63, 118, 50, and 94, respectively. An additional three low-penetrance alleles V60L, V92M, and R163Q have odds ratios 6, 5, and 2 relative to the wild-type allele. To address the cellular effects of MC1R variant alleles in signal transduction, we expressed these receptors in permanently transfected HEK293 cells. Measurement of receptor activity via induction of a cAMP-responsive luciferase reporter gene found that the R151C and R160W receptors were active in the presence of NDP-MSH ligand, but at much reduced levels compared with that seen with the wild-type receptor. The ability to stimulate phosphorylation of the cAMP response element binding protein (CREB) transcription factor was also apparent in all stimulated MC1R variant allele-expressing HEK293 cell extracts as assessed by immunoblotting. In contrast, human melanoma cell lines showed wide variation in the their ability to undergo cAMP-mediated CREB phosphorylation. Culture of human melanocytes of known MC1R genotype may provide the best experimental approach to examine the functional consequences for each MC1R variant allele. With this objective, we have established more than 300 melanocyte cell strains of defined MC1R genotype.
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Homeopathy has been used for more than two hundred years to treat chronic disease using various approaches in a wide range of diseases. However, for acute disease and critical illness, application has been limited by inadequate training of homeopathic physicians and the small number of pertinent clinical studies. In view of the difficulty of practising homeopathy in Intensive Care Units (ICU), a protocol was developed to facilitate description of objective homeopathic symptoms with a ranking of symptoms appropriate for these situations (Protocol for Objective Homeopathic Semiology). Examples of favorable results with individualized homeopathic treatments for a series of cases of Systemic Inflammatory Response Syndrome (sepsis) are described. Homeopathy (2008) 97, 206-213.
Resumo:
Objective: The aim of the study was to evaluate clinical and laboratorial features of 1234 patients with different etiologies of hyper-prolactinemia, as well as the response of 388 patients with prolactinomas to dopamine agonists. Design, setting, and patients: A total of 1234 hyperprolactinemic patients from 10 Brazilian endocrine centers were enrolled in this retrospective study. Main outcome measure: PRL measurement, thyroid function tests, and screening for macroprolactin were conducted. Results: Patients were subdivided as follows: 56.2% had prolactinomas, 14.5% drug-induced hyperprolactinemia, 9.3% macroprolactinemia, 6.6% non-functioning pituitary adenomas, 6.3% primary hypothyroidism, 3.6% idiopathic hyperprolactinemia, and 3.2% acromegaly. Clinical manifestations were similar irrespective of the etiology of the hyperprolactinemia. The highest PRL levels were observed in patients with prolactinomas but there was a great overlap in PRL values between all groups. However, PRL>500 ng/ml allowed a clear distinction between prolactinomas and the other etiologies. Cabergoline (CAB) was more effective than bromocriptine (BCR) in normalizing PRL levels (81.9% vs 67.1%, p<0.0001) and in inducing significant tumor shrinkage and complete disappearance of tumor mass. Drug resistance was observed in 10% of patients treated with CAB and in 18.4% of those that used BCR (p=0.0006). Side-effects and intolerance were also more common in BCR-treated patients. Conclusion: Prolactinomas, drug-induced hyperprolactinemia, and macroprolactinemia were the 3 most common causes of hyperprolactinemia. Although PRL levels could not reliably define the etiology of hyperprolactinemia, PRL values >500 ng/ml were exclusively seen in patients with prolactinomas. CAB was significantly more effective than BCR in terms of prolactin normalization, tumor shrinkage, and tolerability.
Resumo:
Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.