988 resultados para New York (N.Y.). Board of Education. Division of Reference and Research.
Resumo:
Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.
Resumo:
Report on a review of certain expenditures made by the Iowa Department of Public Health, including the Iowa Board of Pharmacy, the Iowa Dental Board, the Iowa Board of Medicine, and the Iowa Board of Nursing, from July 1, 2011 through August 31, 2014
Resumo:
Characterizing Propionibacterium freudenreichii ssp. shermanii JS and Lactobacillus rhamnosus LC705 as a new probiotic combination: basic properties of JS and pilot in vivo assessment of the combination Each candidate probiotic strain has to have the documentation for the proper identification with current molecular tools, for the biological properties, for the safety aspects and for the health benefits in human trials if the intention is to apply the strain as health promoting culture in the commercial applications. No generalization based on species properties of an existing probiotic are valid for any novel strain, as strain specific differences appear e.g. in the resistance to GI tract conditions and in health promoting benefits (Madsen, 2006). The strain evaluation based on individual strain specific probiotic characteristics is therefore the first key action for the selection of the new probiotic candidate. The ultimate goal in the selection of the probiotic strain is to provide adequate amounts of active, living cells for the application and to guarantee that the cells are physiologically strong enough to survive and be biologically active in the adverse environmental conditions in the product and in GI tract of the host. The in vivo intervention studies are expensive and time consuming; therefore it is not rational to test all the possible candidates in vivo. Thus, the proper in vitro studies are helping to eliminate strains which are unlikely to perform well in vivo. The aims of this study were to characterize the strains of Propionibacterium freudenreichii ssp. shermanii JS and Lactobacillus rhamnosus LC705, both used for decades as cheese starter cultures, for their technological and possible probiotic functionality applied in a combined culture. The in vitro studies of Propionibacterium freudenreichii ssp. shermanii JS focused on the monitoring of the viability rates during the acid and bile treatments and on the safety aspects such as antibiotic susceptibility and adhesion. The studies with the combination of the strains JS and LC705 administered in fruit juices monitored the survival of the strains JS and LC705 during the GI transit and their effect on gut wellbeing properties measured as relief of constipation. In addition, safety parameters such as side effects and some peripheral immune parameters were assessed. Separately, the combination of P. freudenreichii ssp. shermanii JS and Lactobacillus rhamnosus LC705 was evaluated from the technological point of view as a bioprotective culture in fermented foods and wheat bread applications. In this study, the role ofP. freudenreichii ssp. shermanii JS as a candidate probiotic culture alone and in a combination with L. rhamnosus LC705 was demonstrated. Both strains were transiently recovered in high numbers in fecal samples of healthy adults during the consumption period. The good survival through the GI transit was proven for both strains with a recovery rate from 70 to 80% for the JS strain and from 40 to 60% for the LC705 strain from the daily dose of 10 log10 CFU. The good survival was shown from the consumption of fruit juices which do not provide similar matrix protection for the cells as milk based products. The strain JS did not pose
Resumo:
Best corporate governance practices published in the primers of Brazilian Securities and Exchange Commission and the Brazilian Corporate Governance Institute promote board independence as much as possible, as a way to increase the effectiveness of governance mechanism (Sanzovo, 2010). Therefore, this paper aims at understanding if what the managerial literature portraits as being self-evident - stricter governance, better performance - can be observed in actual evidence. The question answered is: do companies with a stricter control and monitoring system perform better than others? The method applied in this paper consists on comparing 116 companies in respect to the their independence level between top management team and board directors– being that measured by four parameters, namely, the percentage of independent outsiders in the board, the separation of CEO and chairman, the adoption of contingent compensation and the percentage of institutional investors in the ownership structure – and their financial return measured in terms return on assets (ROA) from the latest Quarterly Earnings release of 2012. From the 534 companies listed in the Stock Exchange of Sao Paulo – Bovespa – 116 were selected due to their level of corporate governance. The title “Novo Mercado” refers to the superior level of governance level within companies listed in Bovespa, as they have to follow specific criteria to assure shareholders ´protection (BM&F, 2011). Regression analyses were conducted in order to reveal the correlation level between two selected variables. The results from the regression analysis were the following: the correlation between each parameter and ROA was 10.26%; the second regression analysis conducted measured the correlation between the independence level of top management team vis-à-vis board directors – namely, CEO relative power - and ROA, leading to a multiple R of 5.45%. Understanding that the scale is a simplification of the reality, the second part of the analysis transforms all the four parameters into dummy variables, excluding what could be called as an arbitrary scale. The ultimate result from this paper led to a multiple R of 28.44%, which implies that the combination of the variables are still not enough to translate the complex reality of organizations. Nonetheless, an important finding can be taken from this paper: two variables (percentage of outside directors and percentage of institutional investor ownership) are significant in the regression, with p-value lower than 10% and with negative coefficients. In other words, counter affirming what the literature very often portraits as being self-evident – stricter governance leads to higher performance – this paper has provided evidences to believe that the increase in the formal governance structure trough outside directors in the board and ownership by institutional investor might actually lead to worse performance. The section limitations and suggestions for future researches presents some reasons explaining why, although supported by strong theoretical background, this paper faced some challenging methodological assumptions, precluding categorical statements about the level of governance – measured by four selected parameters – and the financial return in terms of financial on assets.
Resumo:
Somete a consideracion de las delegaciones las enmiendas propuestas al texto de las atribuciones de CEPAL, documento E/CN.12/850/Rev.1.
Resumo:
Presenta las atribuciones y reglamentos de la Comisión en cuanto a las reuniones, la Secretaría, las votaciones, los idiomas, los informes, etc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents methods based on Information Filters for solving matching problems with emphasis on real-time, or effectively real-time applications. Both applications discussed in this work deal with ultrasound-based rigid registration in computer-assisted orthopedic surgery. In the first application, the usual workflow of rigid registration is reformulated such that registration algorithms would iterate while the surgeon is acquiring ultrasound images of the anatomy to be operated. Using this effectively real-time approach to registration, the surgeon would then receive feedback in order to better gauge the quality of the final registration outcome. The second application considered in this paper circumvents the need to attach physical markers to bones for anatomical referencing. Experiments using anatomical objects immersed in water are performed in order to evaluate and compare the different methods presented herein, using both 2D as well as real-time 3D ultrasound.
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.
Resumo:
A new multimodal biometric database designed and acquired within the framework of the European BioSecure Network of Excellence is presented. It is comprised of more than 600 individuals acquired simultaneously in three scenarios: 1) over the Internet, 2) in an office environment with desktop PC, and 3) in indoor/outdoor environments with mobile portable hardware. The three scenarios include a common part of audio/video data. Also, signature and fingerprint data have been acquired both with desktop PC and mobile portable hardware. Additionally, hand and iris data were acquired in the second scenario using desktop PC. Acquisition has been conducted by 11 European institutions. Additional features of the BioSecure Multimodal Database (BMDB) are: two acquisition sessions, several sensors in certain modalities, balanced gender and age distributions, multimodal realistic scenarios with simple and quick tasks per modality, cross-European diversity, availability of demographic data, and compatibility with other multimodal databases. The novel acquisition conditions of the BMDB allow us to perform new challenging research and evaluation of either monomodal or multimodal biometric systems, as in the recent BioSecure Multimodal Evaluation campaign. A description of this campaign including baseline results of individual modalities from the new database is also given. The database is expected to be available for research purposes through the BioSecure Association during 2008.
Resumo:
This paper aims at the development and evaluation of a personalized insulin infusion advisory system (IIAS), able to provide real-time estimations of the appropriate insulin infusion rate for type 1 diabetes mellitus (T1DM) patients using continuous glucose monitors and insulin pumps. The system is based on a nonlinear model-predictive controller (NMPC) that uses a personalized glucose-insulin metabolism model, consisting of two compartmental models and a recurrent neural network. The model takes as input patient's information regarding meal intake, glucose measurements, and insulin infusion rates, and provides glucose predictions. The predictions are fed to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. An algorithm based on fuzzy logic has been developed for the on-line adaptation of the NMPC control parameters. The IIAS has been in silico evaluated using an appropriate simulation environment (UVa T1DM simulator). The IIAS was able to handle various meal profiles, fasting conditions, interpatient variability, intraday variation in physiological parameters, and errors in meal amount estimations.
Resumo:
Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.