951 resultados para March of Dimes Birth Defects Foundation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To study mother-to-infant emotional involvement at birth, namely factors (socio-demographics, previous life events, type of delivery, pain at childbirth, support from partner, infant characteristics, early experiences with the newborn, and mother’s mood) that interfere with the mother’s positive, negative and not clear emotions toward the newborn. Methods. The Bonding Scale (an extended Portuguese version of the ‘New Mother-to-Infant Bonding Scale’) and the Edinburgh Postnatal Depression Scale were administrated during the first after delivery days to 315 mothers recruited at Ju´lio Dinis Maternity Hospital (MJD, Porto, Portugal). Results. A worse emotional involvement with the newborn was observed when the mother was unemployed, unmarried, had less than grade 9, previous obstetrical/psychological problems or was depressed, as well as when the infant was female, had neonatal problems or was admitted in the intensive care unit. Lower total bonding results were significantly predicted when the mother was depressed and had a lower educational level; being depressed, unemployed and single predicted more negative emotions toward the infant as well. No significant differences in the mother-to-infant emotional involvement were obtained for events related to childbirth, such as type of delivery, pain and partner support, or early experiences with the newborn; these events do not predict mother’s bonding results either. Conclusion. The study results support the need for screening and supporting depressed, unemployed and single mothers, in order to prevent bonding difficulties with the newborn at birth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This study describes the prevalence, associated anomalies, and demographic characteristics of cases of multiple congenital anomalies (MCA) in 19 population-based European registries (EUROCAT) covering 959,446 births in 2004 and 2010. METHODS: EUROCAT implemented a computer algorithm for classification of congenital anomaly cases followed by manual review of potential MCA cases by geneticists. MCA cases are defined as cases with two or more major anomalies of different organ systems, excluding sequences, chromosomal and monogenic syndromes. RESULTS: The combination of an epidemiological and clinical approach for classification of cases has improved the quality and accuracy of the MCA data. Total prevalence of MCA cases was 15.8 per 10,000 births. Fetal deaths and termination of pregnancy were significantly more frequent in MCA cases compared with isolated cases (p < 0.001) and MCA cases were more frequently prenatally diagnosed (p < 0.001). Live born infants with MCA were more often born preterm (p < 0.01) and with birth weight < 2500 grams (p < 0.01). Respiratory and ear, face, and neck anomalies were the most likely to occur with other anomalies (34% and 32%) and congenital heart defects and limb anomalies were the least likely to occur with other anomalies (13%) (p < 0.01). However, due to their high prevalence, congenital heart defects were present in half of all MCA cases. Among males with MCA, the frequency of genital anomalies was significantly greater than the frequency of genital anomalies among females with MCA (p < 0.001). CONCLUSION: Although rare, MCA cases are an important public health issue, because of their severity. The EUROCAT database of MCA cases will allow future investigation on the epidemiology of these conditions and related clinical and diagnostic problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the current effectiveness of routine prenatal ultrasound screening in detecting gastroschisis and omphalocele in Europe. DESIGN: Data were collected by 19 congenital malformation registries from 11 European countries. The registries used the same epidemiological methodology and registration system. The study period was 30 months (July 1st 1996-December 31st 1998) and the total number of monitored pregnancies was 690,123. RESULTS: The sensitivity of antenatal ultrasound examination in detecting omphalocele was 75% (103/137). The mean gestational age at the first detection of an anomaly was 18 +/- 6.0 gestational weeks. The overall prenatal detection rate for gastroschisis was 83% (88/106) and the mean gestational age at diagnosis was 20 +/- 7.0 gestational weeks. Detection rates varied between registries from 25 to 100% for omphalocele and from 18 to 100% for gastroschisis. Of the 137 cases of omphalocele less than half of the cases were live births (n = 56; 41%). A high number of cases resulted in fetal deaths (n = 30; 22%) and termination of pregnancy (n = 51; 37%). Of the 106 cases of gastroschisis there were 62 (59%) live births, 13 (12%) ended with intrauterine fetal death and 31 (29%) had the pregnancies terminated. CONCLUSIONS: There is significant regional variation in detection rates in Europe reflecting different policies, equipment and the operators' experience. A high proportion of abdominal wall defects is associated with concurrent malformations, syndromes or chromosomal abnormalities, stressing the need for the introduction of repeated detailed ultrasound examination as a standard procedure. There is still a relatively high rate of elective termination of pregnancies for both defects, even in isolated cases which generally have a good prognosis after surgical repair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: Excess glucose transport to embryos during diabetic pregnancy causes congenital malformations. The early postimplantation embryo expresses the gene encoding the high-Km GLUT2 (also known as SLC2A2) glucose transporter. The hypothesis tested here is that high-Km glucose transport by GLUT2 causes malformations resulting from maternal hyperglycaemia during diabetic pregnancy. MATERIALS AND METHODS: Glut2 mRNA was assayed by RT-PCR. The Km of embryo glucose transport was determined by measuring 0.5-20 mmol/l 2-deoxy[3H]glucose transport. To test whether the GLUT2 transporter is required for neural tube defects resulting from maternal hyperglycaemia, Glut2+/- mice were crossed and transient hyperglycaemia was induced by glucose injection on day 7.5 of pregnancy. Embryos were recovered on day 10.5, and the incidence of neural tube defects in wild-type, Glut2+/- and Glut2-/- embryos was scored. RESULTS: Early postimplantation embryos expressed Glut2, and expression was unaffected by maternal diabetes. Moreover, glucose transport by these embryos showed Michaelis-Menten kinetics of 16.19 mmol/l, consistent with transport mediated by GLUT2. In pregnancies made hyperglycaemic on day 7.5, neural tube defects were significantly increased in wild-type embryos, but Glut2+/- embryos were partially protected from neural tube defects, and Glut2-/- embryos were completely protected from these defects. The frequency of occurrence of wild-type, Glut2+/- and Glut2-/- embryos suggests that the presence of Glut2 alleles confers a survival advantage in embryos before day 10.5. CONCLUSIONS/INTERPRETATIONS: High-Km glucose transport by the GLUT2 glucose transporter during organogenesis is responsible for the embryopathic effects of maternal diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European Surveillance of Congenital Anomalies (EUROCAT) network of population-based congenital anomaly registries is an important source of epidemiologic information on congenital anomalies in Europe covering live births, fetal deaths from 20 weeks gestation, and terminations of pregnancy for fetal anomaly. EUROCAT's policy is to strive for high-quality data, while ensuring consistency and transparency across all member registries. A set of 30 data quality indicators (DQIs) was developed to assess five key elements of data quality: completeness of case ascertainment, accuracy of diagnosis, completeness of information on EUROCAT variables, timeliness of data transmission, and availability of population denominator information. This article describes each of the individual DQIs and presents the output for each registry as well as the EUROCAT (unweighted) average, for 29 full member registries for 2004-2008. This information is also available on the EUROCAT website for previous years. The EUROCAT DQIs allow registries to evaluate their performance in relation to other registries and allows appropriate interpretations to be made of the data collected. The DQIs provide direction for improving data collection and ascertainment, and they allow annual assessment for monitoring continuous improvement. The DQI are constantly reviewed and refined to best document registry procedures and processes regarding data collection, to ensure appropriateness of DQI, and to ensure transparency so that the data collected can make a substantial and useful contribution to epidemiologic research on congenital anomalies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Birth defects are a major health burden. Primary prevention is at present emerging, i.e. folate supplementation. When it is not possible, as is still the case for most birth defects, research is needed to determine how an optimal provision of prenatal diagnosis and use of services can be achieved. Ultrasound scans in the midtrimester of pregnancy are now a routine part of antenatal care in most European countries. The objective of this study was to evaluate the prenatal diagnosis of congenital anomalies by fetal ultrasonographic examination across Europe. Methods: Data from 20 registries of congenital malformations in 12 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to 3 fetal scans offered, including 2 for biometric purposes and 1 for search of congenital anomalies, the anomaly scan. Results: There were 8,126 cases with congenital anomalies with an overall prenatal detection rate of 44.3%. Termination of pregnancy was performed in 1,657 cases (21.8%). There was significant variation in the prenatal detection rate between regions with the lowest detection rate in registries of countries without routine fetal screening (Denmark and The Netherlands) and the highest detection rate in registries of countries with at least 1 anomaly scan (France, Germany, Italy, Spain, UK). However, there were large variations among the registries with a high detection rate. There were significant differences in the prenatal detection rate and proportion of induced abortions between isolated anomalies and associated anomalies (chromosomal aberrations, recognized syndromes, and multiple without chromosomal aberrations or recognized syndromes). Conclusions: Prenatal detection rate of congenital anomalies by fetal scan varies significantly between registries of European countries even with the same screening policy. Prenatal detection of congenital anomalies is significantly higher when associated malformations are present. The rate of induced abortions varies between registries of countries even with the same detection rate of congenital anomalies. The variation described may be due to cultural and policy differences. Copyright 2002 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: One course of antenatal corticosteroids reduces the risk of respiratory distress syndrome and neonatal death. Weekly doses given to women who remain undelivered after a single course may have benefits (less respiratory morbidity) or cause harm (reduced growth in utero). We aimed to find out whether multiple courses of antenatal corticosteroids would reduce neonatal morbidity and mortality without adversely affecting fetal growth. METHODS: 1858 women at 25-32 weeks' gestation who remained undelivered 14-21 days after an initial course of antenatal corticosteroids and continued to be at high risk of preterm birth were randomly assigned to multiple courses of antenatal corticosteroids (n=937) or placebo (n=921), every 14 days until week 33 or delivery, whichever came first. The primary outcome was a composite of perinatal or neonatal mortality, severe respiratory distress syndrome, intraventricular haemorrhage (grade III or IV), periventricular leucomalacia, bronchopulmonary dysplasia, or necrotising enterocolitis. Analysis was by intention to treat. All patients and caregivers were unaware of the treatment given. This trial is registered as number ISRCTN2654148. FINDINGS: Infants exposed to multiple courses of antenatal corticosteroids had similar morbidity and mortality to those exposed to placebo (150 [12.9%] vs 143 [12.5%]). Those receiving multiple doses of corticosteroids also weighed less at birth than those exposed to placebo (2216 g vs 2330 g, p=0.0026), were shorter (44.5 cm vs 45.4 cm, p<0.001), and had a smaller head circumference (31.1 cm vs 31.7 cm, p<0.001). INTERPRETATION: Multiple courses of antenatal corticosteroids, every 14 days, do not improve preterm-birth outcomes, and are associated with a decreased weight, length, and head circumference at birth. Therefore, this treatment schedule is not recommended. FUNDING: Canadian Institutes of Health Research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This study determines the prevalence of Congenital Heart Defects (CHD), diagnosed prenatally or in infancy, and fetal and perinatal mortality associated with CHD in Europe. METHODS AND RESULTS: Data were extracted from the European Surveillance of Congenital Anomalies central database for 29 population-based congenital anomaly registries in 16 European countries covering 3.3 million births during the period 2000 to 2005. CHD cases (n=26 598) comprised live births, fetal deaths from 20 weeks gestation, and terminations of pregnancy for fetal anomaly (TOPFA). The average total prevalence of CHD was 8.0 per 1000 births, and live birth prevalence was 7.2 per 1000 births, varying between countries. The total prevalence of nonchromosomal CHD was 7.0 per 1000 births, of which 3.6% were perinatal deaths, 20% prenatally diagnosed, and 5.6% TOPFA. Severe nonchromosomal CHD (ie, excluding ventricular septal defects, atrial septal defects, and pulmonary valve stenosis) occurred in 2.0 per 1000 births, of which 8.1% were perinatal deaths, 40% were prenatally diagnosed, and 14% were TOPFA (TOPFA range between countries 0% to 32%). Live-born CHD associated with Down syndrome occurred in 0.5 per 1000 births, with > 4-fold variation between countries. CONCLUSION: Annually in the European Union, we estimate 36 000 children are live born with CHD and 3000 who are diagnosed with CHD die as a TOFPA, late fetal death, or early neonatal death. Investing in primary prevention and pathogenetic research is essential to reduce this burden, as well as continuing to improve cardiac services from in utero to adulthood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the reciprocal influence between educational decisions and the timing of first births, using the Family and Fertility Surveys of France and West Germany. Since these two processes are potentially endogenous, we modelled them jointly, using event history models. We hypothesise that the reciprocal impact of educational and fertility careers, as well as the impact of the common determinants of both processes, are gender specific and context specific.The results show a significant endogeneity for women and men in both countries. This endogeneity is stronger for women than for men, while no substantial differences are found between the two countries. Removing this shared and unobserved heterogeneity, the results show a stronger reciprocal impact between the processes for women than for men. A similar impact of being enrolled in education on first birth in both countries is found, while the effect of the birth (and especially of the pregnancy) of the first child on terminating one’s education appeared to be more marked in West Gernany than in France.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: A single course of antenatal corticosteroids (ACS) is associated with a reduction in respiratory distress syndrome and neonatal death. Multiple Courses of Antenatal Corticosteroids Study (MACS), a study involving 1858 women, was a multicentre randomized placebo-controlled trial of multiple courses of ACS, given every 14 days until 33+6 weeks or birth, whichever came first. The primary outcome of the study, a composite of neonatal mortality and morbidity, was similar for the multiple ACS and placebo groups (12.9% vs. 12.5%), but infants exposed to multiple courses of ACS weighed less, were shorter, and had smaller head circumferences. Thus for women who remain at increased risk of preterm birth, multiple courses of ACS (every 14 days) are not recommended. Chronic use of corticosteroids is associated with numerous side effects including weight gain and depression. The aim of this postpartum assessment was to ascertain if multiple courses of ACS were associated with maternal side effects. METHODS: Three months postpartum, women who participated in MACS were asked to complete a structured questionnaire that asked about maternal side effects of corticosteroid use during MACS and included the Edinburgh Postnatal Depression Scale. Women were also asked to evaluate their study participation. RESULTS: Of the 1858 women randomized, 1712 (92.1%) completed the postpartum questionnaire. There were no significant differences in the risk of maternal side effects between the two groups. Large numbers of women met the criteria for postpartum depression (14.1% in the ACS vs. 16.0% in the placebo group). Most women (94.1%) responded that they would participate in the trial again. CONCLUSION: In pregnancy, corticosteroids are given to women for fetal lung maturation and for the treatment of various maternal diseases. In this international multicentre randomized controlled trial, multiple courses of ACS (every 14 days) were not associated with maternal side effects, and the majority of women responded that they would participate in such a study again.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Due to patency of the arterial duct and the parallel circulation during the fetal life, coarctation remains a difficult diagnosis prenatally and even shortly after birth. Fisrtly, our study aimed to assess accuracy of a new cardiographie index based on morphologie measurements of the distal aortic arch, the Carotid-Subclavian Artery Index (CSA Index), the ratio of the distal transverse aortic arch diameter to the distance between the left carotid artery and the left subclavian artery, in detecting coarctation in newborns, infants and children, independently of other cardiac lesions. Secondly, to assess the additive value of another morphologie index in predicting coarctation, the 1/0 ratio, the ratio of isthmus to descending aorta diameter. Methods: It is a retrospective cohort study in a tertiary care children's hospital. Offline echocardiographic measurements of great vessels and aortic arch dimensions were done in 69 patients with coarctation. We calculate their CSA index, and their 1/0 ratio. Values of CSA Index and 1/0 ratio from coarctation group were compared with those from a normal local control population. Results: 69 echocardiograms from patients with coarctation were analysed. Compared with controls, patients with coarctation had a significantly lower CSA index (0.88 ±0.49 vs 2.65 ±0.82, p <0.0001) and 1/0 ratio. The same significant difference was observed, independently of age and other associated defects, even complex ones. CSA Index confirmed its good sensitivity and specificity (99% and 96% respectively). This was not improved by adding the I/D ratio. Conclusions: An abnormal CSA index is highly suggestive of coarctation independently of age, of the presence of a patent ductus arteriosus or of other cardiac defects. The addition of another anatomie index, the I/D ratio, was not helpful in our study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Healthcare professionals regularly read the summary of product characteristics (SmPC) as one of the various sources of information on the risks of drug use in women of childbearing age and during pregnancy. The aim of this article is to present an overview of the teratogenic potential of various antiepileptic drugs and to compare these data with the information provided by the SmPCs. METHODS: A literature search on the teratogenic risks of 19 antiepileptic agents was conducted and the results were compared with the information on the use in women of childbearing age and during pregnancy provided by the SmPCs of 38 commercial products available in Switzerland and Germany. RESULTS: The teratogenic risk is discussed in all available SmPCs. Quantification of the risk for birth defects and the numbers of documented pregnancies are mostly missing. Reproductive safety information in SmPCs showed poor concordance with risk levels reported in the literature. Recommendations concerning the need to monitor plasma levels and possibly perform dose adjustments during pregnancy to prevent treatment failure were missing in five Swiss and two German SmPCs. DISCUSSION: The information regarding use in women of childbearing age and during pregnancy provided by the SmPCs is heterogeneous and poorly reflects the current state of knowledge. Regular updates of SmPCs are warranted in order for these documents to be of reliable use for health care professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of premature birth on attachment have generally been examined from the infant's perspective. There is a lack of data concerning parental attachment representations toward a premature child. Because of the psychological stress engendered in parents confronted with a premature birth, we hypothesized that their attachment representations would be altered during the first months after the hospital discharge. Fifty families with a premature infant (25-33 gestation weeks) and a control group of 30 families with a full-term infant participated to the study. Perinatal risks were evaluated during hospitalization. To assess mothers' representations of their infant, the Working Model of the Child Interview (WMCI, Zeanah & Benoit, 1995 & Benoit, Zeanah, Parker, Nicholson, & Coolbear, 1997) were administered when their children were 6 and 18 months old. The severity of the perinatal risks was found to have an impact on the mothers' attachment representations. At six months, only 20% of the mothers of a prematurely born infant (30% at 18 months) had secure attachment representations, vs. 53% for the control group (57% at 18 months). Furthermore, mothers of low-risk premature infants more often had disengaged representations, whereas distorted representations were more frequent in the high-risk group of premature children. These findings suggest that the parental response to a premature birth is linked to the severity of postnatal risks. The fact that secure attachment representations are affected in mothers of low-risk infants just as much as they are in mothers of high-risk infants points to the need to conduct further studies aimed at evaluating whether preventive intervention for both low-risk and high-risk premature will be helpful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe the epidemiology of chromosomal and non-chromosomal cases of atrioventricular septal defects in Europe. METHODS: Data were obtained from EUROCAT, a European network of population-based registries collecting data on congenital anomalies. Data from 13 registries for the period 2000-2008 were included. RESULTS: There was a total of 993 cases of atrioventricular septal defects, with a total prevalence of 5.3 per 10,000 births (95% confidence interval 4.1 to 6.5). Of the total cases, 250 were isolated cardiac lesions, 583 were chromosomal cases, 79 had multiple anomalies, 58 had heterotaxia sequence, and 23 had a monogenic syndrome. The total prevalence of chromosomal cases was 3.1 per 10,000 (95% confidence interval 1.9 to 4.3), with a large variation between registers. Of the 993 cases, 639 cases were live births, 45 were stillbirths, and 309 were terminations of pregnancy owing to foetal anomaly. Among the groups, additional associated cardiac anomalies were most frequent in heterotaxia cases (38%) and least frequent in chromosomal cases (8%). Coarctation of the aorta was the most common associated cardiac defect. The 1-week survival rate for live births was 94%. CONCLUSION: Of all cases, three-quarters were associated with other anomalies, both chromosomal and non-chromosomal. For infants with atrioventricular septal defects and no chromosomal anomalies, cardiac defects were often more complex compared with infants with atrioventricular septal defects and a chromosomal anomaly. Clinical outcomes for atrioventricular septal defects varied between regions. The proportion of termination of pregnancy for foetal anomaly was higher for cases with multiple anomalies, chromosomal anomalies, and heterotaxia sequence.