969 resultados para Measuring method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 1979, a portion of the research farm was pattern tiled including the large tillage plots. This was used as an opportunity to compare tile installation methods: a conventional trenching machine (used widely prior to late 70s), and a trenchless “tile plow” machine. The tile plow inserted plastic tile using a mole approach, which is the current primary tiling method. This research showed that plow and trenching tiling methods were not significantly different and both provided adequate drainage. It also showed that water table measurements were influenced more by timing of water needs of the crop being grown and intensity of the rainfall event than tiling method. This report focuses on continued research completed on these trial plots from 2009 to 2011 measuring water table level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, by employing the threshold regression method, we estimate the average tariff equivalent of fixed costs for the use of a free trade agreement (FTA) among all existing FTAs in the world. It is estimated to be 3.2%. This global estimate serves as a reference rate in the evaluation of each FTA’s fixed costs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Agricultural cooperatives in China, known as Farmers' Professional Cooperatives (FPCs), are becoming popular and have been intensely promoted by the Chinese government to improve the economic welfare of small farmers. However, very few studies on Chinese agricultural cooperatives have measured the benefits to farmers who participate in FPCs after controlling for time-invariant attributes of farmers. This paper investigates the treatment effect of participation in a rice-producing cooperative in suburban China using propensity score matching (PSM) and difference-in-differences (DID) method. Estimated results show that no significant difference is observed between participants and non-participants of the cooperative in terms of net income from rice production when controlling for the difference in farmers' rice incomes before the treatment. In addition, there is no significant heterogeneity of the treatment effects between large and small farmers, although the probability of participation in the cooperative is significantly higher when the size of cultivated rice farmland is greater. These results indicate that the benefits of the cooperative appear to be overestimated considering the vigorous policy supports for FPCs from the Chinese government.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new and effective method for reduction of truncation errors in partial spherical near-field (SNF) measurements is proposed. The method is useful when measuring electrically large antennas, where the measurement time with the classical SNF technique is prohibitively long and an acquisition over the whole spherical surface is not practical. Therefore, to reduce the data acquisition time, partial sphere measurement is usually made, taking samples over a portion of the spherical surface in the direction of the main beam. But in this case, the radiation pattern is not known outside the measured angular sector as well as a truncation error is present in the calculated far-field pattern within this sector. The method is based on the Gerchberg-Papoulis algorithm used to extrapolate functions and it is able to extend the valid region of the calculated far-field pattern up to the whole forward hemisphere. To verify the effectiveness of the method, several examples are presented using both simulated and measured truncated near-field data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although there are numerous accurate measuring methods to determine soil moisture content in a spot, until very recently there were no precise in situ and in real time methods that were able to measure soil moisture content along a line. By means of the Distributed Fiber Optic Temperature Measurement method or DFOT, the temperature in 0.12 m intervals and long distances (up to 10,000 m) with a high time frequency and an accuracy of +0.2º C is determined. The principle of temperature measurement along a fiber optic cable is based on the thermal sensitivity of the relative intensities of backscattered photons that arise from collisions with electrons in the core of the glass fiber. A laser pulse, generated by the DTS unit, traversing a fiber optic cable will result in backscatter at two frequencies. The DTS quantifies the intensity of these backscattered photons and elapsed time between the pulse and the observed returned light. The intensity of one of the frequencies is strongly dependent on the temperature at the point where the scattering process occurred. The computed temperature is attributed to the position along the cable from which the light was reflected, computed from the time of travel for the light.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate a simple self-referenced single-shot method for simultaneously measuring two different arbitrary pulses, which can potentially be complex and also have very different wavelengths. The method is a variation of cross-correlation frequency-resolved optical gating (XFROG) that we call double-blind (DB) FROG. It involves measuring two spectrograms, both of which are obtained simultaneously in a single apparatus. DB FROG retrieves both pulses robustly by using the standard XFROG algorithm, implemented alternately on each of the traces, taking one pulse to be ?known? and solving for the other. We show both numerically and experimentally that DB FROG using a polarization-gating beam geometry works reliably and appears to have no nontrivial ambiguities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among those damage identification methods, the Wavelet Packet Energy Curvature Difference (WPECD) Method is an effective one. However, most of the existing methods rely on numerical simulation and are unverified via experiment, and very few of them have been applied to practice. In this paper, the validity of WPECD in structural damage identification is verified by a numerical example. A damage simulation experiment is taken on a real replaced girder at the Ziya River New Bridge in Cangzhou. Two damage cases are applied and the acceleration responses at the measuring points are obtained, based on which the damages are identified with the WPECD Method, and the influence of wavelet function and decomposition level is studied. The results show that the WPECD Method can identify structure damage efficiently and can be put into practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main limiting factors in the development of new magnesium (Mg) alloys with enhanced mechanical behavior is the need to use vast experimental campaigns for microstructure and property screening. For example, the influence of new alloying additions on the critical resolved shear stresses (CRSSs) is currently evaluated by a combination of macroscopic single-crystal experiments and crystal plasticity finite-element simulations (CPFEM). This time-consuming process could be considerably simplified by the introduction of high-throughput techniques for efficient property testing. The aim of this paper is to propose a new and fast, methodology for the estimation of the CRSSs of hexagonal close-packed metals which, moreover, requires small amounts of material. The proposed method, which combines instrumented nanoindentation and CPFEM modeling, determines CRSS values by comparison of the variation of hardness (H) for different grain orientations with the outcome of CPFEM. This novel approach has been validated in a rolled and annealed pure Mg sheet, whose H variation with grain orientation has been successfully predicted using a set of CRSSs taken from recent crystal plasticity simulations of single-crystal experiments. Moreover, the proposed methodology has been utilized to infer the effect of the alloying elements of an MN11 (Mg–1% Mn–1% Nd) alloy. The results support the hypothesis that selected rare earth intermetallic precipitates help to bring the CRSS values of basal and non-basal slip systems closer together, thus contributing to the reduced plastic anisotropy observed in these alloys

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first feasibility study of using dual-probe heated fiber optics with distributed temperature sensing to measure soil volumetric heat capacity and soil water content is presented. Although results using different combinations of cables demonstrate feasibility, further work is needed to gain accuracy, including a model to account for the finite dimension and the thermal influence of the probes. Implementation of the dual-probe heat-pulse (DPHP) approach for measurement of volumetric heat capacity (C) and water content (θ) with distributed temperature sensing heated fiber optic (FO) systems presents an unprecedented opportunity for environmental monitoring (e.g., simultaneous measurement at thousands of points). We applied uniform heat pulses along a FO cable and monitored the thermal response at adjacent cables. We tested the DPHP method in the laboratory using multiple FO cables at a range of spacings. The amplitude and phase shift in the heat signal with distance was found to be a function of the soil volumetric heat capacity. Estimations of C at a range of moisture contents (θ = 0.09– 0.34 m3 m−3) suggest the feasibility of measurement via responsiveness to the changes in θ, although we observed error with decreasing soil water contents (up to 26% at θ = 0.09 m3 m−3). Optimization will require further models to account for the finite radius and thermal influence of the FO cables. Although the results indicate that the method shows great promise, further study is needed to quantify the effects of soil type, cable spacing, and jacket configurations on accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Actively Heated Fiber Optic (AHFO) method is shown to be capable of measuring soil water content several times per hour at 0.25 m spacing along cables of multiple kilometers in length. AHFO is based on distributed temperature sensing (DTS) observation of the heating and cooling of a buried fiber-optic cable resulting from an electrical impulse of energy delivered from the steel cable jacket. The results presented were collected from 750 m of cable buried in three 240 m colocated transects at 30, 60, and 90 cm depths in an agricultural field under center pivot irrigation. The calibration curve relating soil water content to the thermal response of the soil to a heat pulse of 10 W m−1 for 1 min duration was developed in the lab. This calibration was found applicable to the 30 and 60 cm depth cables, while the 90 cm depth cable illustrated the challenges presented by soil heterogeneity for this technique. This method was used to map with high resolution the variability of soil water content and fluxes induced by the nonuniformity of water application at the surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dominance measuring methods are an approach for dealing with complex decision-making problems with imprecise information within multi-attribute value/utility theory. These methods are based on the computation of pairwise dominance values and exploit the information in the dominance matrix in different ways to derive measures of dominance intensity and rank the alternatives under consideration. In this paper we review dominance measuring methods proposed in the literature for dealing with imprecise information (intervals, ordinal information or fuzzy numbers) about decision-makers? preferences and their performance in comparison with other existing approaches, like SMAA and SMAA-II or Sarabando and Dias? method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders. Manual methods for estimating cortical thickness from neuroimaging data are labor intensive, requiring several days of effort by a trained anatomist. Furthermore, the highly folded nature of the cortex is problematic for manual techniques, frequently resulting in measurement errors in regions in which the cortical surface is not perpendicular to any of the cardinal axes. As a consequence, it has been impractical to obtain accurate thickness estimates for the entire cortex in individual subjects, or group statistics for patient or control populations. Here, we present an automated method for accurately measuring the thickness of the cerebral cortex across the entire brain and for generating cross-subject statistics in a coordinate system based on cortical anatomy. The intersubject standard deviation of the thickness measures is shown to be less than 0.5 mm, implying the ability to detect focal atrophy in small populations or even individual subjects. The reliability and accuracy of this new method are assessed by within-subject test–retest studies, as well as by comparison of cross-subject regional thickness measures with published values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous improvement of management and assessment processes for curricular external internships has led a group of university teachers specialised in this area to develop a mixed model of measurement that combines the verification of skill acquisition by those students choosing external internships with the satisfaction of the parties involved in that process. They included academics, educational tutors of companies and organisations and administration and services personnel in the latter category. The experience, developed within University of Alicante, has been carried out in the degrees of Business Administration and Management, Business Studies, Economics, Advertising and Public Relations, Sociology and Social Work, all part of the Faculty of Economics and Business. By designing and managing closed standardised interviews and other research tools, validated outside the centre, a system of continuous improvement and quality assurance has been created, clearly contributing to the gradual increase in the number of students with internships in this Faculty, as well as to the improvement in satisfaction, efficiency and efficacy indicators at a global level. As this experience of educational innovation has shown, the acquisition of curricular knowledge, skills, abilities and competences by the students is directly correlated with the satisfaction of those parties involved in a process that takes the student beyond the physical borders of a university campus. Ensuring the latter is a task made easier by the implementation of a mixed assessment method, combining continuous and final assessment, and characterised by its rigorousness and simple management. This report presents that model, subject in turn to a persistent and continuous control, a model all parties involved in the external internships are taking part of. Its short-term results imply an increase, estimated at 15% for the last course, in the number of students choosing curricular internships and, for the medium and long-term, a major interweaving between the academic world and its social and productive environment, both in the business and institutional areas. The potentiality of this assessment model does not lie only in the quality of its measurement tools, but also in the effects from its use in the various groups and in the actions that are carried out as a result of its implementation and which, without any doubt and as it is shown below, are the real guarantee of a continuous improvement.